Pressure Switch 220PSI for Aquatec DDP5800

Regular price $173.25 Sale price $149.00

SKU:AQT-PS-220

Replacement 220 psi pressure switch for the Aquatec 230 V 220 PSI Demand Pump (CCW code AQT-220), from the Aquatec DDP5800 series. The switch is what turns a demand pump on when the trigger opens and off when pressure is reached, and it can be replaced on its own without replacing the pump.

Specifications

Setting 220 psi
Fits Aquatec 230 V 220 PSI Demand Pump, CCW code AQT-220
Pump series Aquatec DDP5800
CCW SKU AQT-PS-220 (also listed by CCW under MPC323D)

Important — This Switch Is Pressure-Specific

This switch suits the 220 psi AQT-220 pump only. It is not for the 120 psi Aquatec pump (MPC306) or the 12 V pump in the SpeedClean CoilJet CJ-125. Fitting a 220 psi switch to a pump and machine built for lower pressure will over-pressure the solution line, jets and fittings.

An earlier version of this page listed the 12 V CoilJet pump as a fit. That was wrong and has been removed.

The Symptom

A failing pressure switch shows up as a pump that cycles rapidly with no demand, or one that will not shut off when pressure is reached. Both are hard on the pump.

Check for a leak first — a genuine leak produces the same rapid cycling and is a cheaper fix.

Fitting Advice

  • Isolate the machine from the mains before you start. Work on the mains side of a 230 V appliance is licensed work in Australia — order the part if a qualified person is doing the job; otherwise send the machine in.
  • Aquatec advise that the pressure switch set screw should not be adjusted more than one turn without consulting the factory.
  • Limit rapid on/off cycling to no more than 6 times per minute (Aquatec DDP guidance). A pump that cycles faster than that has a leak or a failing switch.

Operational and installation guidelines, Aquatec DDP series (PDF)

Frequently Asked Questions

Will this fit my CoilJet?

No. This switch is for the 230 V AQT-220 pump only.

Can I use it to raise the pressure of a 120 psi pump?

No. Every component downstream — solution line, jets and fittings — is rated for the pressure the machine was built with. Match the switch to the pump.

Do I need a new pump or just the switch?

If the pump runs but cycles without demand or will not shut off, rule out a leak and then the switch before replacing the pump.


Tell us the machine or tool and we will confirm the part before you order.