CleanTrust™ Touch™ YZ3500 Luminometer

Regular price $5,291.49

SKU:CTYZ3500

Stop guessing. Start measuring.

If you're serious about restoration, hygiene and compliance work, you need more than visual inspection.

The CleanTrust™ Touch™ YZ3500 Luminometer gives you fast, measurable evidence of cleanliness, detecting ATP contamination on surfaces and in water with a 10-second reading.

Paired with CleanTrust ATP swabs, this unit becomes the central tool for verifying cleaning effectiveness and contamination risk on site. CleanTrust is a brand of Anaeron Pty Ltd, Frenchs Forest NSW.

Why This Matters on the Job

  • Prove your work to clients and insurers. Replace "it looks clean" with measurable data.
  • Make better decisions on site. Identify contamination straight away and act immediately.
  • Reduce call-backs and disputes. Back up your results with recorded evidence.
  • Win higher-value commercial and insurance work. Professional testing = higher credibility.

Key Benefits

  • Instant ATP detection (results in seconds). No waiting days for a lab to report ATP — you get an answer on site. ATP is a hygiene indicator, not a mould or bacteria count; see the FAQs.
  • High-sensitivity measurement. A photodiode detector with single-photon counting detects even low contamination levels (1 × 10⁻¹⁶ mol ATP, Anaeron).
  • Simple touchscreen operation. The 5.5 in (14 cm) Android-based interface makes it easy for any technician to use.
  • Data logging and reporting capability. Store and analyse results for QA, compliance and reporting.
  • Wireless connectivity (WiFi / Bluetooth / USB-C). Transfer data easily across devices and systems.
  • Works with surface and water ATP swabs. Covers both environmental and water contamination testing with CleanTrust ATP Surface Swabs and CleanTrust ATP Water Total Swabs.

Ideal For

  • Water damage restorers verifying post-clean contamination levels
  • Mould remediation projects requiring clearance validation
  • Contractors working on insurance or compliance-driven jobs
  • Commercial cleaners implementing QA programs
  • HVAC cleaning where biofilm or contamination is suspected

How It Works

  1. Swab the surface or water sample.
  2. Insert the swab into the luminometer.
  3. Run the test (≈10 seconds).
  4. Get an RLU reading (contamination level).

Higher reading = higher contamination: clean again before sign-off.

In more detail, from Anaeron's YZ3500 user manual:

  1. Turn the meter on. If it has come from a hot van or a cold site, let it sit for 10–20 minutes so it is close to room temperature.
  2. Stand it on its rear support on a flat surface, or hold it with less than 45° of tilt. A built-in gyroscope warns you if it tilts too far during a test.
  3. Swab a 10 × 10 cm area, horizontally and vertically, return the swab to its tube, break the valve, squeeze the bulb to release the liquid and shake.
  4. Open the chamber cover, insert the swab vertically and close the cover. The test starts automatically.
  5. Read the result, then remove the swab straight away. Re-testing an old swab gives unreliable readings.

Pass, Caution and Fail Thresholds

Each result is judged against a minimum and maximum RLU value you set. Below the minimum is a pass, between the two is caution, and above the maximum is a fail. Anaeron quotes a default threshold of 20–60 RLU for the meter. Anaeron's ATP surface swab instructions suggest different default limits (under 10 pass, 10–30 warning, over 30 fail), so decide your own limits and set them in the meter before you rely on the colour-coded result.

Thresholds can be saved per test location, so a kitchen bench and a subfloor can carry different limits.

Technical Specifications

Brand / model CleanTrust™ Touch™ YZ3500 (Anaeron Pty Ltd)
CCW SKU CTYZ3500
Test time ~10 seconds per reading
Detection range 0–32,000 RLU
Sensitivity Down to 1 × 10⁻¹⁶ mol ATP
Detector Photodiode, single-photon counting
Sensors Gyroscope (tilt warning), chamber cover switch, swab detection
Swab length 17 cm CleanTrust swabs
Display 5.5 in (14 cm) touchscreen (Android OS)
Data storage Up to 10 million records (50 GB, expandable by SD card)
Connectivity WiFi, Bluetooth, USB-C
Battery Rechargeable lithium, 3.7 V 3500 mAh, removable (IEC 62133-2)
Tests per charge Up to ~3000 tests per charge (CCW and Anaeron website); the Anaeron user manual states 2500 samples of continuous detection
Standby 20 days (user manual); 15 days (Anaeron flyer)
Dimensions 190 × 82 × 34 mm
Weight 400 g
Certification (manufacturer) CE, RoHS
Warranty 2 years

