Coaxial cable assembly for hammer electrodes
The replacement lead between a hammer electrode and the meter, supplied with its RF connector and strain relief already fitted.
Fitment
Specifications
| Part number | 315CAB-0001 |
|---|---|
| Type | Coaxial cable assembly |
| Supplied with | RF connector and strain relief |
| Sold as | Each |
Important — the hammer electrodes take a different cable
This assembly fits the 26-ES and 26-ED only. Every other standard Delmhorst electrode uses the 315CAB-0025 cable assembly. The two are not interchangeable, so check which electrode you are repairing before ordering.
Why the cable fails first
On a slide hammer the cable takes a shock load on every drive and is repeatedly coiled and dragged. The usual failure is at the strain relief, and it shows up as readings that jump or drop out when the lead is moved. If a meter reads erratically only with the hammer electrode connected, suspect the cable before the meter.