{"title":"Pre-order eligible","description":"\u003cp\u003eInternal: stock items (Cin7 OrderType = Order) eligible for PreOrder Globo's out-of-stock pre-order rule. Membership is driven by the preorder-ok tag.\u003c\/p\u003e","products":[{"product_id":"flex-traffic-lane-clnr-3-78ltr","title":"Bridgepoint Flex Traffic Lane Cleaner 3.78ltr","description":"\u003ch2 align=\"left\"\u003eFlex Traffic Lane Cleaner is what you need when it's time to bring in the heavy artillery. Flex is the strongest pre-spray in the Bridgepoint line.\u003c\/h2\u003e\n\u003cp align=\"left\"\u003eFlex dissolves soils and oils so quickly, that on some carpets, \u003cb\u003e\u003ci\u003eyou can actually see it working.\u003c\/i\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e“Nuke it” clean with high-powered carpet pre-spray for severely soiled carpets\u003c\/li\u003e\n\u003cli\u003eAs soon as you apply it, you can start to see it dissolve soil right before your eyes\u003c\/li\u003e\n\u003cli\u003eIdeal pre-spray for apartments, synthetic commercial carpets, and bringing dead carpets back to life\u003c\/li\u003e\n\u003cli\u003eA special blend of surfactants, alkaline builders, and boosters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp align=\"centre\" style=\"text-align: left\"\u003e\u003cb\u003eDilution Ratios:\u003c\/b\u003e 8:1 (125ml\/ltr) \u003cb\u003eRTU pH:\u003c\/b\u003e 12.5 \u003cb\u003eContains:\u003c\/b\u003e 3.78ltr \u003c\/p\u003e\n\n\u003ch2\u003epH and fibre compatibility\u003c\/h2\u003e\n\u003cp\u003eBridgepoint publish a pH figure for most products in this range, and it is the single most useful number when deciding what to put on a floor.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFibre caution\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.8 to 5.5\u003c\/td\u003e\n\u003ctd\u003eFibre set, encapsulating guards, acid rinses, protectors\u003c\/td\u003e\n\u003ctd\u003eSuits wool and natural fibre. Strongly acidic products can affect some dyes — test first.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.5 to 8\u003c\/td\u003e\n\u003ctd\u003eShampoos, fabric prespray, general cleaning\u003c\/td\u003e\n\u003ctd\u003eBroadly fibre safe including wool.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 to 10\u003c\/td\u003e\n\u003ctd\u003eEncapsulants, powders, general prespray\u003c\/td\u003e\n\u003ctd\u003eUsually fine on synthetic. Check the label before use on wool.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11 and above\u003c\/td\u003e\n\u003ctd\u003eTraffic lane cleaners, fire restoration, heavy degreasing\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSynthetic only unless the label says otherwise.\u003c\/strong\u003e High alkalinity damages wool and can cause browning on natural fibre.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRinse to a neutral or slightly acidic finish.\u003c\/strong\u003e Alkaline residue left in the pile attracts soil and can cause the carpet to resoil faster than before it was cleaned. That is what an acid rinse is for, and why the pH of the rinse matters as much as the pH of the prespray.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eCan I use this on wool?\u003c\/h3\u003e\n\u003cp\u003eCheck the pH against the table above and read the label. Products at pH 11 and above are for synthetic fibre unless Bridgepoint state otherwise. Wool tolerates a much narrower pH band than nylon, and alkaline damage is not reversible.\u003c\/p\u003e\n\u003ch3\u003eWhy does my carpet resoil quickly after cleaning?\u003c\/h3\u003e\n\u003cp\u003eUsually alkaline residue left in the pile. High pH cleaners work by breaking down soil, but anything left behind stays sticky. Rinsing to a neutral or slightly acidic finish is what prevents it.\u003c\/p\u003e\n\u003ch3\u003eDo I need to dilute exactly?\u003c\/h3\u003e\n\u003cp\u003eYes. The dilution on the label is what the published pH refers to. Running a product stronger than specified moves the pH further from neutral, which increases both cleaning power and the risk to the fibre.\u003c\/p\u003e\n\u003ch3\u003eIs the documentation Australian?\u003c\/h3\u003e\n\u003cp\u003eThe safety data sheet, label and specification sheet are Bridgepoint’s North American editions, provided for technical reference. Australian classification, transport and disposal requirements take precedence. Ask us if you need the Australian position on a specific product.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/202202-Bridgepoint_Flex_Traffic_Lane_Cleaner-CC22_7497e3dd-5d5c-4817-b4a5-580604d6e1ce.pdf?v=1770600045\" target=\"_blank\" rel=\"noopener\"\u003eSafety Data Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/BP-CC22GL-Label.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProduct Label (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/BP-CC22GL-Spec-Sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpecification Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBridgepoint documentation is published in the United States. Labels, specification sheets and cleaning guides are the North American editions and are provided for technical reference. Australian classification, transport and disposal requirements take precedence.\u003c\/p\u003e","brand":"Bridgepoint","offers":[{"title":"3.8LTR","offer_id":50672480775,"sku":"CC22GL","price":46.12,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Bridgepoint-Flex-Traffic-Lane-Cleaner-3_78ltr.jpg?v=1780550261"},{"product_id":"bearing-hiace-cds-idler","title":"Hiace CDS 4.7 idler bearing","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eBall bearing for the idler pulley in the HydraMaster CDS drive on the Toyota HiAce. HydraMaster part number 000-008-013.\u003c\/p\u003e\n\u003cp\u003eThe idler pulley carries the belt tension between the vehicle engine and the CDS pump drive. Its bearings run continuously whenever the engine is running, not just when the machine is cleaning, so they accumulate hours quickly.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIdler pulley \u003cstrong\u003e109-036\u003c\/strong\u003e in the CDS drive line\u003c\/li\u003e\n\u003cli\u003eThe pulley takes \u003cstrong\u003etwo\u003c\/strong\u003e of these bearings — one each side\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirmed against Carpet Cleaners Warehouse's own low-maintenance drive shaft (XLMDS) build sheet for the HiAce CDS, which lists 109-036 as taking 2 × 008-013.\u003c\/p\u003e\n\n\u003ch2\u003eReplace them in pairs\u003c\/h2\u003e\n\u003cp\u003eBoth bearings in an idler pulley do the same work for the same number of hours. If one is rough, the other is not far behind. Changing a single bearing means pulling the pulley twice.\u003c\/p\u003e\n\u003cp\u003eSigns the idler bearings are due: a rumble or whine from the drive that changes with engine speed rather than pump load, visible wobble in the pulley, or belt edge wear that no amount of alignment will fix.\u003c\/p\u003e\n\n\u003ch2\u003eRelated drive parts\u003c\/h2\u003e\n\u003cp\u003eOther parts in the same drive assembly that CCW stocks:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/shaft-cds-electric-clutch\"\u003eHydraMaster CDS Electric Clutch Shaft (150-009)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/electric-clutch-6-dual-groove\"\u003eElectrical Clutch 6 Dual Groove CDS (036-002)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eTwo per idler pulley. Order two.\u003c\/p\u003e\n\u003ch3\u003eWhat size bearing is it?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not publish the bearing's bore, outside diameter or width in the CDS documentation we hold, and we are not going to quote a size we cannot verify. If you need the dimensions before ordering, ask us and we will measure one off the shelf.\u003c\/p\u003e\n\u003ch3\u003eDoes it suit the CDS 4.8?\u003c\/h3\u003e\n\u003cp\u003eThe CDS 4.8 uses a different drive arrangement — a polychain belt (010-052) rather than the HiAce idler pulley setup. Do not assume this bearing carries across. Send us your machine details and we will check.\u003c\/p\u003e\n\u003ch3\u003eIs the pulley available separately?\u003c\/h3\u003e\n\u003cp\u003eIdler pulley 109-036 is not currently a stocked CCW line. Ask us if you need one and we will source it.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot sure whether your CDS uses this idler arrangement? Send us the vehicle and the machine details and we will confirm before you order.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672489863,"sku":"008-013","price":28.97,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Hiace-CDS-4_7-idler-bearing.jpg?v=1780550263"},{"product_id":"clamp-1-1-2-spring-wand-holder","title":"Wand Holder 1.5 Inch Spring Clamp","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eSpring clamp for holding a 38 mm (1½ inch) tube. It screws to a shelf, a wall panel or the inside of a van door, and the tool clips in and out by hand.\u003c\/p\u003e\n\u003cp\u003eSold singly. Most fit-outs use several.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it holds\u003c\/h2\u003e\n\u003cp\u003eAnything built on a 38 mm tube, which covers most of the hand tools in a truckmount van:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/wand-1-5inch-x-12inch-2jet-s-bend\"\u003eCMP Wand 1.5 inch × 12 inch 2 Jet S-Bend\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/westpak-wand-1-5inch-x-12inch-4jet-s-bend\"\u003eCMP Wand 1.5 inch × 12 inch 4 Jet Low Profile\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/us-products-evolution-wand-500-1-5inch-163-034\"\u003eHydraMaster EVOLUTION Wand 1.5 inch 2 Jet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pmf-titanium-wand-1-5-inch-x-12inch-4-jet-inc-teflon-glides\"\u003ePMF Mach 12 Titanium Wand 1.5 inch × 12 inch 4 Jet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/vpro-titanium-non-swivel-wand-12-x-1-5-2-jet\"\u003eVpro Titanium Non-swivel Wand 12 inch × 1.5 inch 2 Jet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStair tools and upholstery tools on the same 38 mm tube clip in equally well.\u003c\/p\u003e\n\n\u003ch2\u003eFitting\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure the tube, not the tool.\u003c\/strong\u003e The clamp is sized on the tube diameter, not on what the tool does. A 38 mm wand tube fits; a 50 mm vacuum hose does not.\u003c\/p\u003e\n\u003cp\u003eMount it where the tool can be pulled straight out rather than twisted free — a clamp behind a hose reel gets used once and then ignored. Check what is behind the panel before you drill, and use a fixing suited to the material: ply, checkerplate and a proprietary lining system each want a different answer.\u003c\/p\u003e\n\u003cp\u003eTwo clamps spaced along a long wand hold it far more securely than one in the middle, and stop it swinging on corners.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it hold a 50 mm vacuum hose?\u003c\/h3\u003e\n\u003cp\u003eNo. It is sized for a 38 mm tube.\u003c\/p\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eOne per tool as a minimum, two for a full-length wand. Most van fit-outs use several.\u003c\/p\u003e\n\u003ch3\u003eAre fixings included?\u003c\/h3\u003e\n\u003cp\u003eNo, and deliberately so — the right screw depends entirely on what you are mounting to. Ask us if you are unsure what suits your van lining.\u003c\/p\u003e\n\u003ch3\u003eCan it be mounted horizontally?\u003c\/h3\u003e\n\u003cp\u003eYes. The clip holds by spring tension on the tube, so orientation is up to you and the layout of the van.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003ePlanning a fit-out? Tell us which tools you are storing and we will work out how many clamps you need and where they are best placed.\u003c\/p\u003e\nSpring clip for 1.5 inch wand","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672502087,"sku":"033-039","price":18.91,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Wand-Holder-1_5-Inch-Spring-Clamp.jpg?v=1780550263"},{"product_id":"filter-2-5-s-s-rec-tnk-421","title":"Filter 2.5\" S\/S Recovery Tank Hydramaster Boxxer 421","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eStainless steel in-tank vacuum filter, 2½ inch MPT × 10 inch long, fitted in the recovery tank between the tank and the blower inlet. HydraMaster part number 000-049-008.\u003c\/p\u003e\n\u003cp\u003eThis is the last line of defence for the blower. Everything the wand picks up ends in the recovery tank, and the airstream leaving that tank goes straight to the vacuum blower. Debris that gets past this filter goes into the blower, and blowers do not tolerate solids.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eBoxxer 421\u003c\/strong\u003e — listed in the machine's spare parts list (078-340) as \u003cem\u003eFilter, S\/S Vacuum Pump, 2½\"\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eBoxxer 427\u003c\/strong\u003e — same spare parts list entry\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCTS450\u003c\/strong\u003e — listed as \u003cem\u003efilter, 2½\" recovery\u003c\/em\u003e in HydraMaster's suggested spares schedule\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not confuse it with 049-007, the 2 inch NPT stainless vacuum filter listed for the SpitFire, or with 049-013, the 3 inch stainless filter listed for the MAXX.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThread: 2½ inch MPT\u003c\/li\u003e\n\u003cli\u003eLength: 10 inch\u003c\/li\u003e\n\u003cli\u003eMaterial: stainless steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMaintenance\u003c\/h2\u003e\n\u003cp\u003eClean it, do not just look at it. A stainless mesh filter can appear open while the perforations are glazed with grease, fibre and detergent residue — the airflow drops long before the filter looks blocked.\u003c\/p\u003e\n\u003cp\u003eSymptoms of a blocked in-tank filter read like a vacuum leak: lift falls away at the wand, the vacuum gauge climbs while performance drops, and the machine sounds like it is working harder. Check this filter before you start looking for hose splits.\u003c\/p\u003e\n\u003cp\u003ePull it at the same interval as the filter bags and wash it through. Replace it when the mesh is torn, distorted, or too far gone to come clean — a split filter is worse than no filter, because it passes debris while looking fitted.\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/filter-s-s-vac-pump-cds-4-7\"\u003eStainless Recovery Tank Filter, CDS 4.7 (049-013)\u003c\/a\u003e — 3 inch BSP; different thread standard, does not interchange with this filter\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-s-s-vac-pump-cds-4-7\"\u003eStainless Steel Recovery Tank Filter for CDS 4.7 (049-013)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/kit-s-s-float-splash-guard\"\u003eFloat Splash Guard Kit (078-357)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eCan I run the machine without it?\u003c\/h3\u003e\n\u003cp\u003eYou can. You should not. It is protecting a blower that costs many times what the filter does.\u003c\/p\u003e\n\u003ch3\u003eDoes it replace the filter bags?\u003c\/h3\u003e\n\u003cp\u003eNo. The bags catch bulk debris in the tank; this filter catches what the bags miss on the way to the blower. Both do a job.\u003c\/p\u003e\n\u003ch3\u003eHow often should it be replaced?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster treats it as a clean-and-inspect item rather than a fixed-interval replacement. Replace on condition.\u003c\/p\u003e\n\u003ch3\u003eWill it fit a CDS or a SpitFire?\u003c\/h3\u003e\n\u003cp\u003eNot according to the parts lists we hold — those machines are documented with different filters. Ask us with your machine model before ordering.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot certain which stainless vacuum filter your machine takes? Send us the model and serial number and we will check it against the parts list.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672513159,"sku":"049-008","price":508.56,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Filter-2_5-SS-Recovery-Tank-Hydramaster-Boxxer-421.jpg?v=1780550265"},{"product_id":"filter-s-s-vac-pump-cds-4-7","title":"Stainless Steel Recovery Tank Filter for Hydramaster CDS4.7","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eStainless steel in-tank vacuum filter for the HydraMaster CDS 4.7, with a 3 inch male BSP connection. CCW part reference 049-013.\u003c\/p\u003e\n\u003cp\u003eThe filter sits in the recovery tank between the tank and the blower inlet. Everything the wand picks up ends in that tank, and the airstream leaving it goes straight to the vacuum blower. Whatever gets past this filter goes into the blower, and a blower rebuild costs many times what the filter does.\u003c\/p\u003e\n\u003ch2\u003eImportant — not interchangeable with the 2½ inch filter\u003c\/h2\u003e\n\u003cp\u003eCCW stocks two stainless in-tank filters and they do not substitute for one another:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e049-013 (this filter)\u003c\/th\u003e\n\u003cth\u003e049-008\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e3 inch male \u003cstrong\u003eBSP\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2½ inch \u003cstrong\u003eMPT\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine\u003c\/td\u003e\n\u003ctd\u003eCDS 4.7\u003c\/td\u003e\n\u003ctd\u003eBoxxer 421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe thread standards differ, not just the size. BSP and MPT will start to engage and then bind or leak, so a filter that appears close enough on the bench will not seal in the tank. Check the thread on the fitting you are removing before you order.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart reference\u003c\/td\u003e\n\u003ctd\u003e049-013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eStainless steel mesh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e3 inch male BSP thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eRecovery tank in-tank vacuum filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine\u003c\/td\u003e\n\u003ctd\u003eHydraMaster CDS 4.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMaintenance\u003c\/h2\u003e\n\u003cp\u003eInspect and clean it on a regular interval rather than when a problem appears. A partly blocked filter costs airflow gradually, so the first sign is usually longer drying times rather than an obvious loss of vacuum.\u003c\/p\u003e\n\u003cp\u003eReplace it if the mesh is torn or distorted. A torn filter passes debris straight through to the blower, which is the one thing it exists to prevent.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/filter-2-5-s-s-rec-tnk-421\"\u003eFilter 2½\" Stainless Recovery Tank (049-008)\u003c\/a\u003e — the Boxxer 421 filter, 2½ inch MPT\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/filter-bag-92-truck-mount\"\u003eFilter Bag, 7\" × 20\" (049-030)\u003c\/a\u003e — first stage, upstream of this filter\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-bag-long-narrow\"\u003eFilter Bag, 7\" × 34\" (049-028)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit a Boxxer 421?\u003c\/h3\u003e\n\u003cp\u003eNo. The Boxxer 421 filter is 049-008, 2½ inch MPT. The thread standard is different as well as the size.\u003c\/p\u003e\n\u003ch3\u003eHow often should I clean it?\u003c\/h3\u003e\n\u003cp\u003eOn a set interval. Waiting for a symptom means running restricted for some time before you notice.\u003c\/p\u003e\n\u003ch3\u003eCan I run without it while one is on order?\u003c\/h3\u003e\n\u003cp\u003eNot advisable. It is the last thing between the recovery tank and the blower.\u003c\/p\u003e\n\u003ch3\u003eDoes it replace the filter bag?\u003c\/h3\u003e\n\u003cp\u003eNo. The bag is the first stage and this is the second. They work together.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eNot sure which filter your machine takes? Send us your machine model and serial number and we will confirm the thread and size before you order.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672514439,"sku":"049-013","price":431.29,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/StainlessSteelRecoveryTankFilterforHydramasterCDS4.7.png?v=1780706770"},{"product_id":"filter-1-4-replacement-y","title":"Replacement Screen for 1\/4\" Y Filter","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eReplacement stainless screen for the ¼ inch NPT brass \"Y\" strainer used throughout HydraMaster truckmounts. HydraMaster part number 000-049-016.\u003c\/p\u003e\n\u003cp\u003eThe Y strainer sits in the high-pressure solution line and catches grit before it reaches the orifice, the pressure regulator and the jets. The screen is the consumable; the brass body is not.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eThe screen suits CCW's \u003ca href=\"\/products\/filter-1-4-inline-y-rx20-049-016\"\u003e¼ inch In-Line Y Filter (049-033)\u003c\/a\u003e and the equivalent PA065 brass strainer.\u003c\/p\u003e\n\u003cp\u003eThe Y strainer itself appears in the high-PSI manifold or by-pass assembly of every current HydraMaster truckmount we hold documentation for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoxxer 421 — 2 fitted (Hi-PSI manifold assembly, item 5)\u003c\/li\u003e\n\u003cli\u003eBoxxer 427 — 1 fitted (Hi-PSI valve assembly, item 4)\u003c\/li\u003e\n\u003cli\u003eBoxxer 423S — 2 fitted (Hi-PSI manifold assembly, item 4)\u003c\/li\u003e\n\u003cli\u003eBoxxer 318 — 2 fitted\u003c\/li\u003e\n\u003cli\u003eBoxxer 323HP — 2 fitted\u003c\/li\u003e\n\u003cli\u003eTitan 425 — 2 fitted\u003c\/li\u003e\n\u003cli\u003eMAXX 450D \/ 470D — 2 fitted (Hi-PSI manifold assembly, item 7)\u003c\/li\u003e\n\u003cli\u003eSpitFire 3.2 and 4.0 — listed in the spare parts kit\u003c\/li\u003e\n\u003cli\u003eCrossfire 4.2 — listed in the spare parts kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy it matters more than it looks\u003c\/h2\u003e\n\u003cp\u003eThe set-screw orifice downstream of this strainer is a very small hole. One piece of grit through it and you have unstable pressure, uneven flow to the jets, or a jet that will not clear. Replacing a screen is a five-minute job. Chasing a partly blocked orifice is not.