Overview
Run capacitor, 6 µF, 370 VAC, for the Phoenix AirMax fan motor. Phoenix part number 4035235-03. It replaces 4037221-06.
What it fits
- Phoenix AirMax — named in the 50 Hz service parts list as Run Capacitor, 6 mfd, 370 VAC
Important — the 4035235 family has several values
Phoenix use the same base part number with different suffixes for different capacitance values, and they are not interchangeable:
- 4035235-03 — 6 µF, 370 VAC — AirMax fan motor (this part)
- 4035235-01 — 4 µF, 370 V — 250MAX impeller
- 4035235-09 — R150 impeller
Read the value printed on the capacitor you are removing. The suffix is the specification, and ordering by base number alone will get you the wrong part.
Important — the US 115 V AirMAX uses a different capacitor
Phoenix's current AirMAX owner's manual (TS-890) covers the US 110–120 V, 60 Hz machine, and its service parts list gives 4035235-08, 20 mfd, 370 VAC as the run capacitor. That is not this part. This 6 µF capacitor is the value CCW's 50 Hz AirMax service parts list gives for the 230 V machine sold in Australia.
US parts sites also list 4035235-03 against other Therma-Stor machines. Do not order from a US parts list — match the value on the capacitor in your machine.
Specifications
| Phoenix part number | 4035235-03 (replaces 4037221-06 — CCW record) |
| Capacitance | 6 µF (mfd) |
| Voltage rating | 370 VAC |
| Type | Run capacitor, fan motor |
| Fits | Phoenix AirMax, 230 V / 50 Hz |
| Dimensions and terminal layout | Not published — compare with the part you are removing |
Symptoms of a failed fan capacitor
- Motor hums but the impeller does not turn
- Impeller starts only if you help it by hand — a classic dead-capacitor symptom, and a good reason to stop and unplug the machine rather than keep doing it
- Motor runs hot, or noticeably down on airflow
- Machine trips a breaker on start-up
A bulged, split or weeping capacitor is finished on sight. One that looks fine can still be well below value — test it rather than judging by appearance.
Safety
Capacitors hold a charge after the machine is unplugged. Discharge it safely before handling.
Photograph the terminal connections before you disconnect anything.
Replacing a capacitor is electrical work. Have it done by a licensed electrician or qualified technician, and have the machine electrically tested before it goes back into service.
Related parts
Other AirMax service parts from the same list:
- 4036575 — impeller assembly
- 4035665 — rubber feet
- 4035825 — rocker switch
- 4037469 — inlet grill
- 4024936 — lay-flat duct, 14" × 250' (optional)
Only the duct is currently a stocked CCW line — ask us about the others.
Frequently asked questions
Does it replace 4037221-06?
Yes — that is stated in CCW's record for this part.
Can I fit a 4 µF or a 3 µF instead?
No. Match the value.
Can I fit a higher voltage rating?
A higher voltage rating is generally acceptable where a capacitor physically fits; a lower one is not. Ask us if you are unsure — do not guess on a motor circuit.
Which machines take it?
The Phoenix AirMax. Other Phoenix machines use different values from the same family.
Read the µF value off your existing capacitor and send it to us with the machine model — we will confirm the right one before you order.