Protimeter replacement cable for the heavy duty hammer electrode
The lead between a BLD5055 hammer electrode and the meter.
Specifications
| Part number | BLD5055-CA |
|---|---|
| Application | Protimeter BLD5055 heavy duty hammer electrode |
Compatible meters
- Protimeter MMS3
- Protimeter MMS2
- Protimeter SurveyMaster
- Protimeter Mini, Mini C and Digital Mini
- Protimeter TimberMaster
The cable usually fails before the electrode does
On a hammer electrode the cable takes a shock load on every drive and is coiled, dragged and stood on between uses. It fails at the strain relief, and it shows up as readings that jump or drop out when the lead is moved. If a meter reads erratically only with the hammer electrode connected, suspect the cable before you suspect the meter.
The other serviceable parts are the electrode base and the BLD5296 insulated needles.
The other serviceable parts
- Insulated needles, 10 pack (BLD05296)
- Replacement hammer base (BLD5055-BA)
- Complete heavy duty hammer electrode (BLD5055)
Meters this fits
- Protimeter MMS3 — and the MMS2 it replaced
- Protimeter SurveyMaster
- Protimeter TimberMaster
- Protimeter Digital Mini
- Protimeter Mini C and Protimeter Mini
It does not fit the HygroMaster range, which measures air rather than materials, or the non-invasive Aquant and ReachMaster Pro, which take no probes at all.
Tell us which Protimeter you run and we will confirm the right part before you order.