\u003c\/p\u003e\n\u003cp\u003eA collapsed or split screen is the worst case, because it keeps passing solution while no longer filtering anything. Hold it up to the light: if the mesh is distorted, torn or flattened against the body, replace it.\u003c\/p\u003e\n\n\u003ch2\u003eMaintenance\u003c\/h2\u003e\n\u003cp\u003eCheck it at every service, and always after any work that opens the solution line. Machines fed from tanks, rainwater or site taps foul the screen much faster than those on clean mains water.\u003c\/p\u003e\n\u003cp\u003eBack-flush or brush it clean rather than poking at it — pushing debris through the mesh puts it where you did not want it.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this the whole filter or just the screen?\u003c\/h3\u003e\n\u003cp\u003eJust the screen. The brass body is a separate part.\u003c\/p\u003e\n\u003ch3\u003eHow many does my machine take?\u003c\/h3\u003e\n\u003cp\u003eOne or two depending on the model — see the list above. Where two are fitted, replace both.\u003c\/p\u003e\n\u003ch3\u003eCan I clean it instead of replacing it?\u003c\/h3\u003e\n\u003cp\u003eYes, until the mesh distorts or tears. It is cheap enough that most workshops keep a spare and replace rather than fight with it.\u003c\/p\u003e\n\u003ch3\u003eDoes it fit non-HydraMaster Y strainers?\u003c\/h3\u003e\n\u003cp\u003eIt is specified for the ¼ inch HydraMaster \/ PA065 strainer. Other manufacturers' strainers use their own screens. Ask us if you are unsure.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eTell us your machine model and we will confirm how many your Hi-PSI assembly takes.\u003c\/p\u003e\n\u003ch2\u003eTITAN 425 fitment\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts listing for the \u003cstrong\u003eHydraMaster TITAN 425\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHi-PSI Manifold Assembly (610-008-728) — \u003cstrong\u003e2\u003c\/strong\u003e — listed as \u003cem\u003eFilter, 1\/4\" NPT Replacement \"Y\"\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerified from the HydraMaster \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Titan_425_Parts_Listing_HQ_SEARCHABLE_LANDSCAPE_FINAL.pdf?v=1787560109\"\u003eTITAN 425 parts listing\u003c\/a\u003e, MAN-47791 Rev A.\u003c\/p\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672519111,"sku":"049-016","price":62.37,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Replacement-Screen-for-14-Y-Filter.jpg?v=1780550266"},{"product_id":"filter-bag-long-narrow","title":"Filter Bag - Long \u0026 Narrow","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eVacuum tank filter bag, long and narrow. HydraMaster part number 000-049-028, listed in HydraMaster's own accessory pages as \u003cstrong\u003e7\" × 34\"\u003c\/strong\u003e (approximately 18 cm × 86 cm).\u003c\/p\u003e\n\u003cp\u003eThe bag sits over the vacuum inlet inside the recovery tank and catches lint, fibre, hair and grit before the airstream reaches the in-tank filter and then the blower. It is the cheapest part in the vacuum path and the one doing the most work.\u003c\/p\u003e\n\n\u003ch2\u003eChoosing the right shape\u003c\/h2\u003e\n\u003cp\u003eHydraMaster lists three filter bags. They differ only in shape, and the shape has to suit the space inside your recovery tank and the position of the inlet:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e049-028\u003c\/strong\u003e — Long and Narrow, 7\" × 34\" — this bag\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-bag-92-truck-mount\"\u003e\u003cstrong\u003e049-030\u003c\/strong\u003e — Short and Narrow, 7\" × 20\"\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-bag-short-square\"\u003e\u003cstrong\u003e049-029\u003c\/strong\u003e — Short and Square, 14\" × 18\"\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e measure the tank, not the machine. Truckmounts of the same model have been built with different tank arrangements over the years. If you are ordering for a machine you have not bagged before, check what came out of it.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster part number: 000-049-028\u003c\/li\u003e\n\u003cli\u003eNominal size: 7\" × 34\" (about 18 cm × 86 cm)\u003c\/li\u003e\n\u003cli\u003eClosure: plastic cord lock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBag dimensions vary slightly between production runs. Treat the size as nominal.\u003c\/p\u003e\n\n\u003ch2\u003eOperating advice\u003c\/h2\u003e\n\u003cp\u003eEmpty it, do not just shake it. A bag that has dried out with slurry in it will not recover airflow with a shake, and a partly blocked bag costs you lift at the wand on every job that follows.\u003c\/p\u003e\n\u003cp\u003eCarry a spare and swap it on site rather than working a job with a blocked bag. Wash the used one at the end of the day.\u003c\/p\u003e\n\u003cp\u003eCheck the cord lock as well as the bag. A bag that has slipped off the inlet is doing nothing at all, and you will not know until debris turns up somewhere it should not.\u003c\/p\u003e\n\n\u003ch2\u003eThe rest of the vacuum path\u003c\/h2\u003e\n\u003cp\u003eThe bag is the first stage. Behind it sits the in-tank filter, and behind that the blower — the component the whole path exists to protect. A bag left torn or blocked simply moves the problem one stage downstream.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-2-5-s-s-rec-tnk-421\"\u003eFilter 2.5\" Stainless Recovery Tank (049-008)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-s-s-vac-pump-cds-4-7\"\u003eStainless Steel Recovery Tank Filter, CDS 4.7 (049-013)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow long does a bag last?\u003c\/h3\u003e\n\u003cp\u003eIt depends entirely on the work. Restoration and heavy commercial fill and abrade bags far faster than domestic maintenance cleaning. Replace on condition — thinning fabric, holes at the seams, or a bag that no longer comes clean.\u003c\/p\u003e\n\u003ch3\u003eDoes it replace the in-tank stainless filter?\u003c\/h3\u003e\n\u003cp\u003eNo. Both are fitted, and both do a different job.\u003c\/p\u003e\n\u003ch3\u003eCan I run two bags for extra filtration?\u003c\/h3\u003e\n\u003cp\u003eNo. Doubling up restricts airflow and costs you vacuum lift.\u003c\/p\u003e\n\u003ch3\u003eWhich bag suits my machine?\u003c\/h3\u003e\n\u003cp\u003eThe one that fits your tank and inlet. If you are unsure, measure the old bag or send us a photo of the inlet and we will tell you.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot sure which of the three shapes you need? Send us your machine model and a photo inside the recovery tank and we will pick the right one.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672522439,"sku":"049-028","price":51.73,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Filter-Bag-Long-Narrow.jpg?v=1780550266"},{"product_id":"filter-bag-short-square","title":"Filter Bag - Short \u0026 Square","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eVacuum tank filter bag, short and square. HydraMaster part number 000-049-029, listed in HydraMaster's own accessory pages as \u003cstrong\u003e14\" × 18\"\u003c\/strong\u003e (approximately 36 cm × 46 cm).\u003c\/p\u003e\n\u003cp\u003eThe bag sits over the vacuum inlet inside the recovery tank and catches lint, fibre, hair and grit before the airstream reaches the in-tank filter and then the blower. Of the three HydraMaster bags this is the one to use where the tank is shallow but wide, and a long bag would simply fold on itself.\u003c\/p\u003e\n\n\u003ch2\u003eChoosing the right shape\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e049-029\u003c\/strong\u003e — Short and Square, 14\" × 18\" — this bag\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-bag-long-narrow\"\u003e\u003cstrong\u003e049-028\u003c\/strong\u003e — Long and Narrow, 7\" × 34\"\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-bag-92-truck-mount\"\u003e\u003cstrong\u003e049-030\u003c\/strong\u003e — Short and Narrow, 7\" × 20\"\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e measure the tank, not the machine. Truckmounts of the same model have been built with different tank arrangements over the years. If you are ordering for a machine you have not bagged before, check what came out of it.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster part number: 000-049-029\u003c\/li\u003e\n\u003cli\u003eNominal size: 14\" × 18\" (about 36 cm × 46 cm)\u003c\/li\u003e\n\u003cli\u003eClosure: plastic cord lock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBag dimensions vary slightly between production runs. Treat the size as nominal.\u003c\/p\u003e\n\n\u003ch2\u003eOperating advice\u003c\/h2\u003e\n\u003cp\u003eA wide bag has more surface area than a narrow one of similar volume, which is an advantage on lint-heavy work — but only while that surface is open. Empty and wash it rather than shaking it out.\u003c\/p\u003e\n\u003cp\u003eCheck the cord lock as well as the bag. A bag that has slipped off the inlet is doing nothing at all.\u003c\/p\u003e\n\n\u003ch2\u003eThe rest of the vacuum path\u003c\/h2\u003e\n\u003cp\u003eThe bag is the first stage. Behind it sits the in-tank filter, and behind that the blower — the component the whole path exists to protect. A bag left torn or blocked simply moves the problem one stage downstream.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-2-5-s-s-rec-tnk-421\"\u003eFilter 2.5\" Stainless Recovery Tank (049-008)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-s-s-vac-pump-cds-4-7\"\u003eStainless Steel Recovery Tank Filter, CDS 4.7 (049-013)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs a wide bag better than a narrow one?\u003c\/h3\u003e\n\u003cp\u003eOnly if it suits your tank. A bag that folds, bunches or fouls the tank wall filters worse than a smaller one that hangs properly.\u003c\/p\u003e\n\u003ch3\u003eDoes it replace the in-tank stainless filter?\u003c\/h3\u003e\n\u003cp\u003eNo. Both are fitted, and both do a different job.\u003c\/p\u003e\n\u003ch3\u003eHow often should it be replaced?\u003c\/h3\u003e\n\u003cp\u003eOn condition — thinning fabric, holes at the seams, or a bag that no longer comes clean.\u003c\/p\u003e\n\u003ch3\u003eWhich bag suits my machine?\u003c\/h3\u003e\n\u003cp\u003eThe one that fits your tank and inlet. Measure the old bag, or send us a photo inside the recovery tank.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot sure which of the three shapes you need? Send us your machine model and a photo inside the recovery tank and we will pick the right one.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672526087,"sku":"049-029","price":52.52,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Filter-Bag-Short-Square.jpg?v=1780550267"},{"product_id":"filter-bag-92-truck-mount","title":"Filter Bag - Short \u0026 Narrow","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eVacuum tank filter bag, short and narrow. HydraMaster part number 000-049-030, listed in HydraMaster's own accessory pages as \u003cstrong\u003e7\" × 20\"\u003c\/strong\u003e (approximately 18 cm × 51 cm) and referred to throughout the parts lists as the \u003cem\u003e92+ Truckmount\u003c\/em\u003e filter bag.\u003c\/p\u003e\n\u003cp\u003eThis is the most widely specified of the three HydraMaster bags. It appears in the standard spare parts kit of most of the range.\u003c\/p\u003e\n\n\u003ch2\u003eMachines that list this bag\u003c\/h2\u003e\n\u003cp\u003eNamed in the spare parts list of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoxxer 421 — 2 supplied (kit 078-340)\u003c\/li\u003e\n\u003cli\u003eBoxxer 427 — 2 supplied\u003c\/li\u003e\n\u003cli\u003eSpitFire 3.2 — 1 supplied\u003c\/li\u003e\n\u003cli\u003eSpitFire 4.0 — 2 supplied (kit 078-100)\u003c\/li\u003e\n\u003cli\u003eCDS 4.2 — 6 supplied (kit 078-098)\u003c\/li\u003e\n\u003cli\u003eCDS 4.7 — listed in kit 078-099\u003c\/li\u003e\n\u003cli\u003eCrossfire 4.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CDS parts list also shows 2 bags fitted in the vacuum tank assembly itself.\u003c\/p\u003e\n\n\u003ch2\u003eChoosing the right shape\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e049-030\u003c\/strong\u003e — Short and Narrow, 7\" × 20\" — this bag\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-bag-long-narrow\"\u003e\u003cstrong\u003e049-028\u003c\/strong\u003e — Long and Narrow, 7\" × 34\"\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-bag-short-square\"\u003e\u003cstrong\u003e049-029\u003c\/strong\u003e — Short and Square, 14\" × 18\"\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e measure the tank, not the machine. Truckmounts of the same model have been built with different tank arrangements over the years.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster part number: 000-049-030\u003c\/li\u003e\n\u003cli\u003eNominal size: 7\" × 20\" (about 18 cm × 51 cm)\u003c\/li\u003e\n\u003cli\u003eClosure: plastic cord lock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBag dimensions vary slightly between production runs. Treat the size as nominal.\u003c\/p\u003e\n\n\u003ch2\u003eOperating advice\u003c\/h2\u003e\n\u003cp\u003eWhere the parts list shows two bags, run two. They are not spares kept in reserve — the machine was built expecting both inlets bagged.\u003c\/p\u003e\n\u003cp\u003eEmpty and wash rather than shaking out. A partly blocked bag costs vacuum lift on every job that follows, and the loss is gradual enough that most operators do not notice until it is significant.\u003c\/p\u003e\n\n\u003ch2\u003eThe rest of the vacuum path\u003c\/h2\u003e\n\u003cp\u003eThe bag is the first stage. Behind it sits the in-tank filter, and behind that the blower — the component the whole path exists to protect. A bag left torn or blocked simply moves the problem one stage downstream.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-2-5-s-s-rec-tnk-421\"\u003eFilter 2.5\" Stainless Recovery Tank (049-008)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/filter-s-s-vac-pump-cds-4-7\"\u003eStainless Steel Recovery Tank Filter, CDS 4.7 (049-013)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does \"92+ Truckmount\" mean?\u003c\/h3\u003e\n\u003cp\u003eIt is HydraMaster's own long-standing description for this bag, dating to their 1992-onwards truckmount range. It is a naming convention, not a size.\u003c\/p\u003e\n\u003ch3\u003eHow many should I keep on the van?\u003c\/h3\u003e\n\u003cp\u003eAt least one spare set. Swapping a blocked bag on site takes a minute; working a whole job down on vacuum costs far more.\u003c\/p\u003e\n\u003ch3\u003eDoes it replace the in-tank stainless filter?\u003c\/h3\u003e\n\u003cp\u003eNo. Both are fitted, and both do a different job.\u003c\/p\u003e\n\u003ch3\u003eWhich bag suits my machine?\u003c\/h3\u003e\n\u003cp\u003eThe one that fits your tank and inlet. Measure the old bag, or send us a photo inside the recovery tank.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot sure which of the three shapes you need? Send us your machine model and a photo inside the recovery tank and we will pick the right one.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672529927,"sku":"049-030","price":58.91,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Filter-Bag-Short-Narrow.jpg?v=1780550267"},{"product_id":"4ma-6ufs","title":"1\/4\" Male Angle x 3\/8\" Universal Female Fitting (052-014) 4MA-6UFS","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eBrass fitting, ¼ inch male angle × 3\/8 inch universal female swivel. HydraMaster part number 000-052-014, coded \u003cstrong\u003e4MA-6UFS\u003c\/strong\u003e in HydraMaster's fitting reference.\u003c\/p\u003e\n\u003cp\u003eThe universal female swivel end seats on a cone rather than on tapered thread, so the joint can be made and broken repeatedly without tape or sealant and without the fitting winding itself tight in the wrong orientation. The angled male end lets a hose leave a fitting at 90 degrees instead of fighting a bend.\u003c\/p\u003e\n\n\u003ch2\u003eReading the HydraMaster fitting code\u003c\/h2\u003e\n\u003cp\u003eHydraMaster's fitting codes are consistent once you know them, and knowing them saves ordering the wrong part:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e = ¼ inch, \u003cstrong\u003e6\u003c\/strong\u003e = 3\/8 inch, \u003cstrong\u003e8\u003c\/strong\u003e = ½ inch (sixteenths of an inch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM\u003c\/strong\u003e = male, \u003cstrong\u003eMA\u003c\/strong\u003e = male angle, \u003cstrong\u003eUFS\u003c\/strong\u003e = universal female swivel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSo \u003cstrong\u003e4MA-6UFS\u003c\/strong\u003e reads as ¼ inch male angle to 3\/8 inch universal female swivel.\u003c\/p\u003e\n\n\u003ch2\u003eThe rest of the angle family\u003c\/h2\u003e\n\u003cp\u003eHydraMaster list these male-angle fittings alongside it. They are easy to confuse and none of them will make up correctly on the wrong thread:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2MA-2UFS — 052-002\u003c\/li\u003e\n\u003cli\u003e2MA-4UFS — 052-004\u003c\/li\u003e\n\u003cli\u003e4MA-4UFS — 052-006\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4MA-6UFS — 052-014 (this part)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e6MA-4UFS — 052-017\u003c\/li\u003e\n\u003cli\u003e6MA-6UFS — 052-020\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCheck both ends before ordering.\u003c\/strong\u003e The difference between 4MA-6UFS and 6MA-4UFS is which end is which, and they are not interchangeable.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eDo not put thread tape on the universal swivel end. It seals on the cone, and tape on that face is a leak, not a seal. The male NPT end does take sealant.\u003c\/p\u003e\n\u003cp\u003eNip the swivel firm, not hard. You are seating two machined faces, not stretching a thread.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat pressure will it take?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not publish a pressure rating for the individual fitting in the documentation we hold, and we will not quote one we cannot verify. It is specified as part of truckmount solution plumbing. Ask us if you need a rated figure for a particular application.\u003c\/p\u003e\n\u003ch3\u003eIs it brass or stainless?\u003c\/h3\u003e\n\u003cp\u003eBrass, consistent with the rest of the HydraMaster standard fitting range.\u003c\/p\u003e\n\u003ch3\u003eDoes it need an O-ring?\u003c\/h3\u003e\n\u003cp\u003eThe universal swivel seals metal to metal on the cone. If yours is weeping after being nipped up, inspect the cone face for damage rather than looking for a seal.\u003c\/p\u003e\n\u003ch3\u003eWill it suit non-HydraMaster equipment?\u003c\/h3\u003e\n\u003cp\u003eThe threads are standard NPT sizes, so it often will. Confirm both ends against what you are joining before you order.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eWorking out a fitting run? Tell us what is at each end and we will spec the fittings for you rather than have you order twice.\u003c\/p\u003e\n\u003ch2\u003eRelated fittings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/bushing-mod-set-screw-orifice\"\u003eBushing, Modified Orifice Housing (052-423)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/nipple-3-4inch-npt-3-4-garden\"\u003eNipple 3\/4 inch NPT to Garden Hose (052-281)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/elbow-2-barb-x-2-f-port\"\u003eElbow 2\" Barb × 2\" FPT (052-222)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672532359,"sku":"052-014","price":11.73,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/14-Male-Angle-x-38-Universal-Female-Fitting-052-014-4MA-6UFS.jpg?v=1780550267"},{"product_id":"elbow-2-barb-x-2-f-port","title":"Elbow 2\" Barb X 2\" F Port","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eElbow, 2 inch barb to 2 inch female port, listed by HydraMaster as \u003cem\u003eElbow, 2\" Comb — Insert x FPT\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt connects the vacuum hose to the recovery tank lid.\u003c\/p\u003e\n\u003ch2\u003eWhere it is fitted\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRecovery tank lid assembly — \u003cstrong\u003e2 per machine\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFitted with 2\" NPT to 2\" female slip adapter 052-219 and bulkhead gasket 057-015\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVerified fitment — current machines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hydramaster-boxxer-318hp-1500psi-in-the-boxgloves-off-pricing\"\u003eBoxxer 318HP\u003c\/a\u003e — 70 gallon recovery tank cover, and 100 gallon cover (2 port)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hydramaster-titan-575\"\u003eTITAN 575HP\u003c\/a\u003e — recovery tank cover assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hydramaster-tmtg-4000-in-the-box\"\u003eTMTG4000\u003c\/a\u003e — 70 gallon URT cover (1 port)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuantity follows the cover, not the machine.\u003c\/strong\u003e A one-port cover takes one elbow; a two-port cover takes two. The 70 gallon URT cover is listed as 1 port and the 100 gallon as 2 port, so check the cover in front of you rather than assuming from tank size.\u003c\/p\u003e\n\u003cp\u003eVerified from the HydraMaster parts books: Boxxer 318HP MAN-46586 Rev C and TMTG4000 MAN-47717 Rev B.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gasket-1-1-2-bulkhead-fitting\"\u003eGasket 1 1\/2 Bulkhead Fitting (057-015)\u003c\/a\u003e — fitted at the same joint\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gasket-tank-adapter\"\u003eGasket for Recovery Tank Adapter (057-206)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eOne per port on the recovery tank cover. Count the ports.\u003c\/p\u003e\n\u003ch3\u003eDoes it fit both the 70 and 100 gallon tanks?\u003c\/h3\u003e\n\u003cp\u003eYes. The elbow is common to both; only the number of ports changes.\u003c\/p\u003e\n\u003ch3\u003eShould I replace the bulkhead gasket at the same time?\u003c\/h3\u003e\n\u003cp\u003eYes. Once disturbed, a compressed bulkhead gasket will not seal reliably again, and it is a low-cost item.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eSend us your machine model and serial number and we will confirm the fitting set before you order.