The check box is the part people skip
A non-invasive meter does not announce when it has been knocked out of true — it keeps producing plausible numbers. The only way to know is to put it on a known reference. Doing that at the start of a job, and recording it, is what turns a reading into evidence.
Which calibration check suits which meter
| Check device | For |
| CALBOXME5 check box | ME5 Moisture Encounter |
| CALBOXSMM5 check box | SMM5 Skipper 5 |
| MRH series check box | MRH series, including MRH3 |
| CALCRH check plate | CM series concrete meters – CME5, CMEX5 |
| Calibration check plugs, set of 3 | Pin-type meters |
| SAL75 75% salt check | Hygro-i2 relative humidity probes |
Impedance meters and RH probes are checked differently. An impedance meter is verified against a reference box or plate of known value; an RH probe is verified in a sealed salt chamber at a known humidity. One does not substitute for the other, and a meter that takes RH probes needs both.