Gum Blaster Wand

Regular price $657.71

SKU:AW08

The Hydro-Force Gum Blaster Wand (AW08) removes chewing gum from carpet using heat and pressure from a truckmount. Hot solution delivered through the wand softens and breaks down the gum so it can be removed, rather than scraped and picked out by hand. With enough heat, multiple gum deposits can be cleared within minutes — Hydro-Force describes dozens of pieces in a few minutes.

It is built around a 1,000 psi stainless steel valve and is designed to integrate with truckmount systems operating at 300–400 psi.

Why Heat Is the Key

Gum removal with this wand depends on temperature. Peak performance is achieved when water temperature at the wand reaches 75°C or higher; the elevated heat accelerates gum dissolution and extraction. Hydro-Force specifies a minimum of 170°F (about 77°C) at the wand and notes that the higher the heat, the quicker and better the gum is removed.

Measure the temperature at the wand, not at the machine. Long hose runs lose heat, and a wand that is below temperature will smear gum rather than lift it.

Key Features

  • 1,000 psi stainless steel valve
  • Stainless steel construction
  • Designed for truckmounts operating at 300–400 psi
  • Removes multiple gum deposits within minutes when heat is sufficient

Where It Is Used

  • High-volume gum removal on commercial carpet — cinemas, schools, retail and offices
  • Entrances, foyers and walkways where gum builds up between cleans

Is It Right for Your Machine?

The Gum Blaster is designed for truckmounts delivering 300–400 psi and 75°C or more at the wand. If your machine cannot reach that temperature at the wand — which is common with portables and long hose runs — the wand will not perform as intended. For small numbers of gum deposits, or on machines without the heat, a solvent and a hand tool are the practical alternative: see Actichem GumGone 500 ml spray and the Hydro-Force Xtreme G2 Gum Removal Tool.

Specifications

Brand Hydro-Force
SKU AW08
Valve 1,000 psi, stainless steel
Construction Stainless steel
Operating pressure Truckmount systems at 300–400 psi
Temperature at wand 75°C or higher (Hydro-Force: minimum 170°F / about 77°C)

Operating Advice

  • Test on an inconspicuous area first, particularly on wool and solution-dyed products where high heat can affect the fibre or dyes.
  • Let the machine come fully up to temperature before starting, and check the temperature at the wand.
  • Work each deposit until it is gone, then rinse and extract the area as normal to remove softened residue.
  • Stainless construction resists corrosion, but flush with clean water at the end of the day as you would any wand.

Frequently Asked Questions

What temperature do I need?

At least 75°C at the wand. Hydro-Force specifies a minimum of 170°F (about 77°C), and hotter is faster.

Can I use it with a portable?

It is designed for truckmounts at 300–400 psi. A portable that cannot deliver 75°C or more at the wand will not give the intended result.

Why does the valve rate at 1,000 psi when I only run 300–400 psi?

The 1,000 psi rating is the valve's capacity, not the working pressure. Running well within the rating is what gives a valve a long service life.

Do I still need a gum solvent?

With enough heat the wand does the work on its own. A solvent such as Actichem GumGone remains useful for odd deposits between wand jobs, or where the truckmount is not on site.

Related Products


Tell us your truckmount and hose length and we will confirm the Gum Blaster suits your setup before you order.