{"product_id":"hygiena-systemsure-plus-atp-meter-only","title":"Hygiena SystemSURE Plus (ATP Meter Only)","description":"\u003cp\u003eHygiena's™ SystemSURE Plus is the world's best-selling ATP Sanitation Monitoring System (Hygiena's description). With improved functionality, new software, and increased memory, the SystemSURE Plus meets the demands of the cleaning and restoration companies around the world.\u003c\/p\u003e\n\u003cp\u003eThis listing is the meter only (Hygiena code SS3). If you are starting from nothing, the \u003ca href=\"\/products\/hygiena-systemsure-plus-atp-meter-starter-kit\"\u003eSystemSURE Plus Starter Kit\u003c\/a\u003e adds 100 UltraSnap swabs, a carrying case and a meter stand.\u003c\/p\u003e\n\u003ch2\u003eWhat Is ATP Testing?\u003c\/h2\u003e\n\u003cp\u003eThe ATP test is a process of rapidly measuring actively growing microorganisms through the detection of adenosine triphosphate, or ATP.\u003c\/p\u003e\n\u003cp\u003eATP is a molecule found in and around living cells, and as such it gives a direct measure of biological concentration and health. ATP is quantified by measuring the light produced through its reaction with the naturally occurring firefly enzyme luciferase using a luminometer. The amount of light produced is directly proportional to the amount of ATP present in the sample.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat a reading is and is not:\u003c\/strong\u003e ATP is present in organic residue generally — food soil, body fluids, biofilm and the cells within them — not only in living microorganisms. A reading in relative light units (RLU) tells you how much organic residue is on the surface. It does not identify organisms and it is not a microbial count. Use it to verify that cleaning removed the soil; use laboratory microbiological sampling where a job needs organisms identified or counted.\u003c\/p\u003e\n\u003ch2\u003eWhy Use ATP Testing?\u003c\/h2\u003e\n\u003cp\u003eWith ATP testing, a restoration contractor can test the initial condition of surfaces and standing water to determine the level of contamination and thus categorize the loss more accurately as 1, 2 or 3.\u003c\/p\u003e\n\u003cp\u003eThe testing can also be used during the cleaning and drying processes to determine progress. And finally, at the completion of the job, testing can verify clean and sanitary materials and surfaces.\u003c\/p\u003e\n\u003cp\u003eKeep the categorisation point in proportion: an ATP result is supporting evidence, not the classification itself. Water category is decided from the source of the water, how long it has been there and what it has contacted, as your restoration standard sets out. A high reading supports treating the loss as contaminated; a low reading on its own does not make a loss Category 1.\u003c\/p\u003e\n\u003ch2\u003eSystemSURE Plus Benefits\u003c\/h2\u003e\n\u003cp\u003eAs listed by Hygiena:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMost cost-effective ATP hygiene monitoring system available\u003c\/li\u003e\n\u003cli\u003eProvides real-time feedback and facilitates long-term data analysis\u003c\/li\u003e\n\u003cli\u003eOptimizes and verifies that cleaning procedures are working\u003c\/li\u003e\n\u003cli\u003eAssists in developing and improving process and risk assessment programs (ie. HACCP \u0026amp; GMPs)\u003c\/li\u003e\n\u003cli\u003eNo scheduled yearly maintenance is necessary\u003c\/li\u003e\n\u003cli\u003eAvailable Calibration Control Kit for in-house confirmation of calibration\u003c\/li\u003e\n\u003cli\u003eComplimentary SureTrend Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSystemSURE Plus Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSensitive - can detect down to 1 femtomole (1 x 10\u003csup\u003e-15\u003c\/sup\u003e moles) of ATP\u003c\/li\u003e\n\u003cli\u003eAdvanced photodiode sensor offers low variation and stays in calibration\u003c\/li\u003e\n\u003cli\u003eCalibration self-check at start up with optional full diagnostic check mode\u003c\/li\u003e\n\u003cli\u003eThe symbol keypad is easy for any user to understand and navigate\u003c\/li\u003e\n\u003cli\u003ePowered by 2 x AA batteries for several months of uninterrupted use\u003c\/li\u003e\n\u003cli\u003eMemory capacity:\n\u003cul\u003e\n\u003cli\u003e100 programmable test