Replacement Toggle Cord Lock for the SpeedClean Mini Split Bib.
About SpeedClean Bibs
A bib wraps around an installed wall-mounted or cassette air conditioner and channels wash water and chemical into a bucket instead of down the wall. It is what makes it possible to wash an indoor coil properly in an occupied room rather than giving it a token wipe.
Small part, and it is usually the one at fault
When a bib will not stay tight, the toggle has almost always lost its spring or worn its grip before the cord has failed. It is the cheaper part and the quicker fix — replace the toggle first.
Specifications
| Brand | SpeedClean |
|---|---|
| Part | Spring toggle cord lock (VACP-57, from CCW SKU) |
| Suits | SpeedClean Mini-Split Bib (as listed by CCW) |
| Cord hole size, material | Not published by SpeedClean |
| Sold as | Each |
| CCW SKU | GWTVACP-57 |
Fitting It
- Press the toggle's button to release the cord and slide the old toggle off.
- Press the new toggle's button and thread the cord end or ends through the hole.
- Pull the cord tight on a unit and check the toggle holds under load before you wash.
Keep one or two spares in the bib bucket. At this price there is no reason to lose a job to a worn toggle.
Frequently Asked Questions
Which bib kits use it?
CCW lists it for the SpeedClean Mini-Split Bib. SpeedClean does not publish the toggle by kit, so send us your kit type and we will confirm.
The new toggle still slips.
Check the cord. A cord that has worn thin or glazed will slip through any toggle — replace the cord.