\u003c\/p\u003e\u003ch2\u003eIdentifying the right part\u003c\/h2\u003e\n\u003cp\u003eCCW part codes are the HydraMaster part number with the \u003ccode\u003e000-\u003c\/code\u003e prefix removed — this item is HydraMaster P\/N \u003cstrong\u003e000-052-222\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eHydraMaster truckmounts share components across models and production years. If you are ordering for an existing machine, send us the model and serial number from the data plate and we will check it against the parts list for your machine.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster \u003cstrong\u003eCDS 4.2 \/ 4.7\u003c\/strong\u003e machine assemblies and parts lists. Fitment to other HydraMaster models has not been verified from a parts list — ask us if you are ordering for a different machine.\u003c\/p\u003e\u003chr\u003e\u003cdiv class=\"tabbable\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv class=\"tab-pane active\" id=\"description\"\u003e\n\n\u003cp\u003e90° Elbow - 2\" FPT × 2\" Barb \u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eTITAN 425 fitment\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts listing for the \u003cstrong\u003eHydraMaster TITAN 425\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e70 gallon URT cover assembly (610-029-726) — \u003cstrong\u003e1\u003c\/strong\u003e — one port\u003c\/li\u003e\n\u003cli\u003e100 gallon URT cover assembly (610-029-002) — \u003cstrong\u003e2\u003c\/strong\u003e — two ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerified from the HydraMaster \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Titan_425_Parts_Listing_HQ_SEARCHABLE_LANDSCAPE_FINAL.pdf?v=1787560109\"\u003eTITAN 425 parts listing\u003c\/a\u003e, MAN-47791 Rev A.\u003c\/p\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672542215,"sku":"052-222","price":55.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Elbow-2-Barb-X-2-F-Port.jpg?v=1780550268"},{"product_id":"nipple-3-4inch-npt-3-4-garden","title":"Nipple 3\/4 inch NPT 3\/4 Garden","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eNipple, 3\/4 inch NPT to 3\/4 inch male garden hose, listed by HydraMaster as \u003cem\u003eNipple, 3\/4\" NPT X 3\/4\" Male Garden Hose\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt adapts the automatic pump-out line to a standard garden hose thread so waste can be discharged through ordinary hose.\u003c\/p\u003e\n\u003ch2\u003eWhere it is fitted\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDura-Flow APO pump assembly — \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eChemical jug tray assembly — \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e85 gallon rotomoulded tank installation — \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eUsed with swing check valve 000-169-009, garden hose gasket 000-057-055 and cap 000-027-014\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVerified fitment — current machines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hydramaster-boxxer-318hp-1500psi-in-the-boxgloves-off-pricing\"\u003eBoxxer 318HP\u003c\/a\u003e — AWDS Universal Kit Assembly (Figure 9-33), \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hydramaster-titan-575\"\u003eTITAN 575HP\u003c\/a\u003e — AWDS Universal Kit Assembly (Figure 9-45), \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hydramaster-tmtg-4000-in-the-box\"\u003eTMTG4000\u003c\/a\u003e — Dump \/ Vacuum Bracket Assembly (Figure 9-32), \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant — on the Boxxer 318HP and TITAN 575HP this is part of the AWDS kit, not the base machine.\u003c\/strong\u003e If your machine has no automatic wastewater disposal system fitted, this nipple will not be present. On the TMTG4000 it sits in the dump and vacuum bracket assembly instead.\u003c\/p\u003e\n\u003cp\u003eVerified from the HydraMaster parts books: Boxxer 318HP MAN-46586 Rev C and TMTG4000 MAN-47717 Rev B.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/valve-3-4-swing-check-cvp\"\u003e3\/4 Swing Check CVP Valve (169-009)\u003c\/a\u003e — fitted in the same line\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/kit-awds-universal-auto-pump-out-ac12e-ss68-158s-comet\"\u003eAutomatic Wastewater Disposal System (AWDS) Kit (079-220)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhy a garden hose thread?\u003c\/h3\u003e\n\u003cp\u003eSo waste can be discharged through ordinary garden hose rather than a proprietary fitting — practical on site, and easy to replace anywhere.\u003c\/p\u003e\n\u003ch3\u003eDo I need the check valve as well?\u003c\/h3\u003e\n\u003cp\u003eThey are fitted in the same line. If the pump-out will not prime after sitting, the check valve is the more likely fault of the two.\u003c\/p\u003e\n\u003ch3\u003eIs it brass?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster lists the material as brass in the assembly parts list.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eNot sure whether your machine has AWDS fitted? Send us the model and serial number and we will check.\u003c\/p\u003e\u003ch2\u003eIdentifying the right part\u003c\/h2\u003e\n\u003cp\u003eHydraMaster truckmounts share many components across models and across production years. Part numbers in the CCW catalogue are the HydraMaster part number with the \u003ccode\u003e000-\u003c\/code\u003e prefix removed — this item is HydraMaster P\/N \u003cstrong\u003e000-052-281\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIf you are ordering for an existing machine, check the model and serial number on the data plate and send them to us. We will confirm the part against the parts list for your machine before you order.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster \u003cstrong\u003eBoxxer 421\u003c\/strong\u003e machine assemblies and parts lists (drawing set D-5057 \/ D-6861). Fitment to other HydraMaster models has not been verified from a parts list — ask us if you are ordering for a different machine.\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003eSame as BR319\u003c\/p\u003e\n\u003ch2\u003eTITAN 425 fitment\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts listing for the \u003cstrong\u003eHydraMaster TITAN 425\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAWDS Universal Kit Assembly (000-079-220 Rev E) — \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerified from the HydraMaster \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Titan_425_Parts_Listing_HQ_SEARCHABLE_LANDSCAPE_FINAL.pdf?v=1787560109\"\u003eTITAN 425 parts listing\u003c\/a\u003e, MAN-47791 Rev A.\u003c\/p\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672556743,"sku":"052-281","price":50.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Nipple-34-inch-NPT-34-Garden.jpg?v=1780550269"},{"product_id":"bushing-mod-set-screw-orifice","title":"Bushing Modified Orifice Housing (Brass)","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eModified brass orifice housing bushing. HydraMaster part number 000-052-423, listed as \u003cem\u003eBushing, Modified Set Screw Orifice\u003c\/em\u003e and, in newer manuals, \u003cem\u003eFitting, Bushing Modified Orifice Housing\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe bushing houses the set-screw orifice that meters solution flow in the high-pressure manifold. It is not an ordinary reducing bushing — it is machined to accept the orifice set screw, which is why an off-the-shelf bushing of the same thread sizes will not do the job.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eNamed in the Hi-PSI manifold assembly of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoxxer 421 — item 4, 2 fitted\u003c\/li\u003e\n\u003cli\u003eBoxxer 427 — item 3, 1 fitted\u003c\/li\u003e\n\u003cli\u003eBoxxer 423S — item 5, 2 fitted\u003c\/li\u003e\n\u003cli\u003eBoxxer 318 — 2 fitted\u003c\/li\u003e\n\u003cli\u003eBoxxer 323HP — 1 fitted\u003c\/li\u003e\n\u003cli\u003eTitan 425 — 2 fitted\u003c\/li\u003e\n\u003cli\u003eMAXX 450D \/ 470D \/ Diesel — item 4, 2 fitted\u003c\/li\u003e\n\u003cli\u003eCrossfire 4.2 — \u003cem\u003eBushing, Mod. Set Screw Orifice Housing\u003c\/em\u003e, 1 fitted\u003c\/li\u003e\n\u003cli\u003eDriMaster Rotary tool — item 11, 1 fitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat goes with it\u003c\/h2\u003e\n\u003cp\u003eThe orifice set screw itself is a separate part, and the size of that screw is what determines flow:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/orifice-regulator-sf4-0-setscrew\"\u003e\u003cstrong\u003e180-004\u003c\/strong\u003e — Orifice, Set Screw 0.033\"\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e180-006\u003c\/strong\u003e — Orifice, Set Screw 0.061\" (not currently a stocked CCW line)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMachines are built with a specific orifice size. Changing it changes solution flow and pressure behaviour. Do not fit a different size on assumption — check the parts list for your model.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eNote the orientation and the depth of the orifice screw before you strip the assembly, and take a photo. It is the sort of detail that is obvious while the parts are in front of you and impossible to reconstruct afterwards.\u003c\/p\u003e\n\u003cp\u003eCheck the assembly drawing for your machine for the sealant specification. HydraMaster call it out explicitly on the manifold drawings, and it is not the same on every joint.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eDoes it come with the orifice screw?\u003c\/h3\u003e\n\u003cp\u003eNo. The set screw is a separate part number — 180-004 or 180-006 depending on the machine.\u003c\/p\u003e\n\u003ch3\u003eCan I use a standard brass reducing bushing?\u003c\/h3\u003e\n\u003cp\u003eNo. This one is machined to house the orifice set screw. A standard bushing will not hold it.\u003c\/p\u003e\n\u003ch3\u003eHow many does my machine take?\u003c\/h3\u003e\n\u003cp\u003eOne or two depending on the model — see the list above.\u003c\/p\u003e\n\u003ch3\u003eMy pressure is unstable. Is this the part?\u003c\/h3\u003e\n\u003cp\u003ePossibly, but check the simple things first: the ¼ inch Y strainer screen, the orifice itself, and the by-pass valve seals. An unstable reading is more often a blocked orifice or worn by-pass seals than a failed bushing.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eRebuilding a Hi-PSI manifold? Send us the machine model and serial number and we will put together the full set of parts from the assembly drawing so nothing is missed.\u003c\/p\u003e\n\u003ch2\u003eTITAN 425 fitment\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts listing for the \u003cstrong\u003eHydraMaster TITAN 425\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHi-PSI Manifold Assembly (610-008-728) — \u003cstrong\u003e2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerified from the HydraMaster \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Titan_425_Parts_Listing_HQ_SEARCHABLE_LANDSCAPE_FINAL.pdf?v=1787560109\"\u003eTITAN 425 parts listing\u003c\/a\u003e, MAN-47791 Rev A.\u003c\/p\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672560263,"sku":"052-423","price":56.23,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Bushing-Modified-Orifice-Housing-Brass.jpg?v=1780550270"},{"product_id":"nipple-1-8-x-4-s-steel-rx20","title":"HydraMaster RX20 Stainless Steel Nipple 1\/8\" X 4\"","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eStainless steel nipple, 1\/8\" NPT × 4\" long, for the HydraMaster RX-20 rotary extractor. HydraMaster part number 000-052-515, listed as \u003cem\u003eNipple, 1\/8\" NPT × 4\" Lg.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe nipples carry solution out to the jets on the rotary head.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThread: 1\/8\" NPT\u003c\/li\u003e\n\u003cli\u003eLength: 4 inches\u003c\/li\u003e\n\u003cli\u003eHydraMaster part number: 000-052-515\u003c\/li\u003e\n\u003cli\u003eMaterial: stainless steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree fitted per machine\u003c\/strong\u003e — order accordingly if you are rebuilding the head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhich RX-20 does this fit?\u003c\/h2\u003e\n\u003cp\u003eHydraMaster has built the RX-20 since the 1980s and there have been many revisions. Carpet Cleaners Warehouse supplies the current machine, the \u003cstrong\u003eRX20 NEXTGEN, model 700-041-036\u003c\/strong\u003e (CE, 230 V, 50 Hz).\u003c\/p\u003e\n\u003cp\u003eThe current owner's manual, MAN-47328 Rev. B (March 2019), covers models 700-041-030, -031, -032, -035, \u003cstrong\u003e-036\u003c\/strong\u003e, -330, -331, -332, -333, -334 and -407. Earlier machines are covered by their own editions, going back to c. 1987.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, check the model number on your machine's data plate.\u003c\/strong\u003e If you are unsure, contact us with the number and we will confirm the correct part.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster parts lists in the 2011 owner’s manual (models 700-041-006 and -007), the 2014 edition (700-041-006, -007, -014, -316, -318 and -322) and the current 2019 NEXTGEN edition, MAN-47328 Rev. B.\u003c\/p\u003e\n\u003cp\u003eIn the NEXTGEN parts lists it is item 9 of vacuum head assembly 604-053-100, in stainless steel, \u003cstrong\u003ethree per machine\u003c\/strong\u003e. That assembly is fitted to every NEXTGEN variant, including the CE 230 V 50 Hz machine, model 700-041-036, which is the one we supply.\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003eThis item replaces 052-080.\u003c\/p\u003e\n\n\u003cp\u003eQuantities verified from the RX-20 owner’s manual MAN-47328 Rev. B (March 2019), Vacuum Head Assembly and Vacuum Shoe \u0026amp; Skid Assembly parts lists.\u003c\/p\u003e\n\u003ch2\u003eRelated RX-20 parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gasket-rx20-vacuum-head\"\u003eRX20 Vacuum Head Gasket (057-048)\u003c\/a\u003e — 5 per machine\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/rx20-head-4inch-shoe-one-piece\"\u003eRX20 4in Cast Shoe (064-030)\u003c\/a\u003e — 5 per machine\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hose-vac-hub-skid-rx-20\"\u003eRX20 1in Vacuum Hose (068-174)\u003c\/a\u003e — 5 per machine\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gasket-rx-20-felt-hub\"\u003eRX20 Felt Hub Gasket (057-047)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/switch-micro-rx20\"\u003eRX20 Micro Switch (157-032)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eThree per machine. Order the set if you are rebuilding the head.\u003c\/p\u003e\n\u003ch3\u003eWhy stainless rather than brass?\u003c\/h3\u003e\n\u003cp\u003eThe nipples carry solution to the jets and sit in the wet path. Stainless resists the chemistry better over a working life.\u003c\/p\u003e\n\u003ch3\u003eDo the jets come with it?\u003c\/h3\u003e\n\u003cp\u003eNo. The full cone jets are a separate part, also three per machine.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/RX-20_20190301_Manual.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOwner’s Manual — MAN-47328 Rev. B, March 2019 (PDF, 15 MB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis manual covers models 700-041-030, -031, -032, -035, -036, -330, -331, -332, -333, -334 and -407. If your machine is older, contact us with the model number from the data plate and we will send the edition that matches it.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672560711,"sku":"052-515","price":28.26,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/HydraMaster-RX20-Stainless-Steel-Nipple-18-X-4.jpg?v=1780550270"},{"product_id":"hose-cuff-2-5-inch","title":"Hose Cuff 2.5 Inch","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eScrew cuff for 2.5 inch (63mm) vacuum hose. This one is \u003cstrong\u003ePVC rather than soft vinyl\u003c\/strong\u003e — it is a genuine Flexaust part, 03100800, from their Genesis range.\u003c\/p\u003e\u003cp\u003e2.5 inch is the large-bore size used where airflow matters more than handling: long runs, high-lift machines and waste extraction.\u003c\/p\u003e\n\u003ch2\u003eThread and Slip — Not Male and Female\u003c\/h2\u003e\n\u003cp\u003eStandard vacuum hose cuffs are specified as \u003cstrong\u003ethread x slip\u003c\/strong\u003e, and getting this straight removes most of the confusion in this part of the catalogue.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003ethreaded end screws onto the vacuum hose\u003c\/strong\u003e. It engages the external helix of the hose itself, which is why it grips.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eslip end is a plain socket\u003c\/strong\u003e that pushes onto the wand or tool tube.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThere is no male or female option on a standard screw cuff.\u003c\/strong\u003e That terminology belongs to the Flash Cuff quick-connect range, which is a different and non-interchangeable system. If someone has told you to order a \"female 1.5 inch cuff\", they most likely mean a Flash Cuff.\u003c\/p\u003e\n\u003cp\u003eWorth knowing: there is \u003cstrong\u003eno published thread standard, pitch or TPI\u003c\/strong\u003e for vacuum cuff threads, from any manufacturer we can find. The pitch is set by the helix of the hose, not by a fitting standard. Cuffs from different makers usually interchange, but test the joint before you rely on it.\u003c\/p\u003e\n\u003ch2\u003eCuff, Mender or Connector — Which Do You Need?\u003c\/h2\u003e\n\u003cp\u003eThree different parts, routinely bought in error for one another.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eJoins\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHow\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose \u003cstrong\u003ecuff\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eHose to \u003cstrong\u003etool or wand\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eThreaded end onto the hose, slip end onto the tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose \u003cstrong\u003emender\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eHose to \u003cstrong\u003ehose\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eThreaded both ends — screws straight onto two bare hose ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVC \u003cstrong\u003econnector\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCuff to cuff\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarbed both ends — the cuffs already fitted to each hose slip over it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eThe one that catches people out is the PVC connector.\u003c\/strong\u003e It does not join two bare hose ends. It needs a cuff already fitted to each hose, and the barbs are there for those cuffs to slide over. So a PVC join is four parts — two hoses, two cuffs, one connector. A mender is two hoses and one mender, and nothing else.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCCW SKU\u003c\/td\u003e\n\u003ctd\u003eAH220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003e2.5 inch thread (hose) x 2.5 inch slip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eGrey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFlexaust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer part\u003c\/td\u003e\n\u003ctd\u003e03100800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14kg (0.30 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature rating\u003c\/td\u003e\n\u003ctd\u003eNot stated by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhich end goes on the hose?\u003c\/h3\u003e\n\u003cp\u003eThe threaded end. It screws onto the outside of the hose and engages the hose helix. The plain slip end pushes onto the wand or tool.\u003c\/p\u003e\n\u003ch3\u003eIs it male or female?\u003c\/h3\u003e\n\u003cp\u003eNeither — standard screw cuffs are thread and slip, not male and female. See the note above.\u003c\/p\u003e\n\u003ch3\u003eWill it fit hose from another supplier?\u003c\/h3\u003e\n\u003cp\u003eOn the hose side, 63mm is 63mm, so almost certainly. There is no published thread standard, so test the joint before you rely on it on a job.\u003c\/p\u003e\n\u003ch3\u003eHow do I fit it?\u003c\/h3\u003e\n\u003cp\u003eWarm the cuff and work it onto the hose end, turning it so it follows the helix. Warm water is enough on soft vinyl. Do not force a cold cuff — that is how hose ends get damaged.\u003c\/p\u003e\n\u003ch3\u003eMy cuff keeps pulling off. Why?\u003c\/h3\u003e\n\u003cp\u003eUsually the hose has been cut mid-helix so there is nothing for the thread to grip, or the hose end has gone oval from heat. Cut back a clean turn and refit.\u003c\/p\u003e\n\u003ch3\u003eWhat if I need to join two hoses instead?\u003c\/h3\u003e\n\u003cp\u003eThat is a mender, not a cuff — see \u003ca href=\"https:\/\/ccwonline.com.au\/products\/hose-mender-2-inch-thread-to-2inch-thread\"\u003eHose Mender 2 Inch (AH49)\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ccwonline.com.au\/products\/connector-2-5inch-2-5inch-pvc-052-588\"\u003ePVC Connector 2.5 Inch (AH222)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ccwonline.com.au\/products\/hose-cuff-2-inch\"\u003eHose Cuff 2 Inch (AH44)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/ccwonline.com.au\/products\/swivel-cuff-2-inch\"\u003eSwivel Cuff 2 Inch (AH39)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat We See in the Field\u003c\/h2\u003e\n\u003cp\u003eWhen vacuum fades gradually, check the cuffs, hose ends and joins before blaming the blower or vacuum motors. If the hose end is stretched or cracked, cut it back to sound material before fitting the new cuff.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eRunning 2.5 inch hose? Tell us the tool end and we will confirm the fitting.\u003c\/p\u003e","brand":"Hydroforce","offers":[{"title":"EACH","offer_id":50672564999,"sku":"AH220","price":29.45,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Hose-Cuff-2_5-Inch.jpg?v=1780550271"},{"product_id":"gasket-1-1-2-bulkhead-fitting","title":"Gasket 1 1\/2 Bulkhead Fitting","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eBulkhead fitting gasket, 1½ inch, for the HydraMaster recovery tank cover — listed as \u003cem\u003eGasket, 1-1\/2\" Bulkhead Fitting\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eOne is fitted per cover on both the 70 and 100 gallon tanks. Replace it whenever the cover is removed for tank service. It is a low-cost item, and refitting a compressed gasket is a common cause of a vacuum leak that appears immediately after a service.