Tramex Insulated RH Hood

Regular price $211.75 Regular price $192.50

Tramex insulated RH hood for surface humidity testing

An insulated hood that seals to the floor surface and allows relative humidity to equilibrate beneath it, for non-destructive testing of concrete and other floors and screeds.

Fitment

  • Tramex CMEX2
  • Tramex CMEX5
  • Tramex MRH3

Specifications

Type Insulated surface RH hood
Standard Surface RH testing to AS 1884-2012
Method Non-destructive — no drilling

Non-destructive, and that is the point

AS 1884-2012 is the Australian standard for resilient floor coverings, and the surface hood method it describes does not require drilling into the slab. On a finished floor, in a tenanted building, or where the slab is post-tensioned and drilling is not an option, that matters a great deal.

It is a different test from in-situ ASTM F2170, which measures humidity at depth inside the slab. Neither replaces the other. Check which one your flooring specification actually calls for — installing to the wrong test is the kind of mistake that only surfaces once the floor lifts.

For in-situ ASTM F2170 testing you need hole liners, probes and the accessory box instead.


Tell us which meter you run and we will confirm the right accessory before you order.