
Slim Panel Small Ports 17" x 46" ABS plastic with gasket - (5) 3/8" extraction points - 9 pack
The Injectidry Vac-It Slim Panel Kit gives you nine long, narrow drying panels, the nipple caps to seal unused points, and a carry bag to keep them together between jobs.
Slim Panel Kit Includes
- 9 x Slim Panels - Small Ports
- 20 x SM-NIP-CAP 3/8"ID Soft (Red) Nipple Caps
- 1 x CB3 Panel Carry Bag
Easy as 1, 2, 3.... Use to dry all sorts of wet materials, such as hardwoods, headers, and plaster walls.
Simplify the setup process and significantly reduce your labour costs. After extracting excess water, simply tape around the edges, hook up the tubes (or hoses to manifolds), then hoses to the Air In (negative pressure) port of your HP System, and turn the system on. For safer drying use with the INTERCEPTOR HEPA System.
(Taping the edges is the only way to ensure a consistently good seal and minimise the trip hazard).
Where the Slim Panel Fits
At 17 × 46 inch (about 430 × 1,170 mm), the slim panel suits hallways, strips of timber floor along walls and cabinets, and other long, narrow wet areas where a wider panel will not sit flat. Each panel has five 3/8 inch extraction points along its length.
For open areas, the 8-Point Panel covers more floor per panel. For very tight spots, the Extra Slim XSP panel is 7 × 30 inch.
How It Works
Vac-It panels run under negative pressure. The HP system draws air through the panel, which pulls moisture out of the flooring or wall surface beneath it. The seal is everything: any gap at the edge lets the system draw room air instead of drawing through the wet material.
- Extract standing water first. Injectidry's Vac-It panel instructions say to run an extractor on the area for 15–20 minutes before taping.
- Injectidry recommends running a water separator in the line for the first 24 hours after extraction, to stop liquid reaching the HP blower.
- Place the panels and tape all four edges of each. Injectidry recommends preservation tape — less sticky, but strong enough to hold, and it lets you lift an edge for moisture checks.
- Run 3/8 inch HP tubing from the extraction points to a manifold, joining lengths with 3/8 inch tubing connectors.
- Connect the hose from the manifold to the Air In (negative) port of the HP system. Cap unused points with the supplied nipple caps.
- Switch on and check each panel is holding down under suction.
- Monitor with a moisture meter and record readings.
On Category 2 or 3 losses, exhaust from the HP system should be filtered. The original description above recommends Injectidry's Interceptor HEPA system. The Interceptor is not currently available to order online — ask us about filtration before you start, and follow your scope and the relevant restoration standard.
Specifications
| Brand | Injectidry |
|---|---|
| Injectidry part number | SP-SP-9 |
| Panels | 9 x Slim Panel, Small Ports |
| Panel size | 17 × 46 inch (about 430 × 1,170 mm) |
| Material | ABS plastic, with gasket |
| Extraction points | Five, 3/8 inch, per panel |
| Also in the kit | 20 x SM-NIP-CAP nipple caps; 1 x CB3 panel carry bag |
| System | Injectidry HP (negative pressure) |
| CCW SKU | IDSP-SP-9 |
Frequently Asked Questions
Will it work with a Direct-It kit?
No. Vac-It panels need the negative pressure of an HP system. Direct-It moves large volumes of air at low pressure and is not designed to pull through a sealed panel.
Do panels need to cover the whole wet area?
Not always. Injectidry's instructions say panels placed 2–3 ft (about 600–900 mm) apart will in most cases pull moisture from between them. They also recommend covering the full width of the wet area, because the flutes under the panel do not run across its width.
What tape should I use?
Injectidry recommends preservation tape. Test it on a hidden area of a finished floor first — some finishes lift with any tape.
Are the nipple caps available separately?
Yes. CCW lists 3/8 inch soft red nipple caps individually, and the CB3 carry bag on its own.
How many panels can one HP system run?
Injectidry does not publish a panel count per system. It depends on the blower, the hose and tubing lengths and the other lines on the system. Ask us with your system model.
Related Products
- Injectidry Vac-It Variety Pack
- Injectidry Vac-It 8-Point Panel
- Injectidry Vac-It Clear Panel
- Injectidry HP-PLUS Floor Drying Package
- Injectidry Parts · Structural Drying
Not sure which Vac-It panels suit the floor you are drying? Tell us the flooring type and area and we will help you choose before you order.