\u003c\/p\u003e\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eNamed in the current parts books for the \u003ca href=\"\/products\/hydramaster-boxxer-318hp-1500psi-in-the-boxgloves-off-pricing\"\u003eHydraMaster Boxxer 318HP\u003c\/a\u003e, \u003ca href=\"\/products\/hydramaster-titan-575\"\u003eTITAN 575HP\u003c\/a\u003e and \u003ca href=\"\/products\/hydramaster-tmtg-4000-in-the-box\"\u003eTMTG4000\u003c\/a\u003e, and fitted to earlier machines using the same Universal Recovery Tank.\u003c\/p\u003e\n\u003cp\u003eHydraMaster calls the tank a Universal Recovery Tank (URT) in its parts books; CCW and much of the trade still call it the Airmax tank. They are the same tank.\u003c\/p\u003e\n\u003ch2\u003eThe full cover gasket set\u003c\/h2\u003e\n\u003cp\u003eHydraMaster specifies a different set for each tank size. The side gasket is the part that changes, and the middle gasket quantity changes with it.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eGasket\u003c\/th\u003e\n\u003cth\u003eHydraMaster P\/N\u003c\/th\u003e\n\u003cth\u003e70 gallon\u003c\/th\u003e\n\u003cth\u003e100 gallon\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnd, recovery tank cover\u003c\/td\u003e\n\u003ctd\u003e000-057-202\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMiddle, recovery tank cover\u003c\/td\u003e\n\u003ctd\u003e000-057-203\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide, recovery tank\u003c\/td\u003e\n\u003ctd\u003e000-057-204\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide, recovery tank cover\u003c\/td\u003e\n\u003ctd\u003e000-057-205\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1½\" bulkhead fitting\u003c\/td\u003e\n\u003ctd\u003e000-057-015\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter, URT\u003c\/td\u003e\n\u003ctd\u003e000-057-206\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eVerified from the recovery tank cover assemblies in the Boxxer 318HP parts book (MAN-46586 Rev C). CCW lists the middle, 70 gallon side, bulkhead and adapter gaskets. For the end gasket (000-057-202) or the 100 gallon side gasket (000-057-205), contact us with your machine model and serial number.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gasket-middle-airmax-tank\"\u003eMiddle Gasket for Hydramaster Airmax Recovery Tank (057-203)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gasket-side-airmax-tank\"\u003eSide Gasket for Hydramaster 70Gal Airmax Recovery Tank (057-204)\u003c\/a\u003e — 70 gallon tanks only\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gasket-tank-adapter\"\u003eGasket for Recovery Tank Adapter (057-206)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eOne per cover, on either tank size.\u003c\/p\u003e\n\u003ch3\u003eIs it the same on the 70 and 100 gallon tanks?\u003c\/h3\u003e\n\u003cp\u003eYes. This is one of the parts that does not change with tank size.\u003c\/p\u003e\n\u003ch3\u003eDo I need to replace it every service?\u003c\/h3\u003e\n\u003cp\u003eReplace it whenever the bulkhead fitting is disturbed. Once compressed, it will not seal reliably a second time.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eSend us your machine model and serial number and we will confirm the correct gasket set before you order.\u003c\/p\u003e\n\u003ch2\u003eTITAN 425 fitment\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts listing for the \u003cstrong\u003eHydraMaster TITAN 425\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e70 gallon URT cover assembly (610-029-726) — \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e100 gallon URT cover assembly (610-029-002) — \u003cstrong\u003e2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerified from the HydraMaster \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Titan_425_Parts_Listing_HQ_SEARCHABLE_LANDSCAPE_FINAL.pdf?v=1787560109\"\u003eTITAN 425 parts listing\u003c\/a\u003e, MAN-47791 Rev A.\u003c\/p\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672569031,"sku":"057-015","price":18.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Gasket-1-12-Bulkhead-Fitting.jpg?v=1780550272"},{"product_id":"gasket-p-220-exhaust-man","title":"Briggs \u0026 Stratton Exhaust Manifold Gasket P-220","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eExhaust manifold gasket for the Briggs \u0026amp; Stratton P-220 engine. HydraMaster part number 000-057-016, listed as \u003cem\u003eGasket, P-220 Exhaust Manifold\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo are required per engine.\u003c\/strong\u003e HydraMaster's own parts lists show them fitted in pairs.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 4.0\u003c\/strong\u003e — engine assembly items 33 and 38, 2 fitted; also item 67 in the machine assembly\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 3.2\u003c\/strong\u003e — item 18, 2 fitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not confuse it with \u003cstrong\u003e057-010\u003c\/strong\u003e, \u003cem\u003eGasket, Exhaust Manifold — Vanguard\u003c\/em\u003e, which is listed as item 13 in the same SpitFire 3.2 assembly. The two gaskets sit in the same exhaust system and are not the same part.\u003c\/p\u003e\n\n\u003ch2\u003eWhy exhaust gaskets are worth doing properly\u003c\/h2\u003e\n\u003cp\u003eAn exhaust leak on a truckmount engine is not just a noise problem. On a machine that heats solution from exhaust or engine heat, a leaking manifold joint changes the heat available and shows up as inconsistent solution temperature. In a van, an exhaust leak is a safety matter before it is a performance one.\u003c\/p\u003e\n\u003cp\u003eManifold gaskets fail from heat cycling rather than hours, so a machine that is started and stopped many times a day will go through them faster than the hour meter suggests.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eReplace both gaskets together, and replace them whenever the manifold comes off — a used exhaust gasket has already taken its set and will not seal the same joint twice.\u003c\/p\u003e\n\u003cp\u003eClean both faces properly and check the manifold face for distortion before you reassemble. A warped flange will leak through a new gasket, and you will be doing the job again.\u003c\/p\u003e\n\u003cp\u003eTorque the fasteners evenly and in sequence. Exhaust fasteners work loose with heat cycling — check them again after the first few hours of running.\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gasket-exhaust-donut-1-5\"\u003eGasket Exhaust Donut 1.5\" (057-177)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gasket-4-bolt-ext-div-flange\"\u003eGasket 4 Bolt Exhaust Diverter Flange (057-146)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eTwo per engine.\u003c\/p\u003e\n\u003ch3\u003eIs this the Vanguard gasket?\u003c\/h3\u003e\n\u003cp\u003eNo. The Vanguard exhaust manifold gasket is 057-010, a different part.\u003c\/p\u003e\n\u003ch3\u003eCan I re-use the old one if it looks intact?\u003c\/h3\u003e\n\u003cp\u003eNo. It has already conformed to the old joint under heat and pressure.\u003c\/p\u003e\n\u003ch3\u003eWhat material is it?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not state the gasket material in the parts lists we hold, so we are not going to guess. Ask us if the specification matters for your application.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eDoing an exhaust job? Tell us the machine and we will check the parts list for the fasteners, donut gasket and diverter flange gasket you may also need.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672574727,"sku":"057-016","price":98.55,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Briggs-Stratton-Exhaust-Manifold-Gasket-P-220.jpg?v=1780550272"},{"product_id":"gasket-valve-cover-fd620d","title":"Kawasaki FD620D Valve Cover Gasket","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eValve cover gasket for the Kawasaki FD620D engine. HydraMaster part number 000-057-023.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo are required per engine\u003c\/strong\u003e — the FD620D is a V-twin, with one valve cover per cylinder head.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eKawasaki \u003cstrong\u003eFD620D\u003c\/strong\u003e engines as fitted to HydraMaster truckmounts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe have not located this part number in the HydraMaster machine parts lists we hold, so we cannot list the specific truckmount models it appears in. What we can state is the engine it belongs to, which is what matters when you are ordering. If you know your engine is an FD620D, this is the gasket.\u003c\/p\u003e\n\n\u003ch2\u003eWhen to replace it\u003c\/h2\u003e\n\u003cp\u003eValve cover gaskets are a routine casualty of any valve clearance adjustment — and on these engines valve clearance is a scheduled maintenance item, so the gasket gets disturbed on a known interval. Have the gaskets on the shelf before you start the job rather than discovering you need them with the covers off.\u003c\/p\u003e\n\u003cp\u003eOutside of scheduled work, the usual sign is oil weeping down the outside of the head and collecting on the engine or in the machine bay. On a truckmount that oil then attracts the fine dust and fibre that a cleaning van is full of, which is why an FD620D with a weeping cover looks worse than the leak actually is.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eDo not re-use a valve cover gasket. It costs very little and the cover has to come off again if it weeps.\u003c\/p\u003e\n\u003cp\u003eClean both faces before fitting and check the cover itself for distortion — over-tightening the cover fasteners on a previous service is the usual cause of a cover that will not seal on a new gasket.\u003c\/p\u003e\n\u003cp\u003eFollow Kawasaki's torque figure for the cover fasteners. These are light fastenings into an alloy head and they do not want to be nipped up by feel.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eTwo per engine.\u003c\/p\u003e\n\u003ch3\u003eWill it fit an FD620D in something other than a truckmount?\u003c\/h3\u003e\n\u003cp\u003eIt is a gasket for that engine, so in principle yes. Check the engine model and specification number on the engine's data label before ordering.\u003c\/p\u003e\n\u003ch3\u003eIs this a genuine Kawasaki part?\u003c\/h3\u003e\n\u003cp\u003eIt is supplied under HydraMaster part number 000-057-023. We have not verified whether it carries a Kawasaki part number as well. Ask us if OEM branding matters for your warranty situation.\u003c\/p\u003e\n\u003ch3\u003eDo I need sealant as well?\u003c\/h3\u003e\n\u003cp\u003eFollow the engine manufacturer's instruction for your engine — some applications call for sealant at the cover corners and some do not. Do not apply sealant on assumption.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eServicing an FD620D? Tell us what you are doing and we will check what else in the service kit you are likely to want at the same time.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eMore \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e parts and equipment, and the full range in \u003ca href=\"\/collections\/parts-maintenance\"\u003eParts \u0026amp; Maintenance\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gasket-p-220-exhaust-man\"\u003eBriggs \u0026amp; Stratton Exhaust Manifold Gasket P-220 (057-016)\u003c\/a\u003e — Briggs \u0026amp; Stratton exhaust manifold gasket\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gasket-exhaust-donut-1-5\"\u003eGasket Exhaust Donut 1.5\" (057-177)\u003c\/a\u003e — exhaust donut gasket, 1.5 inch\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672577543,"sku":"057-023","price":16.47,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Kawasaki-FD620D-Valve-Cover-Gasket.jpg?v=1780550273"},{"product_id":"gasket-recovery-tank-all-units","title":"Gasket Recovery Tank - All Units","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eRecovery tank lid gasket for HydraMaster truckmounts. HydraMaster part number 000-057-043, listed as \u003cem\u003eGasket, Recovery Tank\u003c\/em\u003e and, in HydraMaster's own suggested spares schedule, as the \u003cem\u003ewaste tank gasket kit\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is supplied as a length. In most cases it will be longer than you need — cut it to suit your machine.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eThis is the closest thing HydraMaster has to a universal part. Their suggested spares schedule lists it against every machine in the range:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoxxer 421 and Boxxer 427\u003c\/li\u003e\n\u003cli\u003eCDS 4.6, CDS 4.7 and CDS 4.8\u003c\/li\u003e\n\u003cli\u003eCTS330 and CTS450\u003c\/li\u003e\n\u003cli\u003eMAXX 450D \/ 470D\u003c\/li\u003e\n\u003cli\u003eSpitFire 3.2 and SpitFire 4.0\u003c\/li\u003e\n\u003cli\u003eCrossfire 4.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e it suits HydraMaster machines that do not have a MaxxAir tank. If your machine has the MaxxAir arrangement, ask us before ordering.\u003c\/p\u003e\n\n\u003ch2\u003eWhich tank do you have?\u003c\/h2\u003e\n\u003cp\u003eHydraMaster changed the waste tank sealing arrangement between generations, and the two arrangements do not take the same gasket.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOlder tanks\u003c\/strong\u003e — the gasket is pushed onto the edge of the tank itself. That is this part, 057-043.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNewer tanks\u003c\/strong\u003e — a flat gasket sits against the underside of the lid. Those take the pre-cut lid gaskets or \u003ca href=\"\/products\/waste-tank-gasket-strip-25mm-5mm-13-7m-roll\"\u003eWaste Tank Gasket Strip 25mm × 5mm (SS-41-018)\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck the tank before you order. If the seal pushes onto the tank edge, this is the part. If it sits flat on the lid, it is not.\u003c\/p\u003e\n\u003ch2\u003eWhy the recovery tank seal matters\u003c\/h2\u003e\n\u003cp\u003eEverything the machine recovers depends on the tank holding vacuum. A lid gasket that has gone hard, taken a permanent set, or lifted at a corner is a leak in the largest, lowest-pressure part of the vacuum path — and it costs you lift at the wand on every job.\u003c\/p\u003e\n\u003cp\u003eIt is also the leak operators most often miss, because the machine sounds and looks normal. The vacuum gauge tells the story: if lift is down and the gauge is not climbing, air is getting in somewhere it should not, and the lid is the first place to check.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eClean the channel properly. Old adhesive, dried slurry and fibre under a new gasket will hold it off the sealing face and you will not get the seal back.\u003c\/p\u003e\n\u003cp\u003eCut it slightly long rather than short, and butt the join on a straight run rather than at a corner. A join at a corner is where the seal will fail first.\u003c\/p\u003e\n\u003cp\u003eFit it relaxed. Stretching the gasket into place makes it look right on the bench and pull back into a gap after a few heat cycles.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow much do I get?\u003c\/h3\u003e\n\u003cp\u003eIt is supplied as a length intended to be cut to fit. It is normally longer than a single machine needs.\u003c\/p\u003e\n\u003ch3\u003eWill it fit my machine?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster list it against every truckmount in the range except machines with the MaxxAir tank. If yours has a MaxxAir tank, ask us first.\u003c\/p\u003e\n\u003ch3\u003eDo I need adhesive?\u003c\/h3\u003e\n\u003cp\u003eFollow the arrangement on your machine — check what was fitted before you strip it. Do not glue a gasket into a channel designed to hold it mechanically.\u003c\/p\u003e\n\u003ch3\u003eHow do I know the seal has gone?\u003c\/h3\u003e\n\u003cp\u003eVacuum lift down at the wand with no rise on the vacuum gauge, or a gasket you can compress with a thumbnail and it stays compressed.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eChasing a vacuum loss? Tell us the machine and the symptoms and we will help you work through the likely causes before you start buying parts.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eMore \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e parts and equipment, and the full range in \u003ca href=\"\/collections\/parts-maintenance\"\u003eParts \u0026amp; Maintenance\u003c\/a\u003e.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672580679,"sku":"057-043","price":134.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Gasket-Recovery-Tank-All-Units.jpg?v=1780550273"},{"product_id":"gasket-rx-20-felt-hub","title":"HydraMaster RX 20 Felt Hub Gasket","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eFelt hub gasket for the HydraMaster RX-20 rotary extractor. HydraMaster part number 000-057-047, listed in the parts list as \u003cem\u003eGasket, Felt Hub\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe felt gasket seals the rotating hub. As the felt compresses and wears it starts to leak air, and the first symptom is usually lost vacuum at the heads rather than anything visible at the hub itself.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster part number: 000-057-047\u003c\/li\u003e\n\u003cli\u003eMaterial: felt\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne fitted per machine\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhich RX-20 does this fit?\u003c\/h2\u003e\n\u003cp\u003eHydraMaster has built the RX-20 since the 1980s and there have been many revisions. Carpet Cleaners Warehouse supplies the current machine, the \u003cstrong\u003eRX20 NEXTGEN, model 700-041-036\u003c\/strong\u003e (CE, 230 V, 50 Hz).\u003c\/p\u003e\n\u003cp\u003eThe current owner's manual, MAN-47328 Rev. B (March 2019), covers models 700-041-030, -031, -032, -035, \u003cstrong\u003e-036\u003c\/strong\u003e, -330, -331, -332, -333, -334 and -407. Earlier machines are covered by their own editions, going back to c. 1987.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, check the model number on your machine's data plate.\u003c\/strong\u003e If you are unsure, contact us with the number and we will confirm the correct part.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster parts lists in the 2011 owner’s manual (models 700-041-006 and -007), the 2014 edition (700-041-006, -007, -014, -316, -318 and -322) and the current 2019 NEXTGEN edition, MAN-47328 Rev. B.\u003c\/p\u003e\n\u003cp\u003eIn the NEXTGEN parts lists it is item 5 of vacuum head assembly 604-053-100, one per machine, listed as \u003cem\u003eGasket, Felt\u003c\/em\u003e in felt. That assembly is fitted to every NEXTGEN variant, including the CE 230 V 50 Hz machine, model 700-041-036, which is the one we supply.\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003eRX20 Felt Hub Gasket\u003c\/p\u003e\n\n\u003cp\u003eQuantity verified from the RX-20 owner’s manual MAN-47328 Rev. B (March 2019), Vacuum Head Assembly parts list, item 5.\u003c\/p\u003e\n\u003ch2\u003eRelated RX-20 parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gasket-rx20-vacuum-head\"\u003eRX20 Vacuum Head Gasket (057-048)\u003c\/a\u003e — 5 per machine\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/rx20-head-4inch-shoe-one-piece\"\u003eRX20 4in Cast Shoe (064-030)\u003c\/a\u003e — 5 per machine\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hose-vac-hub-skid-rx-20\"\u003eRX20 1in Vacuum Hose (068-174)\u003c\/a\u003e — 5 per machine\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/nipple-1-8-x-4-s-steel-rx20\"\u003eRX20 Stainless Nipple 1\/8in x 4in (052-515)\u003c\/a\u003e — 3 per machine\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/switch-micro-rx20\"\u003eRX20 Micro Switch (157-032)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eOne per machine. Unlike the vacuum head gasket, which takes five, the hub seal is a single item.\u003c\/p\u003e\n\u003ch3\u003eHow do I know it has gone?\u003c\/h3\u003e\n\u003cp\u003eLost vacuum at the heads with nothing visible at the hub. The felt compresses and wears gradually, so it leaks well before it looks worn out.\u003c\/p\u003e\n\u003ch3\u003eShould I replace it when I service the hub?\u003c\/h3\u003e\n\u003cp\u003eYes. It is a low-cost item and the hub has to come apart to reach it, so replacing it while you are in there saves a second strip-down.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/RX-20_20190301_Manual.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOwner’s Manual — MAN-47328 Rev. B, March 2019 (PDF, 15 MB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis manual covers models 700-041-030, -031, -032, -035, -036, -330, -331, -332, -333, -334 and -407. If your machine is older, contact us with the model number from the data plate and we will send the edition that matches it.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672581191,"sku":"057-047","price":16.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/HydraMaster-RX-20-Felt-Hub-Gasket.jpg?v=1780550274"},{"product_id":"gasket-rx20-vacuum-head","title":"HydraMaster RX20 Vacuum Head Gasket","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eVacuum head gasket for the HydraMaster RX-20 rotary extractor. HydraMaster part number 000-057-048, listed as \u003cem\u003eGasket, Vacuum Head\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe gasket seals the vacuum head to the shoe. When it hardens or splits, airflow is lost at the head and the carpet comes up wetter without any obvious symptom at the machine.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster part number: 000-057-048\u003c\/li\u003e\n\u003cli\u003eMaterial: EPDM, 60 durometer, cotton-cloth inserted\u003c\/li\u003e\n\u003cli\u003eOne per vacuum shoe assembly — \u003cstrong\u003efive per machine\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhich RX-20 does this fit?