Injectidry 5/8" OD Wall Penetrators for Direct-It Systems (Pack of 17)

Regular price $128.03

SKU:IDWP2-17

A pack of 17 Injectidry WP2 wall penetrators: the black 5/8 inch (outside diameter) fittings that carry air from a Direct-It hoseline into a wall, ceiling or cabinet cavity. Injectidry supplies 17 in each Direct-It kit, so one pack replaces a full kit set.

Specifications

Injectidry part WP2
Outside diameter 5/8 inch (about 16 mm)
Drill bit 11/16 inch paddle bit (about 17.5 mm), per Injectidry's Direct-It manual
Pack size 17
Colour Black
System Injectidry Direct-It (Direct-It UAA2 and Direct-It IN UAA1)
Connects to 1.25 inch Direct-It hose cuffs (HC1) on 1.25 inch Direct-It hose (PL05)
CCW SKU IDWP2-17

HP or Direct-It?

Injectidry makes two families. HP is the negative-pressure system that pulls air through a cavity via manifolds and hose lines. Direct-It pushes air from an air mover into a confined space through an adapter. Some connectors are shared and many are not — check which system a part is listed for before ordering.

Larger holes, more air

At 5/8 inch these move considerably more air than the 3/16 inch HP wall injectors — which is what the Direct-It approach needs, because it is pushing air in rather than metering replacement air into a vacuum.

The trade-off is the make-good. A 5/8 inch hole is a patch and paint job, not a filler-and-touch-up. Agree that with the customer before you drill.

Where They Fit in a Direct-It Setup

Injectidry's Direct-It kits (Direct-It UAA2 for axial fans and air scrubbers and Direct-It IN UAA1 for standard air movers) run in this order:

  • Adapter on the air mover or air scrubber
  • 3 × 1.25 inch × 50 ft Direct-It hoses (PL05)
  • 17 × 1.25 inch hose cuffs (HC1)
  • 17 × 5/8 inch wall penetrators (this pack)
  • 10 end cap plugs (QCEP01) for outlets you are not using

Injectidry rates each Direct-It kit at 22 linear feet (about 6.7 m) of wall as packaged.

Fitting Advice

  1. Check for cables and pipes before drilling. Injectidry recommends an adjustable drill stop so the bit cannot go past the lining into services.
  2. Drill with an 11/16 inch paddle bit so the penetrator seats firmly.
  3. Where the finish allows, drill where the patch will be hidden, such as behind skirting boards that are coming off anyway or inside cabinets.
  4. Push the penetrator into its hose cuff, then into the hole, and check each one is seated before starting the air mover.

Frequently Asked Questions

Will these work with the Injectidry HP system?

No. HP uses 3/16 inch wall injectors on 3/8 inch tubing. The WP2 penetrators are for Direct-It only.

What size hole do they need?

Injectidry specifies an 11/16 inch paddle bit for the 5/8 inch penetrator.

Why 17 in a pack?

It matches the 17 hose cuffs supplied in a Direct-It kit, so one pack re-equips a full kit.

Do they suit both Direct-It adapters?

Yes. Injectidry supplies the same 17 × WP2 penetrators with both the Direct-It UAA2 and the Direct-It IN UAA1.

Related Products


Injectidry parts are system-specific — HP and Direct-It use different connections. Tell us which system you run and we will confirm the part before you order.