Flexible Plain Core Duct 150mm x 6m

Regular price $31.35

SKU:MF1311400

Flexible plain-core duct, 150 mm diameter, 6 metre length. Plain duct. Black inner core - metallised outer surface.

It is general ventilation duct: for moving air from a fan, air mover adaptor or exhaust point to where it needs to go, where the duct has to hold its shape rather than lie flat.

Specifications

Diameter 150 mm
Length 6 m
Construction Plain core, black inner, metallised outer
Insulation None (plain core)
Operating temperature -20°C to +80°C (as listed by Reece for the same duct, code 1311400)
Operating pressure -190 Pa to +1,200 Pa (as listed by Reece)
Fire rating Not stated
CCW SKU MF1311400

Flexible duct, not layflat

Flexible plain-core duct holds its shape, which layflat does not. That matters where the duct has to run through a space rather than lie along it — into a ceiling void, across a subfloor, through a bulkhead — and anywhere it would otherwise collapse under its own weight or under negative pressure.

The trade-off is packing space. Layflat rolls up small; this does not.

For long runs from an air scrubber or dehumidifier, layflat is usually the better tool. CCW stocks Phoenix 250 mm layflat, Phoenix 355 mm layflat and 300 mm layflat.

Keep it short and keep the bends gentle

Every metre of duct and every tight bend costs airflow, and the loss is not proportional — a kinked duct can cut delivery to almost nothing while the machine sounds exactly the same. If a ducted setup is not drying, shorten the run before you add another machine.

Before You Use It

  • Check the spigot size. 150 mm duct needs a 150 mm outlet or adaptor. It will not seal on a larger outlet, and forcing it onto a smaller one restricts airflow.
  • Secure both ends. Use a duct clamp or duct tape so the duct cannot pull off under vibration or pressure.
  • Watch the temperature. The listed limit is +80°C. Do not connect it to a heater or heat-drying outlet that can exceed that.
  • Extend it fully. Flexible duct left bunched up in a concertina restricts airflow more than the same length pulled straight.
  • Check for tears. A split in the outer surface leaks air and, on negative-pressure setups, pulls in dust from where you do not want it.

Frequently Asked Questions

Is it insulated?

No. It is plain core. Where the duct runs through a cold space and condensation is a concern, use insulated duct.

Can I join two lengths?

Yes, with a 150 mm duct joiner and clamps or tape. Keep in mind that every extra metre costs airflow.

Is it fire rated?

No fire rating is stated. Do not use it where a building code or job specification calls for rated ductwork.

Which fans or air movers does it fit?

Anything with a 150 mm spigot or adaptor. Tell us the machine and we will confirm.