\u003c\/h2\u003e\n\u003cp\u003eHydraMaster has built the RX-20 since the 1980s and there have been many revisions. Carpet Cleaners Warehouse supplies the current machine, the \u003cstrong\u003eRX20 NEXTGEN, model 700-041-036\u003c\/strong\u003e (CE, 230 V, 50 Hz).\u003c\/p\u003e\n\u003cp\u003eThe current owner's manual, MAN-47328 Rev. B (March 2019), covers models 700-041-030, -031, -032, -035, \u003cstrong\u003e-036\u003c\/strong\u003e, -330, -331, -332, -333, -334 and -407. Earlier machines are covered by their own editions, going back to c. 1987.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering, check the model number on your machine's data plate.\u003c\/strong\u003e If you are unsure, contact us with the number and we will confirm the correct part.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster parts lists in the 2011 owner’s manual (models 700-041-006 and -007), the 2014 edition (700-041-006, -007, -014, -316, -318 and -322) and the current 2019 NEXTGEN edition, MAN-47328 Rev. B.\u003c\/p\u003e\n\u003cp\u003eIn the NEXTGEN parts lists it is item 1 of vacuum shoe and skid assembly 000-064-012. Vacuum head assembly 604-053-100 carries \u003cstrong\u003efive of those shoe assemblies\u003c\/strong\u003e, so a complete re-gasket takes five gaskets, not one. The same vacuum head is fitted to every NEXTGEN variant, including the CE 230 V 50 Hz machine, model 700-041-036, which is the one we supply.\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eQuantities verified from the RX-20 owner’s manual MAN-47328 Rev. B (March 2019), Vacuum Head Assembly and Vacuum Shoe \u0026amp; Skid Assembly parts lists.\u003c\/p\u003e\n\u003ch2\u003eRelated RX-20 parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/rx20-head-4inch-shoe-one-piece\"\u003eRX20 4in Cast Shoe (064-030)\u003c\/a\u003e — 5 per machine\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hose-vac-hub-skid-rx-20\"\u003eRX20 1in Vacuum Hose (068-174)\u003c\/a\u003e — 5 per machine\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/nipple-1-8-x-4-s-steel-rx20\"\u003eRX20 Stainless Nipple 1\/8in x 4in (052-515)\u003c\/a\u003e — 3 per machine\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gasket-rx-20-felt-hub\"\u003eRX20 Felt Hub Gasket (057-047)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/switch-micro-rx20\"\u003eRX20 Micro Switch (157-032)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eFive. One per vacuum shoe and skid assembly, and the vacuum head carries five of those assemblies. Ordering one is the most common mistake on this part.\u003c\/p\u003e\n\u003ch3\u003eHow do I know it has gone?\u003c\/h3\u003e\n\u003cp\u003eThe carpet comes up wetter with nothing obviously wrong at the machine. Airflow is lost at the head rather than at the hose.\u003c\/p\u003e\n\u003ch3\u003eWhat is it made from?\u003c\/h3\u003e\n\u003cp\u003eEPDM, 60 durometer, cotton-cloth inserted — per the HydraMaster parts list.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/RX-20_20190301_Manual.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eOwner’s Manual — MAN-47328 Rev. B, March 2019 (PDF, 15 MB)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis manual covers models 700-041-030, -031, -032, -035, -036, -330, -331, -332, -333, -334 and -407. If your machine is older, contact us with the model number from the data plate and we will send the edition that matches it.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672581767,"sku":"057-048","price":18.22,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/HydraMaster-RX20-Vacuum-Head-Gasket.jpg?v=1780550274"},{"product_id":"gasket-4-bolt-ext-div-flange","title":"Gasket 4 Bolt Exhaust Diverter Flange","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eFour-bolt flange gasket for the exhaust diverter valve on HydraMaster truckmounts. HydraMaster part number 000-057-146, listed variously as \u003cem\u003eGasket, Four Hole Exhaust Diverter\u003c\/em\u003e, \u003cem\u003eGasket, Four Hole Exhaust\u003c\/em\u003e and \u003cem\u003eGasket, four-bolt flange — for exhaust diverter\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe exhaust diverter is what sends engine exhaust either through the heat exchanger or out to atmosphere. Its flange joints run hot, cycle constantly, and are the joints most likely to leak on a truckmount.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits and how many\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts lists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoxxer 421\u003c\/strong\u003e — 3 fitted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoxxer 427\u003c\/strong\u003e — 3 to 4 fitted depending on the assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoxxer 423S\u003c\/strong\u003e — 2 to 3 fitted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoxxer XL\u003c\/strong\u003e — 1 fitted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTitan 425\u003c\/strong\u003e — 2 to 3 fitted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMAXX 450D \/ 470D \/ Diesel\u003c\/strong\u003e — 3 fitted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCM402\u003c\/strong\u003e — 1 fitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCount the flanges on your machine before you order.\u003c\/strong\u003e The quantity varies between models and between assemblies within a model, and there is no worse moment to discover you are one gasket short than with the exhaust apart.\u003c\/p\u003e\n\n\u003ch2\u003eRelated exhaust parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gasket-exhaust-donut-1-5\"\u003eGasket Exhaust Donut 1.5\" (057-177)\u003c\/a\u003e — the slip-joint gasket used elsewhere in the same exhaust system\u003c\/li\u003e\n\u003cli\u003eHydraMaster also list diverter kit 078-808 and diverter nut, bolt and gasket kit 078-331. Neither is currently a stocked CCW line — ask us if you need one.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eReplace every gasket you disturb, not just the one that was leaking. They are inexpensive, and a used exhaust gasket has already taken its set to the old joint.\u003c\/p\u003e\n\u003cp\u003eCheck the flange faces for distortion while you have them apart. A leaking diverter flange is very often a warped face rather than a failed gasket, and a new gasket will not fix a warped face.\u003c\/p\u003e\n\u003cp\u003eExhaust fasteners loosen with heat cycling. Check them again after the first few hours of running.\u003c\/p\u003e\n\u003cp\u003eAn exhaust leak inside a van is a safety matter, not just a performance one. Do not run the machine with a known leak.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eBetween one and four depending on the machine and which assembly you are working on. See the list above, and count the flanges before you order.\u003c\/p\u003e\n\u003ch3\u003eIs this the same as the donut gasket?\u003c\/h3\u003e\n\u003cp\u003eNo. The donut (057-177) seals a slip joint. This one seals a four-bolt flange.\u003c\/p\u003e\n\u003ch3\u003eCan I re-use one that looks intact?\u003c\/h3\u003e\n\u003cp\u003eNo. It has already conformed to the old joint under heat.\u003c\/p\u003e\n\u003ch3\u003eWhat material is it?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not state the material in the parts lists we hold. We are not going to guess. Ask us if the specification matters.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eWorking on a diverter? Tell us the machine model and serial number and we will check the assembly drawing for the exact gasket count, fasteners and any other parts you should replace at the same time.\u003c\/p\u003e\n\u003ch2\u003eTITAN 425 fitment\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts listing for the \u003cstrong\u003eHydraMaster TITAN 425\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExhaust Diverted Assembly (610-013-005) — \u003cstrong\u003e2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eExhaust Diverter Valve Assembly (610-013-003) — \u003cstrong\u003e3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFive are used on a TITAN 425 in total — two in the exhaust diverted assembly and three in the exhaust diverter valve assembly.\u003c\/p\u003e\n\u003cp\u003eVerified from the HydraMaster \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Titan_425_Parts_Listing_HQ_SEARCHABLE_LANDSCAPE_FINAL.pdf?v=1787560109\"\u003eTITAN 425 parts listing\u003c\/a\u003e, MAN-47791 Rev A.\u003c\/p\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672595911,"sku":"057-146","price":36.93,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Gasket-4-Bolt-Exhaust-Diverter-Flange.jpg?v=1780550275"},{"product_id":"gasket-exhaust-donut-1-5","title":"Gasket Exhaust Donut 1.5\"","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eExhaust donut gasket, 1½ inch, listed by HydraMaster as \u003cem\u003eGasket, Exhaust Donut 1.50\"\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt seals the exhaust joints in the diverter and muffler run. Exhaust gaskets are a consumable — heat cycling hardens them and they leak. On a truckmount an exhaust leak is both a carbon monoxide risk in the vehicle and a loss of heat to the exchanger.\u003c\/p\u003e\n\u003ch2\u003eWhere it is fitted\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eExhaust assembly — \u003cstrong\u003e2 per machine\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eUsed with the cast exhaust diverter valve 000-169-045 and the four-hole diverter gasket 000-057-146\u003c\/li\u003e\n\u003cli\u003eHydraMaster lists it as a suggested spare across four of its truckmount models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFitting note\u003c\/h2\u003e\n\u003cp\u003eReplace both, not one. A new gasket beside a hardened one loads the joint unevenly and the new one fails early.\u003c\/p\u003e\n\u003ch2\u003eVerified fitment — current machines\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/hydramaster-boxxer-318hp-1500psi-in-the-boxgloves-off-pricing\"\u003eBoxxer 318HP\u003c\/a\u003e — Exhaust Assembly (Figure 9-26), \u003cstrong\u003e1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCCW's own records list two per machine across earlier models. The Boxxer 318HP exhaust assembly shows one. If you are replacing both sides of a joint, confirm the count for your machine before ordering.\u003c\/p\u003e\n\u003cp\u003eVerified from the HydraMaster parts books: Boxxer 318HP MAN-46586 Rev C and TMTG4000 MAN-47717 Rev B.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/gasket-4-bolt-ext-div-flange\"\u003eGasket 4 Bolt Exhaust Diverter Flange (057-146)\u003c\/a\u003e — the four-hole diverter gasket\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gasket-p-220-exhaust-man\"\u003eBriggs \u0026amp; Stratton Exhaust Manifold Gasket P-220 (057-016)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow often should exhaust gaskets be replaced?\u003c\/h3\u003e\n\u003cp\u003eWhenever the joint is opened. Heat cycling work-hardens them and a reused gasket rarely seals a second time.\u003c\/p\u003e\n\u003ch3\u003eWhy does an exhaust leak matter more on a truckmount?\u003c\/h3\u003e\n\u003cp\u003eTwo reasons. It is a carbon monoxide risk inside the vehicle, and it loses heat that should be going to the exchanger.\u003c\/p\u003e\n\u003ch3\u003eCan I fit one new gasket and leave the other?\u003c\/h3\u003e\n\u003cp\u003eNot advisable. A new gasket beside a hardened one loads the joint unevenly and the new one fails early.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eSend us your machine model and serial number and we will confirm the correct gaskets and quantities before you order.\u003c\/p\u003e\u003ch2\u003eIdentifying the right part\u003c\/h2\u003e\n\u003cp\u003eHydraMaster truckmounts share many components across models and across production years. Part numbers in the CCW catalogue are the HydraMaster part number with the \u003ccode\u003e000-\u003c\/code\u003e prefix removed — this item is HydraMaster P\/N \u003cstrong\u003e000-057-177\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIf you are ordering for an existing machine, check the model and serial number on the data plate and send them to us. We will confirm the part against the parts list for your machine before you order.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster \u003cstrong\u003eBoxxer 421\u003c\/strong\u003e machine assemblies and parts lists (drawing set D-5057 \/ D-6861). Fitment to other HydraMaster models has not been verified from a parts list — ask us if you are ordering for a different machine.\u003c\/p\u003e\u003chr\u003e\u003cdiv class=\"tabbable\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv class=\"tab-pane active\" id=\"description\"\u003e\n\n\u003cp\u003e1½\" Donut Exhaust Gasket\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672599111,"sku":"057-177","price":26.88,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Gasket-Exhaust-Donut-1_5.jpg?v=1780550275"},{"product_id":"hydramaster-dm2-3-optional-handle-kit","title":"HydraMaster DM2\/3 Optional Handle Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eOptional handle accessory assembly for the HydraMaster DriMaster upholstery tools. HydraMaster part number 000-061-144.\u003c\/p\u003e\n\u003cp\u003eIt adds a second grip point to the tool, which changes how the tool can be worked — particularly on stackable chairs, theatre seating and any job where the tool is being driven from an awkward angle for long periods.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eDriMaster II\u003c\/strong\u003e upholstery tool\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eDriMaster III\u003c\/strong\u003e upholstery tool\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DriMaster III HiFlo tool manual describes it directly: the tool can be equipped with an optional accessory handle. It appears in both the DM2 and DM3 manuals as the \u003cem\u003eHandle Accessory Assembly\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIt is not listed for the DriMaster I.\u003c\/strong\u003e The DM1 parts breakdown does not include it. If you have a DM1, ask us before ordering.\u003c\/p\u003e\n\n\u003ch2\u003eWhy fit one\u003c\/h2\u003e\n\u003cp\u003eUpholstery work is the most physically awkward cleaning most operators do. The tool is small, the work is at odd heights, and the operator is often bent over or reaching. A single grip point means the wrist and forearm take all of the load and all of the control.\u003c\/p\u003e\n\u003cp\u003eA second handle lets you brace the tool with one hand and drive it with the other. On a long run of theatre seating or a stack of function-centre chairs, that is the difference between finishing the job comfortably and finishing it sore.\u003c\/p\u003e\n\u003cp\u003eIt also improves control on vertical faces — chair backs and panel work — where a one-handed tool tends to skip rather than track.\u003c\/p\u003e\n\n\u003ch2\u003eFitting\u003c\/h2\u003e\n\u003cp\u003eIt is an accessory assembly designed to fit the existing tool, so no modification should be needed. Follow the handle accessory assembly parts list in your DriMaster manual for the fastener arrangement.\u003c\/p\u003e\n\u003cp\u003eSet the handle position before you commit to it — the right angle depends on your height and how you naturally hold the tool, not on where it looks tidiest on the bench.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit my DriMaster I?\u003c\/h3\u003e\n\u003cp\u003eNot according to the DM1 parts breakdown, which does not list it. Ask us with your tool details before ordering.\u003c\/p\u003e\n\u003ch3\u003eDoes it change the tool's cleaning performance?\u003c\/h3\u003e\n\u003cp\u003eNo. It changes how the tool is held, not how it cleans. What it can improve is consistency, because a tool you can control properly gets worked evenly.\u003c\/p\u003e\n\u003ch3\u003eCan it be removed again?\u003c\/h3\u003e\n\u003cp\u003eYes — it is an accessory assembly, not a permanent modification.\u003c\/p\u003e\n\u003ch3\u003eIs it supplied with fasteners?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster lists it as a handle accessory assembly. We have not verified the exact contents against a packing list. Ask us if you need to know before ordering.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eDoing volume upholstery work? Tell us which DriMaster you run and we will confirm the handle suits it before you order.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eSee the full \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e range.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/dm3-hiflow-drimaster-upholstery-tool\"\u003eHydraMaster DriMaster 3 Upholstery Cleaning Tool (163-220)\u003c\/a\u003e — DriMaster 3 upholstery cleaning tool\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/valve-manual-ball-drimaster\"\u003eDrimaster Manual Ball Valve (169-014)\u003c\/a\u003e — DriMaster manual ball valve\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672603335,"sku":"061-144","price":139.54,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/HydraMaster-DM23-Optional-Handle-Kit.jpg?v=1780550275"},{"product_id":"impeller-replacement-ext-apo","title":"Impeller Replacement EXT APO","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eReplacement impeller for the external automatic pump-out (APO) on HydraMaster truckmounts. HydraMaster part number 000-073-011, listed as \u003cem\u003eImpeller, Replacement — for any machine with external APO\u003c\/em\u003e and, in later manuals, \u003cem\u003eImpeller, Replacement for Posi-Flow and Dura-Flow\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe automatic pump-out empties the recovery tank while you keep working. When its impeller wears, the pump-out slows, then stops keeping up, and the tank fills — usually on the job where you can least afford it.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eHydraMaster's suggested spares schedule lists this impeller against \u003cstrong\u003eevery machine in the range fitted with an external APO\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoxxer 421 and Boxxer 427\u003c\/li\u003e\n\u003cli\u003eCDS 4.6 and CDS 4.8\u003c\/li\u003e\n\u003cli\u003eCTS330 and CTS450\u003c\/li\u003e\n\u003cli\u003eMAXX 450D \/ 470D\u003c\/li\u003e\n\u003cli\u003eSpitFire 3.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is also listed for the \u003cstrong\u003ePosi-Flow\u003c\/strong\u003e and \u003cstrong\u003eDura-Flow\u003c\/strong\u003e APO assemblies, including on the Boxxer 323HP.\u003c\/p\u003e\n\u003cp\u003eThe qualifier that matters is \u003cem\u003eexternal\u003c\/em\u003e APO. If your machine has an internal pump-out arrangement, this is not the part.\u003c\/p\u003e\n\n\u003ch2\u003eWhy impellers wear\u003c\/h2\u003e\n\u003cp\u003eAn APO impeller lives in dirty water carrying grit, fibre and hair. It wears from abrasion at the vane tips, and it is damaged by running dry.\u003c\/p\u003e\n\u003cp\u003eThe failure is gradual, which is what makes it easy to miss: the pump-out keeps working but moves less each month. By the time an operator notices the tank filling, the impeller is usually well past serviceable. If pump-out has been \"getting a bit slow\" for a while, the impeller is the first thing to look at.\u003c\/p\u003e\n\u003cp\u003eFibre wrapped around the impeller hub is the other common finding, and it does not always show as a total blockage — just as reduced flow and a motor working harder than it should.\u003c\/p\u003e\n\n\u003ch2\u003eMaintenance\u003c\/h2\u003e\n\u003cp\u003eInspect the impeller when you service the APO rather than waiting for a symptom. Look for rounded or chipped vane tips, scoring on the faces, and anything wrapped around the hub.\u003c\/p\u003e\n\u003cp\u003eAvoid running the APO dry. It is the fastest way to destroy an impeller and it happens most often when a float switch has failed rather than through operator error — so check the float switch is working while you are in there.\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/switch-ss-float-recovery-tank\"\u003eHydraMaster Recovery Tank Float Switch (157-0801)\u003c\/a\u003e — a failed float switch is the usual reason an APO runs dry\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/kit-s-s-float-splash-guard\"\u003eFloat Splash Guard Kit (078-357)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit my machine?\u003c\/h3\u003e\n\u003cp\u003eIf your machine has an external APO, HydraMaster list this impeller for it. Confirm your machine has an \u003cem\u003eexternal\u003c\/em\u003e pump-out, not an internal arrangement.\u003c\/p\u003e\n\u003ch3\u003eDoes it fit Posi-Flow and Dura-Flow?\u003c\/h3\u003e\n\u003cp\u003eYes — both are named in HydraMaster's parts lists for this impeller.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with seals or a housing?\u003c\/h3\u003e\n\u003cp\u003eIt is listed as the impeller alone. If the shaft seal is weeping, that is a separate part and worth doing at the same time — ask us.\u003c\/p\u003e\n\u003ch3\u003eHow often should it be replaced?\u003c\/h3\u003e\n\u003cp\u003eOn condition. HydraMaster treat it as a suggested spare rather than a fixed-interval item. Operators doing heavy restoration work replace them far more often than those doing domestic maintenance cleaning.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003ePump-out slowing down? Tell us the machine model and what you are seeing and we will help you work out whether it is the impeller, the float switch or a restriction before you order.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eMore \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e parts and equipment, and the full range in \u003ca href=\"\/collections\/parts-maintenance\"\u003eParts \u0026amp; Maintenance\u003c\/a\u003e.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672604743,"sku":"073-011","price":203.76,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Impeller-Replacement-EXT-APO.jpg?v=1780550278"},{"product_id":"gauge-hi-psi-0-1000","title":"Water Pressure Gauge - 1000 psi","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eSolution pressure gauge, 0–1000 psi. HydraMaster part number 000-074-003, listed as \u003cem\u003eGauge, High PSI (0-1000)\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThis is the gauge that tells you what the machine is actually doing at the pump, as distinct from what you assume it is doing. On a truckmount it is a diagnostic instrument first and a display second.