Recording and Reporting

  • Locations: name each test point and give it its own thresholds.
  • Plans: group locations into a test plan with reminders, so every point on a job gets tested.
  • Inspectors: log which technician ran each test, with optional passwords.
  • History: filter results by pass, caution and fail, by inspector, location, plan and date, and view trends by day.
  • Export: results export as a spreadsheet file over USB-C, or sync to Anaeron's PC analysis software (WiFi or USB) or its cloud platform.

Deleting records can be password-protected. The manual's initial management password is 123456, so set your own before the meter goes on a job.

Calibration

The meter has an automatic calibration function. Anaeron also provides a calibration check routine (internal LED, negative and positive tests) that needs its calibration quality control tube. That tube is not currently listed by CCW; contact us if your QA program requires documented calibration checks.

Care and Battery

  • Keep the chamber cover closed when not testing, and keep the chamber out of strong light.
  • Never let liquid into the chamber. If the meter gets wet, do not turn it on; remove the battery.
  • Clean the case with a damp cloth or neutral detergent. Keep solvents, grease and corrosive products off the meter.
  • Charge only with the supplied adapter and unplug when full. Charge at least monthly in storage, and run a full charge-discharge cycle every three months.
  • Anaeron's manual says to remove the lithium battery when transporting the instrument.

Why Professionals Use a Luminometer

Without ATP testing:

  • You're relying on visual inspection
  • Contamination can go undetected
  • Results are hard to defend

With a luminometer:

  • You get objective, measurable evidence
  • Your process becomes repeatable and professional
  • You can justify your work and pricing with data

This is what separates basic cleaning from professional restoration and hygiene verification.

Part of a Complete Testing System

The YZ3500 is the core of a contamination verification system:

Together, this creates a full QA and reporting workflow.

Pro Tip

Set internal pass/fail RLU thresholds for your business. This standardises results across technicians and makes your reporting far more defensible.

Common Mistakes This Helps Avoid

  • Relying on visual cleanliness alone
  • Missing contamination in critical areas
  • Inconsistent results between technicians
  • Failing hygiene audits or insurance requirements
  • Not having evidence when a job is questioned

Frequently Asked Questions

Which swabs does it read?

Anaeron lists CleanTrust ATP Surface Swabs and CleanTrust TOTAL ATP Water Swabs, and the manual says to use only matching swabs. Protein swabs are read by eye.

Does a low RLU mean the surface is free of mould or bacteria?

No. ATP measures organic residue from living and once-living material. It is a fast hygiene indicator, not a count or identification of mould or bacteria, and it does not replace laboratory sampling where a clearance specification calls for it.

How many tests will I get from a charge?

Anaeron's website and CCW quote about 3000; the user manual says 2500. Plan on the lower figure for a long day and charge overnight.

What RLU limit should I use?

There is no single restoration standard. The meter ships with Anaeron's default (20–60 RLU) and the swab instructions suggest tighter limits. Pick limits that suit your work, set them per location and apply them consistently.

How do I get results into my report?

Export from History to a spreadsheet file over USB-C, or sync to Anaeron's PC analysis software or cloud platform.

What is the warranty?

2 years. Your rights under Australian Consumer Law apply in addition; see below.

Turn Your Cleaning into Measurable Results

Add the CleanTrust YZ3500 to your workflow and start delivering data-backed cleaning, not guesswork.

Documents

CleanTrust™ Touch™ YZ3500 Luminometer Flyer

CleanTrust™ Touch™ YZ3500 Luminometer Manual

Video

Related Products

Your rights under Australian law

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

These rights apply in addition to the manufacturer’s warranty set out above and are not limited by it. Contact Carpet Cleaners Warehouse first and we will handle the claim from this end.


Setting up ATP testing for the first time, or not sure what thresholds to use? Contact Carpet Cleaners Warehouse before ordering and we will help you choose the meter and swabs for your work.