Protimeter short QuickStick humidity sensor
An interchangeable relative humidity and temperature probe for general humidity measurement.
Specifications
| Part number | POL8751 |
|---|---|
| Range | 0–99% RH |
| Response | Fast responding |
| Supplied as | Standard with MMS3 and MMS2 kits |
Compatible meters
- Protimeter MMS3
- Protimeter MMS2
- Protimeter HygroMaster 2
- Protimeter HygroMaster L
QuickStick or Hygrostick?
The QuickStick is the fast-responding general-purpose sensor — it is what you want for walking a building and taking ambient readings. The Hygrostick (POL4750) is specified by Protimeter for high humidity applications, and the mini Hygrosticks are the ones designed to be left in a concrete slab.
They are interchangeable on the same meters, so most surveyors carry a QuickStick for ambient work and Hygrosticks for the jobs that need them.
Sensors drift, and drift is invisible
A humidity sensor that has been through a mould job, a fire or a summer in a vehicle will read differently from a new one, and nothing on the display says so. Verify it against the 75% RH salt check before any job whose numbers go into a report.
Related parts
- Hygrostick (POL4750) — the high-humidity alternative
- Hygrostick 5 pack (BLD4750C)
Meters this fits
- Protimeter MMS3 — and the MMS2 it replaced
- Protimeter HygroMaster 2
- Protimeter HygroMaster L
It does not fit the SurveyMaster, TimberMaster, Mini range, Aquant or ReachMaster Pro. Those measure moisture in materials rather than humidity in air, and take no humidity sensor.
Tell us which Protimeter you run and we will confirm the right part before you order.