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts lists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCDS 4.2 \/ 4.7\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCDS 4.8\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 4.0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCrossfire 4.2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydraMaster's suggested spares schedule also lists a 0–1500 psi gauge (074-007) for the Boxxer 421, Boxxer 427, CDS 4.6\/4.8, MAXX and SpitFire 3.2, and a 0–3000 psi gauge (074-167) for the Boxxer 318HP and 323HP.\u003c\/p\u003e\n\n\u003ch2\u003eImportant — match the range to the machine\u003c\/h2\u003e\n\u003cp\u003eThree pressure gauges appear across the HydraMaster range and they are not interchangeable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e074-003\u003c\/strong\u003e — 0–1000 psi (this gauge)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e074-007\u003c\/strong\u003e — 0–1500 psi (not currently a stocked CCW line)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/gauge-pressure-2-5-0-3000-psi-bx318hp-323\"\u003e\u003cstrong\u003e074-167\u003c\/strong\u003e — 0–3000 psi, 2.5 inch dial\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFitting a 0–1000 psi gauge to a machine that runs beyond 1000 psi will destroy the gauge and leave you with no reading at all. Fitting an over-range gauge to a low-pressure machine gives you a needle that barely moves and a reading you cannot use to diagnose anything. \u003cstrong\u003eCheck the pressure your machine actually runs at before you order.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eReading it properly\u003c\/h2\u003e\n\u003cp\u003eA gauge is most useful when you know what normal looks like on your machine. Note the reading at rest, at trigger, and with the by-pass open, when the machine is known good — that gives you a baseline to compare against later.\u003c\/p\u003e\n\u003cp\u003ePressure that reads correctly at rest and falls away under trigger points at the pump, the by-pass valve seals or a restriction, not at the gauge. Pressure that will not hold at a set point usually means worn by-pass seals.\u003c\/p\u003e\n\u003cp\u003eA gauge whose needle never returns to zero, or that sits visibly off zero at rest, is telling you it has been over-pressured or shocked. Replace it — a gauge you do not trust is worse than no gauge, because it will send you looking in the wrong place.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat thread does it have?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not state the connection size in the parts lists we hold. Check what is fitted to your machine, or send us a photo and we will confirm before you order.\u003c\/p\u003e\n\u003ch3\u003eIs it glycerine filled?\u003c\/h3\u003e\n\u003cp\u003eNot stated in the documentation we hold. Ask us if damping matters for your installation — a pulsing needle on a plunger-pump machine is common and a filled gauge is the usual answer.\u003c\/p\u003e\n\u003ch3\u003eMy gauge reads high but the machine cleans poorly. What now?\u003c\/h3\u003e\n\u003cp\u003eHigh pressure with poor flow usually means a restriction downstream — the ¼ inch Y strainer screen, the orifice, or the jets. Start with the strainer.\u003c\/p\u003e\n\u003ch3\u003eCan I fit a 0–1500 psi gauge instead?\u003c\/h3\u003e\n\u003cp\u003eOnly if your machine is specified for one. Over-range gauges cost you diagnostic resolution across the range you actually use.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot sure which gauge your machine takes? Send us the model and serial number and we will check the parts list before you order.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672605255,"sku":"074-003","price":187.01,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Water-Pressure-Gauge-1000-psi.jpg?v=1780550278"},{"product_id":"meter-chemical-flow-knob","title":"Meter Chemical Flow (Knob)","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eChemical flow meter with adjusting knob. HydraMaster part number 000-074-013, listed as \u003cem\u003eMeter, Chemical Flow\u003c\/em\u003e. It is the same part as Prochem PP18-808522.\u003c\/p\u003e\n\u003cp\u003eThe flow meter sets and shows the rate at which chemical is metered into the solution stream. It is what stands between a repeatable dilution and a guess.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts lists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 3.2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 4.0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydraMaster's suggested spares schedule lists it against the SpitFire 3.2. It also appears on Prochem equipment under part number PP18-808522.\u003c\/p\u003e\n\n\u003ch2\u003eRepair before replacement\u003c\/h2\u003e\n\u003cp\u003eA flow meter that is sticking, weeping or reading erratically does not always need replacing. HydraMaster list a repair kit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kit-chem-flow-meter-repair\"\u003e\u003cstrong\u003e078-015\u003c\/strong\u003e — Chemical Flowmeter Repair Kit\u003c\/a\u003e, which covers 074-013, 074-020 and Prochem PP18-808522\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTry the repair kit first. The failure is usually seals and the float sticking in a fouled tube, not the meter body.\u003c\/p\u003e\n\n\u003ch2\u003eOperating advice\u003c\/h2\u003e\n\u003cp\u003eFlush the chemical system with clean water at the end of the day, particularly after anything alkaline or anything that dries hard. Most flow meter failures are deposits in the tube rather than mechanical wear.\u003c\/p\u003e\n\u003cp\u003eRead the float at the same point each time — normally the top of the float unless the meter states otherwise. Half the inconsistency operators blame on the meter is reading it differently on different days.\u003c\/p\u003e\n\u003cp\u003eA float that jumps or hangs at one point in its travel is telling you the tube is fouled or scored at that point. Clean it before you condemn it.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit a machine other than a SpitFire?\u003c\/h3\u003e\n\u003cp\u003eIt is a standard HydraMaster metering component and is shared with Prochem equipment, so often yes. We have only verified it in the SpitFire parts lists. Send us your machine details and we will check.\u003c\/p\u003e\n\u003ch3\u003eIs it the same as the Prochem part?\u003c\/h3\u003e\n\u003cp\u003eYes — Prochem PP18-808522.\u003c\/p\u003e\n\u003ch3\u003eWhat flow range does it cover?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not state the calibrated range in the parts lists we hold, and we are not going to quote a figure we cannot verify. Ask us if you need the specification.\u003c\/p\u003e\n\u003ch3\u003eShould I buy the repair kit or the meter?\u003c\/h3\u003e\n\u003cp\u003eTry the kit first unless the body is cracked or the tube is damaged. It is the cheaper answer and it is usually the right one.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eChemical dosing gone inconsistent? Tell us what you are seeing and we will help you decide between a clean, a repair kit and a new meter.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672605703,"sku":"074-013","price":404.66,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Meter-Chemical-Flow-Knob.jpg?v=1780550279"},{"product_id":"kit-chem-flow-meter-repair","title":"Chemical Flowmeter Repair Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eRepair kit for the HydraMaster chemical flow meter. HydraMaster part number 000-078-015, listed as \u003cem\u003eKit, Chemical Flowmeter Repair\u003c\/em\u003e and, in some manuals, simply \u003cem\u003eKit, Flow Meter\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt covers flow meters \u003cstrong\u003e074-013\u003c\/strong\u003e, \u003cstrong\u003e074-020\u003c\/strong\u003e and Prochem \u003cstrong\u003ePP18-808522\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts lists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCDS 4.2 \/ 4.7\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCDS 4.8\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 4.0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCrossfire 4.2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBecause the kit is specified by meter rather than by machine, it suits any machine running one of the three meters listed above.\u003c\/p\u003e\n\n\u003ch2\u003eRepair before replacement\u003c\/h2\u003e\n\u003cp\u003eMost chemical flow meter faults are seals and deposits, not mechanical failure. Before you replace a meter, work through this:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat sticking or hanging at one point\u003c\/strong\u003e — the tube is fouled or scored at that point. Clean it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeeping at the fittings\u003c\/strong\u003e — seals. This kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReading inconsistently day to day\u003c\/strong\u003e — check you are reading the float at the same point each time before you blame the meter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCracked body or damaged tube\u003c\/strong\u003e — this is the one case where the kit will not help. Replace the meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe relevant meter is \u003ca href=\"\/products\/meter-chemical-flow-knob\"\u003eMeter Chemical Flow (Knob) — 074-013\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eNote the orientation of every seal as it comes out, and take a photo before you strip it. Flow meters go back together in a way that looks right and is wrong.\u003c\/p\u003e\n\u003cp\u003eClean the tube properly while it is apart — that is half the reason the meter stopped behaving. Do not use anything abrasive on the tube; scoring it will cause the exact fault you are trying to fix.\u003c\/p\u003e\n\u003cp\u003eFlush the chemical system through with clean water before you refit, so the new seals do not go straight back into the deposits that killed the old ones.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhich meters does it fit?\u003c\/h3\u003e\n\u003cp\u003e074-013, 074-020 and Prochem PP18-808522.\u003c\/p\u003e\n\u003ch3\u003eWhat is in the kit?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not itemise the kit contents in the documentation we hold, so we are not going to list contents we cannot verify. Ask us if you need to know exactly what is included before ordering.\u003c\/p\u003e\n\u003ch3\u003eWill a repair fix an erratic reading?\u003c\/h3\u003e\n\u003cp\u003eIf the cause is seals or deposits, yes. If the tube is scored or the body is cracked, no — replace the meter.\u003c\/p\u003e\n\u003ch3\u003eHow often should the meter be serviced?\u003c\/h3\u003e\n\u003cp\u003eOn condition. Machines running heavy alkaline chemistry, or that are not flushed at the end of the day, need it far more often.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eTell us the fault and the machine and we will help you decide between a clean, this kit, and a new meter before you spend anything.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672610951,"sku":"078-015","price":119.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Chemical-Flowmeter-Repair-Kit.jpg?v=1780550279"},{"product_id":"repair-o-ring-kit-hydramaster-solution-valve","title":"Repair O-Ring Kit - HydraMaster Solution Valve","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eO-ring repair kit for the HydraMaster stainless solution valve. HydraMaster part number 000-078-019, listed as \u003cem\u003eKit, HM Solution Valve Repair\u003c\/em\u003e and, in the tool manuals, as \u003cem\u003eKit, Wand Valve Plunger\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe solution valve is the trigger valve in the wand or tool. It is opened and closed thousands of times a day, under pressure, in hot water — and its seals are consumables, not failures.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eIt services the HydraMaster stainless solution valve (169-058), which is used across the range:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCDS 4.2 \/ 4.7\u003c\/strong\u003e — \u003cem\u003eKit, HM Solution Valve Repair\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCDS 4.8\u003c\/strong\u003e — \u003cem\u003eKit, Wand Valve Plunger\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eMAXX 450D \/ 470D\u003c\/strong\u003e — \u003cem\u003eKit, H\/M Solution Valve\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCrossfire 4.2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eRX-20\u003c\/strong\u003e — \u003cem\u003eSolution Valve Kit\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eDriMaster\u003c\/strong\u003e rotary and upholstery tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnywhere a HydraMaster stainless solution valve is fitted, this is the kit that services it.\u003c\/p\u003e\n\n\u003ch2\u003eWhen to fit it\u003c\/h2\u003e\n\u003cp\u003eThe classic symptom is a valve that \u003cstrong\u003edrips after the trigger is released\u003c\/strong\u003e. It is easy to live with and it should not be, because the drip is going onto the carpet you have just cleaned and into the pad you have just set.\u003c\/p\u003e\n\u003cp\u003eThe other symptoms are a trigger that has gone heavy or notchy, and weeping at the plunger where it enters the body. Both are the same cause: seals that have hardened or taken a set.\u003c\/p\u003e\n\u003cp\u003eSeals in this service harden from heat as much as they wear from movement. A valve on a machine running high solution temperature will need seals more often than the same valve on a cooler machine at the same hours.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eDepressurise the solution line before you start. This is a valve on a high-pressure circuit and it does not need to be explained twice.\u003c\/p\u003e\n\u003cp\u003eNote the order and orientation of the seals as they come out. Take a photo. They go back in a way that feels right and is not.\u003c\/p\u003e\n\u003cp\u003eCheck the plunger and the seat while it is apart. If the plunger is scored or the seat is pitted, new seals will drip again within weeks — at that point you are replacing the valve, not the seals.\u003c\/p\u003e\n\u003cp\u003eLubricate the new seals with something compatible with the chemistry the valve sees. Petroleum grease on the wrong elastomer will destroy a new kit faster than the job did.\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/stem-assembly-hydramaster-solution-valve\"\u003eHydraMaster Solution Valve Stem Assembly (600-012-002)\u003c\/a\u003e — the stem that runs in these seals\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/o-ring-set-hydramaster-pressure-regulator\"\u003eO-Ring Kit for HydraMaster 169-101 Pressure Regulator (097-028)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eMy valve drips. Is this the fix?\u003c\/h3\u003e\n\u003cp\u003eUsually. Check the plunger and seat for scoring first — if either is damaged, the valve needs replacing rather than resealing.\u003c\/p\u003e\n\u003ch3\u003eDoes it fit tools as well as wands?\u003c\/h3\u003e\n\u003cp\u003eYes. The same valve is used in the DriMaster rotary and upholstery tools and in the RX-20.\u003c\/p\u003e\n\u003ch3\u003eWhat is in the kit?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not itemise the contents in the documentation we hold, so we will not list contents we cannot verify. Ask us if you need to know before ordering.\u003c\/p\u003e\n\u003ch3\u003eHow many should I keep on the van?\u003c\/h3\u003e\n\u003cp\u003eAt least one. A dripping trigger valve is the sort of fault that turns a good job into a callback, and the repair takes minutes if the kit is on board.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot sure whether you need a seal kit or a new valve? Tell us what the valve is doing and we will help you work it out before you order.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eMore \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e parts and equipment, and the full range in \u003ca href=\"\/collections\/parts-maintenance\"\u003eParts \u0026amp; Maintenance\u003c\/a\u003e.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672614919,"sku":"078-019","price":25.49,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Repair-O-Ring-Kit-HydraMaster-Solution-Valve.jpg?v=1780550280"},{"product_id":"kit-valve-triplex-pump","title":"Triplex Pump Valve Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eValve kit for a triplex pump. HydraMaster part number 000-078-139, listed in CCW's records as \u003cem\u003eKit, Valve Triplex Pump\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe valves are what make a triplex plunger pump a pump. They open and close on every stroke, in water carrying whatever the machine has picked up, and they are a service item rather than a failure.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits — please check before ordering\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWe have not been able to confirm which pump this kit services from HydraMaster's published parts documentation.\u003c\/strong\u003e The part number does not appear in the machine parts lists or the suggested spares schedule we hold.\u003c\/p\u003e\n\u003cp\u003eTriplex is a pump layout, not a model — HydraMaster and its sister brands have used several triplex pumps across the range, and their valve kits are not interchangeable. Fitting the wrong kit means the pump comes apart twice.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSend us the make, model and, if you have it, the serial number from your pump before you order\u003c\/strong\u003e and we will confirm this is the right kit. We would rather check than have you fit the wrong one.\u003c\/p\u003e\n\u003cp\u003eWe have raised this with HydraMaster as part of an ongoing parts identification request. This page will be updated when we have their answer.\u003c\/p\u003e\n\n\u003ch2\u003eRelated pump service parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/kit-seal-triplex-pump\"\u003e\u003cstrong\u003e078-141\u003c\/strong\u003e — Triplex Pump Seal Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eValves and seals are usually done together. A pump that has run long enough to need one has generally earned the other, and doing both means one strip-down rather than two.\u003c\/p\u003e\n\n\u003ch2\u003eHow worn valves show themselves\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulsing or hammering\u003c\/strong\u003e that has worsened over time points at valves more often than seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSudden loss of pressure with no visible leak\u003c\/strong\u003e — check the valves first.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErratic pressure rather than a steady decline\u003c\/strong\u003e — a valve held open by debris, or a broken valve spring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeeping at the weep holes\u003c\/strong\u003e — that is seals, not valves.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eKeep the valve assemblies in order and the right way up as they come out. They are not all identical.\u003c\/p\u003e\n\u003cp\u003eInspect the seats. A pitted seat will not seal against a new valve, and no kit will fix that.\u003c\/p\u003e\n\u003cp\u003eCheck the inlet filtration before you close the pump up. Debris in a valve seat almost always arrived through a neglected strainer, and it will happen again.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit my pump?\u003c\/h3\u003e\n\u003cp\u003eAsk us first. We are not going to claim fitment we have not verified, and triplex valve kits are not interchangeable between pump makes.\u003c\/p\u003e\n\u003ch3\u003eWhat is in the kit?\u003c\/h3\u003e\n\u003cp\u003eNot itemised in the documentation we hold. Ask us before ordering if you need to know.\u003c\/p\u003e\n\u003ch3\u003eShould I do seals at the same time?\u003c\/h3\u003e\n\u003cp\u003eUsually yes — see 078-141.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eSend us the make and model of your pump, or a photo of the pump's data plate, and we will confirm the correct kit before you order.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672620295,"sku":"078-139","price":225.94,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Triplex-Pump-Valve-Kit.jpg?v=1780550281"},{"product_id":"kit-seal-triplex-pump","title":"Triplex Pump Seal Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eSeal kit for a triplex pump. HydraMaster part number 000-078-141, listed in CCW's records as \u003cem\u003eKit, Seal Triplex Pump\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe high-pressure seals run on the plungers and are the wear item that determines how long a triplex pump holds pressure. They are a service part, not a failure.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits — please check before ordering\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWe have not been able to confirm which pump this kit services from HydraMaster's published parts documentation.\u003c\/strong\u003e The part number does not appear in the machine parts lists or the suggested spares schedule we hold.\u003c\/p\u003e\n\u003cp\u003eTriplex is a pump layout, not a model. Several different triplex pumps appear across the HydraMaster and Prochem ranges, and their seal kits are not interchangeable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSend us the make, model and serial number from your pump before you order\u003c\/strong\u003e and we will confirm this is the right kit. We would rather check than have you strip a pump twice.\u003c\/p\u003e\n\u003cp\u003eWe have raised this with HydraMaster as part of an ongoing parts identification request. This page will be updated when we have their answer.\u003c\/p\u003e\n\n\u003ch2\u003eRelated pump service parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/kit-valve-triplex-pump\"\u003e\u003cstrong\u003e078-139\u003c\/strong\u003e — Triplex Pump Valve Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSeals and valves are usually done together — one strip-down rather than two.