Aquatec 12v 170 PSI Demand Pump

Regular price $693.04

SKU:GWTCJ2-06-S

The replacement motor and pump assembly for the SpeedClean CoilJet CJ-125 battery coil cleaner. It is an Aquatec DDP5800 series 12-volt demand flow diaphragm pump, designed as a direct replacement, and keeps the CJ-125 delivering reliable, high-pressure water whenever the trigger is pulled.

SpeedClean list this assembly as part number CJ2-06-S, Motor/Pump Assembly.

Specifications

Fits SpeedClean CoilJet CJ-125
SpeedClean part number CJ2-06-S (Motor/Pump Assembly)
Pump series Aquatec DDP5800
Type Diaphragm demand pump with demand flow switch — starts when the trigger opens, stops when it closes
Voltage 12 V DC
Pressure 170 psi (CCW description). The SpeedClean CJ-125 manual rates the complete machine at 125 psi (8.5 bar).
Flow rate 5.3 L/min (CCW description). The SpeedClean CJ-125 manual gives 0.7 gpm (2.6 L/min) for the machine.
Current draw 13.5 A (CCW description). The CJ-125 manual lists 15 A input for the machine.
CCW SKU GWTCJ2-06-S

Where CCW's figures and the SpeedClean manual differ, both are shown. The manual rates the whole machine at the nozzle; the CCW figures describe the pump. If the exact rating matters for your application, contact CCW before ordering.

Is It the Pump?

Rule these out before replacing the assembly. The CJ-125 manual lists them as the common causes of pump complaints:

  • Will not prime — a clogged check valve. Clean or replace the check valve first.
  • Keeps running after the trigger is released — a leak on the high-pressure side (spray gun or pump fittings) or air in the system. Check for leaks and re-prime.
  • Inconsistent pressure — air in the pump or poor priming. Remove the nozzle and prime the pump.

A pump that cycles on and off without the trigger being used is almost always a leak rather than a pump fault. It is also hard on the battery.

Getting the Best Life From It

  • Never run it dry. Running a pump dry drains the battery and may damage the pump. Keep liquid in the tank.
  • Do not leave the unit sitting in automatic shut-off with the power switch on for more than 10 minutes.
  • Charge the battery after every use. A sealed lead-acid battery left discharged may be permanently damaged. Use only the supplied smart charger.
  • Flush with clean water at the end of the day so chemical residue does not dry in the valves.

Frequently Asked Questions

Is this a genuine CoilJet part?

CCW supplies it against SpeedClean part number CJ2-06-S, the CJ-125 motor/pump assembly, built on the Aquatec DDP5800 series pump.

Will it fit my CoilJet?

It is the replacement assembly for the CJ-125. If you have another CoilJet model, send us the model before ordering.

My pump runs but will not build pressure. Is the pump finished?

Not necessarily. Check the check valve and prime the pump first. Air in the pump and a blocked check valve both cause poor pressure and are cheaper to fix.

What else should I check while it is apart?

The one-way check valve. The CJ-125 manual names a clogged check valve as the cause of a pump that will not prime, and it is a much cheaper part than the pump.

Related Parts


Not sure the pump is the fault? Tell us what the CoilJet is doing and we will help you find the part before you order.