plans\u003c\/li\u003e\n\u003cli\u003e200 programmable user IDs\u003c\/li\u003e\n\u003cli\u003e251 programmable locations per test plan\u003c\/li\u003e\n\u003cli\u003e5,000 programmable test locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmall, lightweight, handheld instrument (0.57 lbs., 7.6 x 17.8 x 3 cm)\u003c\/li\u003e\n\u003cli\u003eQuick-test mode enables ad-hoc testing\u003c\/li\u003e\n\u003cli\u003eLarge viewable screen with back-light and optional bold text\u003c\/li\u003e\n\u003cli\u003eRemovable read chamber for easy cleaning\u003c\/li\u003e\n\u003cli\u003eConnects to SureTrend software via USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAt a Glance\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand \/ model\u003c\/th\u003e\n\u003ctd\u003eHygiena SystemSURE Plus (SS3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd\u003eHGSS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSensor\u003c\/th\u003e\n\u003ctd\u003ePhotodiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDetection limit\u003c\/th\u003e\n\u003ctd\u003e1 femtomole (1 × 10\u003csup\u003e-15\u003c\/sup\u003e mol) ATP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResult time\u003c\/th\u003e\n\u003ctd\u003eAbout 15 seconds (Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower\u003c\/th\u003e\n\u003ctd\u003e2 × AA batteries — Hygiena quotes up to 8–12 months of use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSize\u003c\/th\u003e\n\u003ctd\u003e7.6 × 17.8 × 3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.57 lb (about 260 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eResults memory\u003c\/th\u003e\n\u003ctd\u003e2,000 test results (Hygiena)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eData connection\u003c\/th\u003e\n\u003ctd\u003eUSB to SureTrend software (cable sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCalibration check\u003c\/th\u003e\n\u003ctd\u003eStart-up self-check; CalCheck for in-house verification (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eNot published by Hygiena — ask CCW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhich Tests It Reads\u003c\/h2\u003e\n\u003cp\u003eHygiena lists the SystemSURE Plus as compatible with its UltraSnap surface ATP test and AquaSnap water ATP test, and with its other luminometer-read test devices. The Hygiena tests CCW stocks:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hygiena-ultrasnap-atp-surface-test-swab-100-pk\"\u003eHygiena UltraSnap ATP Surface Test Swab (100pk)\u003c\/a\u003e — the standard surface test; also in a \u003ca href=\"\/products\/hygiena-ultrasnap-atp-surface-test-swab-80-x-25-swabs2000pk\"\u003e2,000 pack\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hygiena-supersnap-for-systemsure-plus-100pk\"\u003eHygiena SuperSnap (100pk)\u003c\/a\u003e — higher-sensitivity surface test\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hygiena-aquasnap-total-for-rinse-waters-100pk\"\u003eHygiena AquaSnap Total (100pk)\u003c\/a\u003e — water and rinse water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003ca href=\"\/products\/hygiena-pro-clean-protein-colour-hygiene-test-100pk\"\u003ePRO-Clean\u003c\/a\u003e and \u003ca href=\"\/products\/hygiena-spotcheck-plus-glucose-lactose-colour-hygiene-test-100pk\"\u003eSpotCheck Plus\u003c\/a\u003e tests are colour-change tests read by eye — they do not need the meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThird-party swabs:\u003c\/strong\u003e Anaeron lists its CleanTrust \u003ca href=\"\/products\/cleantrust-atp-surface-swab-box-of-100\"\u003eATP Surface Swab\u003c\/a\u003e as compatible with the SystemSURE Plus. Hygiena lists only its own tests. If you mix brands, set a separate baseline and limits for each swab type — RLU figures from different swab chemistries are not interchangeable.\u003c\/p\u003e\n\u003ch2\u003eUsing It Well\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLet the tests warm up.\u003c\/strong\u003e Hygiena's UltraSnap instructions call for the device to reach 21–25 °C before testing. A swab straight from the fridge reads low.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwab the same way every time.\u003c\/strong\u003e A 10 × 10 cm area in a criss-cross pattern is Hygiena's standard for flat surfaces. Results are only comparable when the sampling is.