\u003c\/p\u003e\n\n\u003ch2\u003eWhen to fit seals\u003c\/h2\u003e\n\u003cp\u003eThe symptoms are all pressure symptoms: pressure that will not reach the set point, pressure that holds at rest and falls away under trigger, or a pump that has become noticeably noisier under load.\u003c\/p\u003e\n\u003cp\u003eWater at the weep holes between the water end and the crankcase is the unambiguous sign. \u003cstrong\u003eDo not keep running a pump that is weeping\u003c\/strong\u003e — the next thing to happen is water in the crankcase, and that turns a seal job into a pump.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eInspect the plungers before you fit new seals. Scoring, pitting or a dull worn band will destroy a new seal set quickly. Replacing seals twice costs more than replacing a plunger once.\u003c\/p\u003e\n\u003cp\u003eWork clean. A single piece of grit under a seal lip is a leak.\u003c\/p\u003e\n\u003cp\u003eFollow the pump manufacturer's torque figures on reassembly — uneven clamping distorts the seals and reproduces the fault you set out to fix.\u003c\/p\u003e\n\u003cp\u003eChange the crankcase oil at the same time, particularly if it has gone milky.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit my pump?\u003c\/h3\u003e\n\u003cp\u003eAsk us first. Triplex seal kits are not interchangeable between pump makes and we will not claim fitment we have not verified.\u003c\/p\u003e\n\u003ch3\u003eWhat is in the kit?\u003c\/h3\u003e\n\u003cp\u003eNot itemised in the documentation we hold. Ask us before ordering.\u003c\/p\u003e\n\u003ch3\u003eMy pump oil is milky. Is this the fix?\u003c\/h3\u003e\n\u003cp\u003eIt is usually part of it, but check the plungers for scoring and change the oil as well.\u003c\/p\u003e\n\u003ch3\u003eShould I do valves at the same time?\u003c\/h3\u003e\n\u003cp\u003eUsually yes — see 078-139.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eSend us the make and model of your pump, or a photo of its data plate, and we will confirm the correct kit before you order.\u003c\/p\u003e\n\u003ch2\u003eRelated pump parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/oil-seal-for-hydra-ii-pump\"\u003eOil Seal for Hydra II Pump (147-009)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/pump-4-0-gpm-gp\"\u003eEmperor General 3.4 GPM Pump (111-188)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672621639,"sku":"078-141","price":267.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Triplex-Pump-Seal-Kit.jpg?v=1780550282"},{"product_id":"kit-hydra-pump-ii-valves","title":"Hydra Pump II Valves Kit","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eValve kit for the HydraMaster Hydra Pump II and Hydra Pump 5. HydraMaster part number 000-078-159, listed as \u003cem\u003eKit, valves for Hydra Pump 2 and 5\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe valves are what make a positive-displacement pump a pump. They open and close on every stroke — thousands of times a minute — in water carrying whatever the machine has picked up.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eHydra Pump II\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eHydra Pump 5\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydraMaster's suggested spares schedule lists it against the \u003cstrong\u003eBoxxer 421\u003c\/strong\u003e and the \u003cstrong\u003eBoxxer 427\u003c\/strong\u003e. Because it is specified by pump, it suits any machine running either pump — check the pump, not the machine.\u003c\/p\u003e\n\n\u003ch2\u003eHow worn valves show themselves\u003c\/h2\u003e\n\u003cp\u003eWorn or fouled valves and worn seals produce similar symptoms, and telling them apart saves an unnecessary strip-down:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulsing or hammering\u003c\/strong\u003e that has got worse over time usually points at valves rather than seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure that will not reach the set point\u003c\/strong\u003e can be either — but if the pump is also weeping at the weep holes, start with seals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA pump that has become erratic rather than steadily weaker\u003c\/strong\u003e — a valve held open by debris, or a valve spring that has broken.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSudden loss of pressure with no leak\u003c\/strong\u003e — worth checking the valves before anything else.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDebris in a valve seat is the most common single cause and the easiest to prevent: it usually arrives through a neglected inlet screen or Y strainer.\u003c\/p\u003e\n\n\u003ch2\u003eRelated pump parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/kit-hydra-pump-ii-hot-seals\"\u003e\u003cstrong\u003e078-158\u003c\/strong\u003e — Hydra Pump II high-temperature seal kit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/oil-seal-for-hydra-ii-pump\"\u003e\u003cstrong\u003e147-009\u003c\/strong\u003e — crankcase oil seal\u003c\/a\u003e, 3 per pump\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHydraMaster also list 078-281, a piston seal kit specific to the Hydra Pump 5 on the Boxxer 427. It is not currently a stocked CCW line — ask us if you need one.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eKeep the valve assemblies in order and the right way up as they come out. They are not all identical and they do not all go back in the same orientation.\u003c\/p\u003e\n\u003cp\u003eInspect the seats as well as the valves. A pitted seat will not seal against a new valve, and that is a pump repair rather than a kit.\u003c\/p\u003e\n\u003cp\u003eCheck and clean the inlet filtration while you are at it. If debris caused this failure, it will cause the next one too.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eDoes it fit both the Hydra Pump 2 and 5?\u003c\/h3\u003e\n\u003cp\u003eYes — HydraMaster list it for both.\u003c\/p\u003e\n\u003ch3\u003eShould I do seals at the same time?\u003c\/h3\u003e\n\u003cp\u003eIf the pump has done real hours, yes. The seal kit is 078-158 and doing both means one strip-down.\u003c\/p\u003e\n\u003ch3\u003eWhat is in the kit?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not itemise the contents in the documentation we hold. Ask us if you need to know before ordering.\u003c\/p\u003e\n\u003ch3\u003eMy pump hammers. Valves or seals?\u003c\/h3\u003e\n\u003cp\u003eHammering and pulsing point at valves more often than seals. If it is also weeping, do both.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eTell us the pump and what it is doing and we will help you decide between a valve kit, a seal kit and both.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672625351,"sku":"078-159","price":435.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Hydra-Pump-II-Valves-Kit.jpg?v=1780550283"},{"product_id":"kit-s-s-float-splash-guard","title":"Float Splash Guard Kit for 157-0801","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eUpper recovery tank float splash guard kit. HydraMaster part number 000-078-357 \u003c\/p\u003e\n\u003cp\u003eThe kit fits a splash guard over the float on the recovery tank float shaft. It keeps the slurry, fibre and debris coming into a recovery tank off the float so the float can travel and report the level correctly.\u003c\/p\u003e\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eHydraMaster's installation sheet for this kit states that it applies to \u003cstrong\u003e157-0801 when used in a recovery tank\u003c\/strong\u003e. HydraMaster Tech Support describes the application as the recovery tank float splash guard for \u003cstrong\u003eall early units \u003c\/strong\u003eas now the 157-0801 is supplied with a splash guard.\u003c\/p\u003e\n\u003cp\u003eThe kit is installed on the stainless steel float and shaft already fitted in the tank. If your tank does not have the stainless steel float, it has to be retrofitted first, using HydraMaster's separate float retrofit instructions. If you are replacing the whole float assembly, see the \u003ca href=\"\/products\/switch-ss-float-recovery-tank\"\u003eHydraMaster Recovery Tank Float Switch (157-0801)\u003c\/a\u003e, which HydraMaster list as supplied with protector.\u003c\/p\u003e\n\u003ch2\u003eWhat is in the kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Switch Splash Guard Body\u003c\/li\u003e\n\u003cli\u003e1 x Switch Splash Guard Lid\u003c\/li\u003e\n\u003cli\u003e1 x 5\/16 inch × 2¾ inch rubber hose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe installation steps use:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea 5\/16 inch × 2¾ inch rubber hose, slid over the float shaft\u003c\/li\u003e\n\u003cli\u003ea two-part cover – a small cover that clicks onto the shaft and replaces the lower retaining clip, and a large cover that seats over it\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe stainless steel barrel and the top retaining clip are reused from the existing assembly.\u003c\/p\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cp\u003eThese steps follow HydraMaster's installation sheet. The sheet states no torque values or warnings.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eCheck that the stainless steel float is installed in the tank. If it is not, install it first using HydraMaster's float retrofit instructions.\u003c\/li\u003e\n\u003cli\u003eRemove the top retaining clip, the stainless steel barrel and the bottom retaining clip.\u003c\/li\u003e\n\u003cli\u003eLubricate the shaft with WD-40, then slide the rubber hose over the shaft until it rests against the end of the float shaft.\u003c\/li\u003e\n\u003cli\u003eSlide the small cover over the shaft until it clicks into place. It replaces the lower retaining clip. Keep the lower clip in case a replacement is needed later.\u003c\/li\u003e\n\u003cli\u003eSlide the stainless steel barrel over the shaft with the triangle facing up.\u003c\/li\u003e\n\u003cli\u003eSlide the large cover onto the small cover until it is fully seated.\u003c\/li\u003e\n\u003cli\u003eSecure the cover with the retaining clip.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/HydraMaster_078-357_Float_Splash_Guard_Installation.pdf?v=1793148662\"\u003eInstallation sheet, Upper Recovery Tank Float Splash Guard Kit, part 078-357\u003c\/a\u003e – HydraMaster instructions, digitally reformatted by CCW, English, no revision date stated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy a splash guard is not optional\u003c\/h2\u003e\n\u003cp\u003eA recovery tank float has to move freely to work. Everything the wand recovers arrives in that tank at speed – slurry, hair, fibre and grit – and a bare float gets loaded and wrapped within hours of heavy work.\u003c\/p\u003e\n\u003cp\u003eA float that cannot travel reports the wrong level. If it sticks low, the machine never sees the tank fill, and the next thing that happens is slurry in the blower. That is the failure this inexpensive part exists to prevent.\u003c\/p\u003e\n\u003cp\u003eIf you have found a barrel float switch in service without its guard, fit one. Do not treat it as an optional extra because the machine appeared to work without it.\u003c\/p\u003e\n\u003ch2\u003eMaintenance\u003c\/h2\u003e\n\u003cp\u003eClean the guard whenever you clean the tank. A guard packed solid with fibre protects the float from nothing and restricts it as effectively as the debris would have.\u003c\/p\u003e\n\u003cp\u003eInspect it for cracks. A cracked guard lets debris in at the split while still looking fitted.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit my machine?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster's installation sheet says all recovery tanks, and HydraMaster Tech Support describes it as the splash guard for all early units. Send us your model and serial number and we will check.\u003c\/p\u003e\n\u003ch3\u003eWhat is in the kit?\u003c\/h3\u003e\n\u003cp\u003eThe installation steps use a rubber hose and a two-part cover. HydraMaster's sheet has no parts list, so ask us to confirm the contents before ordering.\u003c\/p\u003e\n\u003ch3\u003eDoes the float switch come with one?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster describe 157-0801 as supplied \u003cem\u003ewith protector\u003c\/em\u003e. If you are replacing the whole switch you may not need this separately – ask us.\u003c\/p\u003e\n\u003ch3\u003eMy float is sticking. Is the guard the problem?\u003c\/h3\u003e\n\u003cp\u003eClean the float and the guard first. A packed guard and a fouled float produce the same symptom, and both cost nothing to check.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672634183,"sku":"078-357","price":45.05,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Clear_Lid_Translucent_Cup_and_Black_Hose.png?v=1793148387"},{"product_id":"kit-rtd-sensor-comp-fittin-575","title":"Titan 575 RTD Sensor Kit with Compression Fitting","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eRTD (Resistance Temperature Detector) sensor kit with compression fitting for the HydraMaster TITAN 575. CCW part reference 078-389.\u003c\/p\u003e\n\u003cp\u003eThe RTD is what the machine's temperature control reads. When it drifts or fails, the control system acts on a number that is not true — which is why a sensor fault can present as overheating, as a machine that never reaches temperature, or as readings that jump around while the machine itself is running normally.\u003c\/p\u003e\n\u003ch2\u003eWhat is in the kit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRTD sensor probe, stainless steel\u003c\/li\u003e\n\u003cli\u003eHigh-temperature sensor lead\u003c\/li\u003e\n\u003cli\u003eCompression fitting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSupplied complete, so the fitting does not have to be sourced separately.\u003c\/p\u003e\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/hydramaster-titan-575\"\u003eHydraMaster TITAN 575HP\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFitment to other machines has not been verified from a parts list. Send us your machine model and serial number and we will confirm before you order.\u003c\/p\u003e\n\u003ch2\u003eDiagnosis before replacement\u003c\/h2\u003e\n\u003cp\u003eErratic temperature readings, overheating warnings, or heat that will not hold are all worth checking at the sensor and its wiring before anything larger is suspected. An RTD reads by resistance, so a corroded terminal or a chafed lead produces the same symptom as a failed probe — and costs nothing to rule out.\u003c\/p\u003e\n\u003cp\u003eCheck the compression fitting is seated and the probe is fully inserted. A probe sitting proud of the flow reads the fitting rather than the solution, which gives a low and lazy reading.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/sender-s-w-temp-1-4-threads\"\u003eTemperature Sender 1\/4 inch (149-002)\u003c\/a\u003e — feeds the dash gauge, a different device from the control RTD\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/sensor-285-deg-nason\"\u003eNason 285 Degree Sensor Kill Switch (149-027)\u003c\/a\u003e — high temperature shutdown, fixed set point\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/valve-cat-thermo-180deg\"\u003eCAT Thermo Valve 180° (169-011)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs this the same as the dash temperature sender?\u003c\/h3\u003e\n\u003cp\u003eNo. The sender drives the gauge you read; the RTD feeds the control system. A machine can have a healthy gauge and a failed RTD, or the reverse.\u003c\/p\u003e\n\u003ch3\u003eCan I test it rather than replace it?\u003c\/h3\u003e\n\u003cp\u003eYes. An RTD changes resistance with temperature, so it can be checked with a multimeter as the machine warms. A reading that does not move, or an open circuit, confirms it.\u003c\/p\u003e\n\u003ch3\u003eDoes it include the compression fitting?\u003c\/h3\u003e\n\u003cp\u003eYes. Probe, lead and fitting are supplied together.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eSend us your machine model and serial number and we will confirm the correct sensor before you order.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672639687,"sku":"078-389","price":862.79,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Titan_575_RTD_Sensor_Kit_with_Compression_Fitting.png?v=1780707201"},{"product_id":"lamp-red-pilot-round","title":"Red Pilot Light - Round","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eRed pilot light, round. HydraMaster part number 000-084-006.\u003c\/p\u003e\n\u003cp\u003eIt is the indicator lamp on the machine's control panel. Small, cheap, and worth replacing the moment it fails — because a warning lamp that does not light is worse than no lamp at all.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCDS 4.2 \/ 4.7\u003c\/strong\u003e — \u003cem\u003eLamp, Red Pilot – Round\u003c\/em\u003e, 2 fitted\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 3.2\u003c\/strong\u003e — \u003cem\u003eLamp, Red Pilot – Round\u003c\/em\u003e, 1 to 2 fitted depending on the assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCCW's own record also notes it as used on older HydraMaster units. Those are the machines we can name from the parts lists we hold; round panel indicators of this type are used elsewhere in the range, but we are not going to claim fitment we have not verified. Send us your machine model and we will check its parts list before you order.\u003c\/p\u003e\n\n\u003ch2\u003eWhy a dead indicator matters\u003c\/h2\u003e\n\u003cp\u003ePanel lamps exist to tell an operator something before it becomes expensive — a circuit live, a fault condition, a system on when it should be off. Once the lamp has failed, the operator quietly stops relying on that information and the machine loses a layer of protection nobody notices has gone.\u003c\/p\u003e\n\u003cp\u003eThe other reason to fix it promptly is diagnostic. A lamp that has failed makes fault-finding harder for whoever works on the machine next, because they cannot tell whether the circuit is dead or just the indicator.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eIsolate the circuit before you start. It is a low-voltage panel, but a spanner across a live terminal in a tight console still makes a mess.\u003c\/p\u003e\n\u003cp\u003eCheck the panel cut-out diameter and the mounting arrangement before you order if you are replacing a lamp on a machine that is not on the list above. Round panel indicators come in several standard sizes and they are not interchangeable.\u003c\/p\u003e\n\u003cp\u003eBefore you condemn a lamp, check that it is actually the lamp — measure for voltage at the holder. A dead indicator is quite often a broken earth or a failed switch, and replacing the lamp will not fix either.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat voltage is it?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not state the lamp voltage in the parts lists we hold. The CDS control circuits are 12 V DC, but we are not going to publish a rating we have not verified. Ask us and we will confirm before you order.\u003c\/p\u003e\n\u003ch3\u003eWhat panel hole does it need?\u003c\/h3\u003e\n\u003cp\u003eNot stated in the documentation we hold. Measure your existing cut-out, or send us a photo, and we will confirm.\u003c\/p\u003e\n\u003ch3\u003eIs it LED or filament?\u003c\/h3\u003e\n\u003cp\u003eNot stated. Ask us if it matters for your application.\u003c\/p\u003e\n\u003ch3\u003eMy lamp is out but the system works. Do I need to fix it?\u003c\/h3\u003e\n\u003cp\u003eYes. The lamp is there to tell you something. A machine that has lost its indicators has lost information the next person to work on it will need.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eSend us your machine model, serial number and a photo of the panel and we will confirm the correct indicator before you order.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eMore \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e parts and equipment, and the full range in \u003ca href=\"\/collections\/parts-maintenance\"\u003eParts \u0026amp; Maintenance\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/switch-relay-a-c-b-c-cds\"\u003eHydraMaster Relay Switch A\/C B\/C CDS (157-022)\u003c\/a\u003e — 12V relay from the same control circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/regulator-3-amp-1000-piv-diode\"\u003eRegulator 3AMP 1000 PIV DIODE (135-051)\u003c\/a\u003e — inline diode, 3 amp\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672651207,"sku":"084-006","price":40.64,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Red-Pilot-Light-Round.jpg?v=1780550287"},{"product_id":"o-ring-set-hydramaster-pressure-regulator","title":"O-Ring Kit for HydraMaster 169-101 Pressure Regulator","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eSeal set for the HydraMaster high-pressure by-pass valve, listed in the parts list as \u003cem\u003eSeal Set for By-pass Valve\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe by-pass valve regulates solution pressure and dumps the excess back to the water box. When its seals wear, pressure becomes unstable or will not hold at the set point — the machine reads fine at rest and drops away under trigger.\u003c\/p\u003e\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBy-pass valve \u003cstrong\u003e169-101\u003c\/strong\u003e (Valve, By-Pass Truckmount)\u003c\/li\u003e\n\u003cli\u003eItem 3 in the by-pass valve assembly, fitted with seat and o-ring 148-004, fitting o-ring 097-005 and high-PSI spring 155-019\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRepairing the whole valve\u003c\/h2\u003e\n\u003cp\u003eHydraMaster also list two kits that contain this seal set:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e078-101\u003c\/strong\u003e — seal and spring kit for the high-PSI by-pass (includes this seal set and the spring)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e078-102\u003c\/strong\u003e — complete by-pass repair kit (includes 078-101)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeither kit is currently held by CCW. If the valve is worn enough to need the spring as well, contact us before ordering the seal set on its own.