The Adaptidry, another example of the versatility of Injectidry's specialised drying equipment, achieves high efficiency by dispersing intense drying power simultaneously to multiple areas around the room.
The ADAPTIDRY is specifically designed to work with several pieces of drying equipment. The MAX Force and Phoenix Guardian HEPA filter* make a perfect companion to the ADAPTIDRY.
This ADAPTOR fits in well with today’s trend toward less destructive and non-invasive drying. Increasingly, Certified Industrial Hygienist are asking for more control and faster drying. The ADP-5 fits 12, 14 & 16-inch rings: Axial fans, MAX Force, Air Wolf, Abatement Technologies 1800 & 2400 Air Scrubbers.
- Creates more pressure, or vacuum suction within walls and without drilling holes, making it more effective than other vent systems. Also great for drying out sleepered floors (sport courts and gymnasiums).
- Can be used in a push-pull setup.
- When used with a HEPA Scrubbers it becomes a true HEPA filtration system.
- The ADP-5 fits 12, 14 & 16-inch rings: Axial fans, MAX Force, Air Wolf, Abatement Technologies 1800 & 2400 Air Scrubbers
How It Works
The Adaptidry dome sits on the duct ring of an axial fan, ventilator or air scrubber and splits its airflow across five ports, which feed 4 inch Mylar ducting and wall vents placed against the wall or floor being dried, so a whole section of wall cavity or sleepered floor is pressurised (push) or put under suction (pull) at once. Injectidry says that because such a large area is pressurised, it is not always necessary to drill holes in cabinets, walls and timber floors.
What's in the Box
- 1 x Adaptidry 5 Port Dome ADP5AHO
- 5 x 2 Foot Wall Vents WV2
- 1 x 1 Foot Wall Vents WV1
- 2 x Y -(4”) Y4
- 16 x Turn-Key Clamps DC-TK4
- 2 x Ducting (4” x 50’) M4
- 1 x Carry Bag CB1
- 1 x ADPRING*
- 1 x Operations Manual
*NOTE: The newer model Phoenix Thermastor Guardian no longer has a sheet metal collar for the intake. To adapt the ADP-5 to the newer style Guardian or the older style without the collar, place the separate ring provided on the face of the Guardian port (on top of the unit) and then place the ADP-5 onto it. The ring is also sold separately as the Direct-It duct ring for ADP-5 or ADP-9 to Guardian.
Injectidry lists its M4 Mylar ducting as a case of 4 × 25 ft, rated to 160°F (about 71°C). CCW's list above gives 2 × 50 ft — the same 100 ft (about 30 m) either way.
Important: Drying Accessory, Not Containment
Run through a HEPA air scrubber, the air leaving the system has passed the scrubber's HEPA filter. That does not make the Adaptidry a containment or negative-air system for mould or asbestos work. Where a scope calls for containment, set it up separately with a dedicated air scrubber and follow the job specification.
Specifications
| Injectidry part | ADP-5 (dome ADP5AHO) |
|---|---|
| Ports | 5 |
| Duct rings | 12, 14 and 16 inch |
| Suits | Axial fans, MAX Force, Air Wolf, Abatement Technologies 1800 and 2400 air scrubbers; Phoenix Guardian with the ring supplied |
| Modes | Positive (push) or negative (pull) |
| Ducting | 4 inch Mylar, 100 ft total (rated 160°F / about 71°C) |
| Drying capacity | Up to 18 linear feet (about 5.5 m) per Injectidry's price list; about 20 linear feet per Injectidry's ADP-5 page |
| CCW SKU | IDADP-5 |
The two Injectidry capacity figures differ. Plan on the lower one (18 ft) until the job proves otherwise.
Setting Up
- Check the ring size on the machine. On a newer Guardian, or an older one without the collar, fit the ring first.
- Seat the dome on the ring and connect the ducting to the ports with the turn-key clamps.
- Use the Y pieces to split runs where needed, and place the wall vents against the wall or floor being dried.
- Start the machine and check every vent is getting air (push) or pulling (pull) before you leave the site.
- Follow the Injectidry operations manual supplied for mounting and safety.
Frequently Asked Questions
ADP-5 or ADP-9?
The ADP-5 suits a room or a single long wall. For larger areas, the Adaptidry 9 Port spreads the same machine across more vents.
Will it fit my Phoenix Guardian?
Yes, with the ADPRING. The newer Guardian has no sheet metal collar on the intake, so the ring goes on the Guardian port and the ADP-5 sits on the ring.
Do I have to drill the wall?
Not always. Injectidry says the large pressurised area often avoids drilling. If you need to drive air into specific cavities, a drilled system such as Injectidry HP or Direct-It is the tool for that.
Can I use it with a normal carpet air mover?
It is designed for machines with 12, 14 or 16 inch duct rings — axial fans, ventilators and air scrubbers. A standard centrifugal carpet air mover has no duct ring to seat it on.
Can it run on a Dry Air Max Force?
Injectidry and CCW both list the MAX Force as a companion machine. See the Dry Air Max Force Ventilator.
Is the Mylar ducting heat rated?
Injectidry rates its M4 Mylar ducting to 160°F (about 71°C).
Related Products
- Injectidry Adaptidry 9 Port Injection Drying System
- Injectidry Direct-It Duct Ring for ADP-5 or ADP-9 to Guardian
- Injectidry Specialty Adapter 5-Port x 2 ft Wall Vents
- Injectidry Injection Drying Systems
Not sure which ring your machine has, or whether the ADP-5 or ADP-9 suits the job? Send us the machine make and model and we will confirm before you order.