Replacement top case (Wagner part CST-62200-001) for the Wagner L622 hand-held moisture meter. It is the upper half of the meter housing, which surrounds and seals the electronics and the display.
Replace it when the original is cracked, broken or no longer sealing. A damaged case lets dust and moisture into the meter, and a mill or kiln environment is hard on both.
Important: Two Top Cases Are Listed
CCW lists two Wagner top cases:
- This part, CST-62200-001, for the L622.
- Wagner L612/L622 Hand-Held Moisture Meter Top Case, CST-61200-001, listed for the L612 and L622.
We are confirming with Wagner which part fits which production of the L622. Send us your meter's model and serial number before you order, and we will confirm the right case.
Case, Not Calibration
Replacing a cracked top case restores the protection around the electronics and the display. It does not affect calibration. A meter that has been dropped hard enough to crack its case is worth checking before it is trusted again. Use the Wagner Calibration Verification Block: Wagner's L622 manual gives a correct reading of 20.0 %MC on the block, with 18.0 to 22.0 %MC acceptable.
Compatibility
Wagner now lists the L622 as a legacy meter, so spare parts may become harder to source over time.
Specifications
| Brand | Wagner Meters (USA) |
|---|---|
| Wagner part number | CST-62200-001 |
| Part | Meter top case (upper housing) |
| Fits | Wagner L622 (confirm with serial number) |
| SKU | WECST-62200-001 |
Fitting Advice
- Remove the battery before opening the meter.
- Photograph the inside before moving anything, so the display, keypad and cables go back the same way.
- Transfer the electronics carefully; do not force ribbon cables or connectors.
- Check the seal around the display and case join before closing up.
- Run the air test and the verification block test before returning the meter to service.
If you are not comfortable working inside the meter, ask us about repair options before you start.
Frequently Asked Questions
Will a new case fix wrong readings?
No. The case protects the electronics. If readings are wrong, check calibration with the verification block and contact us.
Which top case do I need?
Send us the model and serial number. Two part numbers are listed and we will confirm which fits.
Does it include the keypad or display?
The part is listed as the top case only. Ask us if you also need other housing parts.
Related Products
- Wagner L612/L622 Top Case (CST-61200-001)
- Wagner Calibration Verification Block, L-Series
- Moisture Meter Parts
- Wagner Moisture Meters
Wagner part numbers are specific to the meter series. Tell us your model and we will confirm before you order.