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead promptly.\u003c\/strong\u003e Insert the activated swab within 30 seconds (UltraSnap instructions). The SystemSURE Plus gives the result in about 15 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet your own limits.\u003c\/strong\u003e The meter supports programmable pass, caution and fail limits. Build them from readings on surfaces you know are properly cleaned, not from a number copied from someone else's procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSanitiser still on the surface can suppress the reading.\u003c\/strong\u003e Sample after cleaning and before sanitising, or allow for it in your procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCalibration and Data\u003c\/h2\u003e\n\u003cp\u003eThe meter runs a sensor self-check at start-up. For in-house confirmation between checks, Hygiena's reusable \u003ca href=\"\/products\/hygiena-cal-check-reusable\"\u003eCalCheck\u003c\/a\u003e replaces the older PCD4000 Calibration Control Kit. A CalCheck verifies the meter; it does not adjust it — a failed check means contact CCW.\u003c\/p\u003e\n\u003cp\u003eResults transfer to Hygiena's SureTrend software over USB using the \u003ca href=\"\/products\/hygiena-systemsure-atp-usb-cable\"\u003eSystemSURE Plus USB cable\u003c\/a\u003e. Hygiena now also offers SureTrend as a cloud platform; confirm with CCW which version and licence applies before you build a reporting system around it.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat comes with the meter-only listing?\u003c\/h3\u003e\n\u003cp\u003eThe luminometer. Hygiena supplies the SystemSURE Plus with a protective carrying case and shoulder strap; confirm with CCW what is in the box on current stock. Swabs, the USB cable and the CalCheck are sold separately.\u003c\/p\u003e\n\u003ch3\u003eDoes it need annual calibration?\u003c\/h3\u003e\n\u003cp\u003eHygiena says no scheduled yearly maintenance is needed. Use the CalCheck to confirm the meter is reading correctly between checks.\u003c\/p\u003e\n\u003ch3\u003eCan it tell me whether a surface has bacteria or mould on it?\u003c\/h3\u003e\n\u003cp\u003eNo. It measures ATP, which is present in organic residue generally. It shows how clean a surface is, not which organisms are on it.\u003c\/p\u003e\n\u003ch3\u003eSystemSURE Plus or EnSURE Touch?\u003c\/h3\u003e\n\u003cp\u003eBoth read Hygiena's ATP tests. The \u003ca href=\"\/products\/hygiena-ensure-touch-atp-meter\"\u003eEnSURE Touch\u003c\/a\u003e has a touch screen, Wi-Fi data transfer and a 10-second read. The SystemSURE Plus is the simpler keypad meter with USB download.\u003c\/p\u003e\n\u003ch3\u003eCan I use CleanTrust swabs in it?\u003c\/h3\u003e\n\u003cp\u003eAnaeron says yes; Hygiena lists only its own tests. See \"Which Tests It Reads\" above, and keep separate limits for each swab brand. CleanTrust also make their own \u003ca href=\"\/products\/cleantrust-touch-yz3500-luminometer\"\u003eTouch YZ3500 luminometer\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/tsjLPP6y1Ok\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/hygiena-systemsure-plus-atp-meter-starter-kit\"\u003eHygiena SystemSURE Plus Starter Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/hygiena-ultrasnap-atp-surface-test-swab-100-pk\"\u003eHygiena UltraSnap ATP Surface Test Swab (100pk)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/hygiena-cal-check-reusable\"\u003eHygiena CalCheck\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/hygiena-systemsure-atp-usb-cable\"\u003eHygiena SystemSURE Plus USB Cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/hygiena\"\u003eAll Hygiena products\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003eSetting up ATP testing for restoration sign-off? Tell us what you need to demonstrate and to whom, and we will help you choose the meter, tests and sampling routine.\u003c\/p\u003e","brand":"Hygiena","offers":[{"title":"EACH","offer_id":37866148200601,"sku":"HGSS3","price":3589.34,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Hygiena-SystemSURE-Plus-ATP-Meter-Only.jpg?v=1780551137","url":"https:\/\/ccwonline.com.au\/products\/hygiena-systemsure-plus-atp-meter-only","provider":"Carpet Cleaners Warehouse","version":"1.0","type":"link"}