\u003c\/p\u003e\n\u003ch2\u003eIdentifying the right part\u003c\/h2\u003e\n\u003cp\u003eCCW part codes are the HydraMaster part number with the \u003ccode\u003e000-\u003c\/code\u003e prefix removed — this item is HydraMaster P\/N \u003cstrong\u003e000-097-028\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eHydraMaster truckmounts share components across models and production years. If you are ordering for an existing machine, send us the model and serial number from the data plate and we will check it against the parts list for your machine.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster \u003cstrong\u003eCDS 4.2 \/ 4.7\u003c\/strong\u003e machine assemblies and parts lists. Fitment to other HydraMaster models has not been verified from a parts list — ask us if you are ordering for a different machine.\u003c\/p\u003e\u003chr\u003e\u003cp\u003eO-Ring Kit for HydraMaster 169-101 bypass valve\u003c\/p\u003e\n\u003ch2\u003eImportant — two o-ring kits, two different valves\u003c\/h2\u003e\n\u003cp\u003eCCW lists an o-ring kit for the solution valve and a seal set for the by-pass valve. They service different valves and do not interchange.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eThis seal set (097-028)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"\/products\/repair-o-ring-kit-hydramaster-solution-valve\"\u003e078-019\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve\u003c\/td\u003e\n\u003ctd\u003eBy-pass valve \u003cstrong\u003e169-101\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSolution valve \u003cstrong\u003e169-058\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhat it does\u003c\/td\u003e\n\u003ctd\u003eRegulates solution pressure, dumps excess to the water box\u003c\/td\u003e\n\u003ctd\u003eThe trigger valve in the wand or tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSymptom\u003c\/td\u003e\n\u003ctd\u003ePressure unstable, or will not hold at the set point — reads fine at rest and drops away under trigger\u003c\/td\u003e\n\u003ctd\u003eTrigger valve weeps, or will not shut cleanly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/repair-o-ring-kit-hydramaster-solution-valve\"\u003eRepair O-Ring Kit, Solution Valve (078-019)\u003c\/a\u003e — the other valve; see the table above\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/valve-cat-thermo-180deg\"\u003eCAT Thermo Valve 180° (169-011)\u003c\/a\u003e — high temperature control in the same circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eMy pressure drops away under trigger. Is this the fix?\u003c\/h3\u003e\n\u003cp\u003eIt is the first thing to check. Worn by-pass seals let pressure bleed off under load while the gauge still reads correctly at rest.\u003c\/p\u003e\n\u003ch3\u003eIs this the same as the solution valve kit?\u003c\/h3\u003e\n\u003cp\u003eNo. See the table above — different valve, different symptom.\u003c\/p\u003e\n\u003ch3\u003eDo you stock the complete by-pass valve?\u003c\/h3\u003e\n\u003cp\u003eNot as a listed line. Send us your machine model and serial number and we will work out what you need.\u003c\/p\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672653895,"sku":"097-028","price":34.65,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/O-Ring-Kit-for-HydraMaster-169-101-Pressure-Regulator.jpg?v=1780550288"},{"product_id":"kleenrite-v-boost-vac-booster","title":"KleenRite V-Boost Vac Booster","description":"\u003cp\u003eThe KleenRite V-Boost is an inline vacuum booster for portable carpet extractors. It sits in the vacuum hose run and adds airflow, so a portable can keep its recovery performance on long hose runs. KleenRite state it increases airflow by up to 135% and allows portables to clean with hose runs of over 30 m.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/KLEENRITE_V-BOOST_VAC_BOOSTER_1_480x480.jpg?v=1599632889\" alt=\"KleenRite V-Boost vacuum booster\"\u003e\u003c\/p\u003e\n\u003ch2\u003eElectrical\u003c\/h2\u003e\n\u003cp\u003eCCW supplies the V-Boost as a 230 V unit with an Australian plug. KleenRite's published description is for the US model. Check your site's circuits: a booster and an extractor on the same circuit can trip it.\u003c\/p\u003e\n\u003ch2\u003eConstruction\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRotationally moulded polyethylene base, tank and handle\u003c\/li\u003e\n\u003cli\u003e100 mm (4 in) rear wheels and pull-up handle for transport\u003c\/li\u003e\n\u003cli\u003eLow centre of gravity for stability\u003c\/li\u003e\n\u003cli\u003eAccess plate underneath for servicing components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e2 in vacuum ports for maximum airflow\u003c\/li\u003e\n\u003cli\u003eVacuum filter screen and ball-float shut-off to stop overflow reaching the vacuum motor\u003c\/li\u003e\n\u003cli\u003eClear dome lid for access to the waste tank\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eKleenRite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCCW SKU\u003c\/th\u003e\n\u003ctd\u003e100-602-VACBOOST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVacuum ports\u003c\/th\u003e\n\u003ctd\u003e2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003eRotomoulded polyethylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWheels\u003c\/th\u003e\n\u003ctd\u003e4 in rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverflow protection\u003c\/th\u003e\n\u003ctd\u003eFilter screen and ball-float shut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e230 V, Australian plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhy do I need a booster?\u003c\/h3\u003e\n\u003cp\u003eVacuum falls off with hose length. A booster adds airflow part-way along the run so the wand still recovers properly.\u003c\/p\u003e\n\u003ch3\u003eHow long a hose run can I use?\u003c\/h3\u003e\n\u003cp\u003eKleenRite state over 30 m with the V-Boost.\u003c\/p\u003e\n\u003ch3\u003eWill it suit my extractor?\u003c\/h3\u003e\n\u003cp\u003eIt has 2 in ports. Tell us your machine and hose sizes and we will confirm.\u003c\/p\u003e\n\u003ch3\u003eWhat power does it need?\u003c\/h3\u003e\n\u003cp\u003e230 V from a standard Australian outlet. Put it on a different circuit from the extractor where you can.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eTell us your extractor, hose sizes and typical hose run, and we will confirm the V-Boost suits before you order.\u003c\/p\u003e","brand":"Kleenrite","offers":[{"title":"EACH","offer_id":50672668935,"sku":"100-602-VACBOOST","price":2134.28,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/KleenRite-V-Boost-Vac-Booster.jpg?v=1780550289"},{"product_id":"coupling-rubber-plug-boxxer-421","title":"HydraMaster Boxxer 421 Coupling Rubber Plug","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eRubber drive coupling plug for the coupler between the engine and the blower. HydraMaster part number 000-106-045, listed as \u003cem\u003ePlug, HD4 Coupling — 1\" O.D. × 7\/8\" Lg., 70 durometer EPDM\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA coupler takes eight plugs.\u003c\/strong\u003e They are a wear item, and they are the part that stands between the engine and the blower.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOutside diameter: 1 inch\u003c\/li\u003e\n\u003cli\u003eLength: 7\/8 inch\u003c\/li\u003e\n\u003cli\u003eMaterial: EPDM, 70 durometer\u003c\/li\u003e\n\u003cli\u003eCoupling type: HD4\u003c\/li\u003e\n\u003cli\u003eQuantity per coupler: 8\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eBoxxer 421\u003c\/strong\u003e — 8 fitted; also listed as a scheduled replacement item in the machine's maintenance schedule\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 4.0\u003c\/strong\u003e — 8 fitted (machine assembly item 22)\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCM402\u003c\/strong\u003e — 8 fitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFitted alongside 5 inch retaining ring 139-022 and washer 174-080 in the coupler assembly.\u003c\/p\u003e\n\n\u003ch2\u003eWhy the plugs matter more than they look\u003c\/h2\u003e\n\u003cp\u003eThe plugs are the flexible element in the drive between the engine and the blower. They absorb the torsional shock of engine firing pulses and take up the small misalignment that exists in every real installation. When they harden and wear, that shock and misalignment go into the blower bearings and the engine crankshaft instead.\u003c\/p\u003e\n\u003cp\u003eThey wear gradually and quietly. The first sign is usually a knock or rattle from the coupler at idle or on shutdown, or a machine that has developed a vibration it did not have. By then the plugs have been passing shock through for a while.\u003c\/p\u003e\n\u003cp\u003eHydraMaster treat plug replacement as scheduled maintenance on the Boxxer 421, not as a repair. That is the right way to think about them.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eReplace all eight together.\u003c\/strong\u003e Mixing new and used plugs loads the new ones unevenly and they will not last.\u003c\/p\u003e\n\u003cp\u003eCheck coupler alignment while you have it apart. Plugs that have worn unevenly — some flattened, some barely marked — are telling you the coupler is out of alignment, and new plugs will wear the same way if you do not correct it. HydraMaster publish a coupler alignment procedure for exactly this reason.\u003c\/p\u003e\n\u003cp\u003eCheck the coupler retaining bolts and the engine and blower mounting bolts at the same time. HydraMaster call this out specifically in the maintenance schedule.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eEight per coupler. Order eight.\u003c\/p\u003e\n\u003ch3\u003eCan I replace just the worn ones?\u003c\/h3\u003e\n\u003cp\u003eNo. Mixed plugs load unevenly and the new ones fail early.\u003c\/p\u003e\n\u003ch3\u003eHow often should they be replaced?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster list plug replacement on a scheduled interval for the Boxxer 421. Machines doing high hours, or with a history of alignment problems, need them sooner.\u003c\/p\u003e\n\u003ch3\u003eMy plugs wore unevenly. Is that normal?\u003c\/h3\u003e\n\u003cp\u003eNo — it is an alignment symptom. Correct the alignment before you fit new plugs or you will be doing the job again.\u003c\/p\u003e\n\u003ch3\u003eIs there a different plug for other machines?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster list other coupler sleeves and inserts for other drives — for example 152-008 and 152-010. Do not assume the HD4 plug carries across. Send us your machine model and we will check.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eHearing a knock from the coupler? Tell us the machine and the symptom and we will help you sort a plug replacement from an alignment problem before you order.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eMore \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e parts and equipment, and the full range in \u003ca href=\"\/collections\/parts-maintenance\"\u003eParts \u0026amp; Maintenance\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/sleeve-6-drive-coupler-spitfire-sidekick\"\u003eSleeve #6 Drive Coupler Spitfire Sidekick (152-008)\u003c\/a\u003e — #6 drive coupler sleeve\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/coupler-sleeve-7-drive-coupler\"\u003eCoupler Sleeve #7 Drive Coupler (152-009)\u003c\/a\u003e — #7 drive coupler sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672676551,"sku":"106-045","price":20.79,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/HydraMaster-Boxxer-421-Coupling-Rubber-Plug.jpg?v=1780550290"},{"product_id":"pump-air-maxx-450-470-javelin","title":"Air Pump Maxx 450 470 Javelin","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eAir pump for the HydraMaster MAXX 450D and 470D, new style. HydraMaster part number 000-111-085, listed as \u003cem\u003ePump, Air N\/S\u003c\/em\u003e and, in the suggested spares schedule, as \u003cem\u003epump, air Maxx 450\/470, new style\u003c\/em\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eMAXX 450D\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eMAXX 470D\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is item 2 in the MAXX air pump assembly (drawing C-5383 Rev A), fitted with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e015-724\u003c\/strong\u003e — bracket, air pump \/ alternator mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e154-092\u003c\/strong\u003e — spacer, air pump pulley, 17 mm bore\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e109-083\u003c\/strong\u003e — pulley, AK30 modified to 17 mm bore\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe MAXX hose schedule shows it fed from the air filter by a 22 inch hose, with an air pump hose adapter on the outlet.\u003c\/p\u003e\n\u003cp\u003eCCW's record also associates this pump with the Javelin.\u003c\/p\u003e\n\n\u003ch2\u003eImportant — \"new style\" is part of the description\u003c\/h2\u003e\n\u003cp\u003eHydraMaster's own wording is \u003cem\u003enew style\u003c\/em\u003e, which means there is an old style. If your machine has never had this pump replaced and is an early MAXX, do not assume the mounting, the pulley bore and the hose connections match.\u003c\/p\u003e\n\u003cp\u003eNote in particular the 17 mm pulley bore and the AK30 pulley modified to suit. If your existing pulley and spacer are a different bore, they will not transfer to this pump.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSend us the machine serial number before ordering.\u003c\/strong\u003e This is an expensive part to get wrong.\u003c\/p\u003e\n\n\u003ch2\u003eService advice\u003c\/h2\u003e\n\u003cp\u003eAir pumps on truckmounts fail for two reasons more than any other: running with a blocked or missing air filter, and belt tension set by feel rather than to specification.\u003c\/p\u003e\n\u003cp\u003eCheck the air filter and the inlet hose before you condemn a pump that is not making pressure. A collapsed or split inlet hose reads exactly like a worn pump.\u003c\/p\u003e\n\u003cp\u003eSet belt tension properly when you fit a new pump. Over-tension destroys the pump bearing; under-tension glazes the belt and cooks the pulley.\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/valve-pressure-regulator-bx421-bx427-mx450-mx470\"\u003ePressure Regulator Valve BX421, BX427, MX450 \u0026amp; MX470 (169-083)\u003c\/a\u003e — listed for the same MAXX machines\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/valve-prim-vac-sol-bxmxcds\"\u003eMac Solenoid (Boxxer, MAXX, CDS) (169-070)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit an older MAXX?\u003c\/h3\u003e\n\u003cp\u003eNot necessarily. It is the new-style pump. Send us the serial number and we will check.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with the pulley and bracket?\u003c\/h3\u003e\n\u003cp\u003eThey are separate part numbers — 109-083 pulley, 154-092 spacer, 015-724 bracket. We have not verified what is supplied in the box. Ask us before ordering if you need them.\u003c\/p\u003e\n\u003ch3\u003eWhat pressure does it deliver?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster does not state the pump's output specification in the parts lists we hold, and we are not going to publish a figure we cannot verify. Ask us if you need the specification.\u003c\/p\u003e\n\u003ch3\u003eMy air system is weak. Is it the pump?\u003c\/h3\u003e\n\u003cp\u003eCheck the filter, the inlet hose and the belt first. All three read like a worn pump and all three are cheaper.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eSend us your MAXX serial number before ordering — the old-style and new-style pumps differ, and we would rather check than have you fit the wrong one.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003eMore \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e parts and equipment, and the full range in \u003ca href=\"\/collections\/parts-maintenance\"\u003eParts \u0026amp; Maintenance\u003c\/a\u003e.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672684423,"sku":"111-085","price":1347.89,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Air-Pump-Maxx-450-470-Javelin.jpg?v=1780550290"},{"product_id":"pump-4-0-gpm-gp","title":"Emperor General 3.4 GPM Pump EPHT1813S","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eGeneral Pump EPHT1813S solution pump, 3.4 GPM. A replacement pump for HydraMaster and Sapphire truckmounts.\u003c\/p\u003e\n\u003cp\u003eListed in the HydraMaster TITAN 575 parts book.\u003c\/p\u003e\n\u003cp\u003eDesigned for durability and compatibility, the EPHT1813S makes installation easy, making it a seamless choice for professionals replacing existing pumps without hassle. With its robust construction, this pump is built to withstand frequent use, delivering dependable water flow for effective cleaning.\u003c\/p\u003e\n\u003cp\u003eEnsure your carpet cleaning machine runs at its best by replacing worn pumps with the Emperor General 3.4 GPM Pump EPHT1813S. Continue delivering top-notch service to your customers without interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES\u003c\/strong\u003e\u003cbr\u003e• Features patented \"high-tech\" packings:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003edynamic low-pressure seal retainer\u003c\/li\u003e\n\u003cli\u003esuperior low-pressure seal\u003c\/li\u003e\n\u003cli\u003einnovative intermediate ring\u003c\/li\u003e\n\u003cli\u003esuperior high-pressure seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e• Nickel-plated manifold\u003cbr\u003e• New forged brass manifold, increases working pressure to 4,000 PSI\u003cbr\u003e• New plunger guide bushing (patent pending)\u003cbr\u003e• Solid ceramic plungers with a dual guide system\u003cbr\u003e• New dual-diameter plunger guide\u003cbr\u003e• New optimised outlet valves\u003cbr\u003e• New dual lip oil seal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eThis pump replaces HTXS1813S, 111-188 \u0026amp; 46-063 — the superseded General pump catalogued by Legend Brands as 119110.\u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/EPHT1812S-pump-1.pdf?v=1733714888\" target=\"_blank\"\u003eEPHT1813S Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/hydramaster-titan-575\"\u003eHydraMaster TITAN 575HP\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/oil-seal-for-hydra-ii-pump\"\u003eOil Seal for Hydra II Pump (147-009)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTITAN 425 fitment\u003c\/h2\u003e\n\u003cp\u003eNamed in the parts listing for the \u003cstrong\u003eHydraMaster TITAN 425\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePump Assembly (610-007-728 Rev C) — \u003cstrong\u003e1\u003c\/strong\u003e — listed as \u003cem\u003ePump, 4.0 gpm GP\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNote on the flow rating.\u003c\/strong\u003e HydraMaster lists this pump as 4.0 gpm in the TITAN 425 parts book, alongside a 4.0 gpm clutch plate and adapter. CCW records it as 3.4 GPM. Tell us your machine and we will confirm the correct pump before you order.\u003c\/p\u003e\n\u003cp\u003eVerified from the HydraMaster \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Titan_425_Parts_Listing_HQ_SEARCHABLE_LANDSCAPE_FINAL.pdf?v=1787560109\"\u003eTITAN 425 parts listing\u003c\/a\u003e, MAN-47791 Rev A.\u003c\/p\u003e\n","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672686919,"sku":"111-188","price":2884.6,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Emperor-General-3_4-GPM-Pump-EPHT1813S.jpg?v=1780550291"},{"product_id":"regulator-3-amp-1000-piv-diode","title":"Regulator 3AMP 1000 PIV DIODE","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eInline diode, 3 amp, 1000 PIV. HydraMaster part number 000-135-051, listed as \u003cem\u003eRegulator, 3 Amp 1000 PIV Diode\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is a one-way valve for electricity. In a truckmount it is normally there to protect the control circuit from the reverse voltage spike that a solenoid or relay coil produces when it switches off — a spike that will otherwise find its way into whatever else is on that circuit.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eHydraMaster's suggested spares schedule lists it against six machines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoxxer 421\u003c\/li\u003e\n\u003cli\u003eBoxxer 427\u003c\/li\u003e\n\u003cli\u003eCDS 4.6 \/ CDS 4.8\u003c\/li\u003e\n\u003cli\u003eCTS450\u003c\/li\u003e\n\u003cli\u003eMAXX 450D \/ 470D\u003c\/li\u003e\n\u003cli\u003eSpitFire 3.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is also named in the parts lists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoxxer 318HP\u003c\/strong\u003e — \u003cem\u003eRegulator, 3 Amp 1000 PIV Diode\u003c\/em\u003e, 1 fitted\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpitFire 3.2\u003c\/strong\u003e and \u003cstrong\u003eSpitFire 4.0\u003c\/strong\u003e — listed as \u003cem\u003eDiode\u003c\/em\u003e, 1 each\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrossfire 3.7\u003c\/strong\u003e and \u003cstrong\u003eCrossfire 4.2\u003c\/strong\u003e — listed as \u003cem\u003eDiode\u003c\/em\u003e, 1 each\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThat is nine machines, which makes this one of the most widely shared electrical components in the HydraMaster range.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eForward current: 3 A\u003c\/li\u003e\n\u003cli\u003ePeak inverse voltage: 1000 PIV\u003c\/li\u003e\n\u003cli\u003eStyle: inline\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePolarity matters.\u003c\/strong\u003e A diode fitted the wrong way round will either do nothing or short the circuit it was meant to protect. Note the orientation and the band on the body before you remove the old one, and take a photo.\u003c\/p\u003e\n\u003cp\u003eIsolate the circuit before you start. Diodes are usually in the loom near the component they protect, and there is rarely much room to work.\u003c\/p\u003e\n\u003cp\u003eA failed diode does not always look failed. If a solenoid circuit has been misbehaving — a relay chattering, a control board doing something inexplicable, a switch that works intermittently — check the diode before you replace anything expensive. It is the cheapest part in that circuit and one of the most common causes.\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/switch-relay-a-c-b-c-cds\"\u003eHydraMaster Relay Switch A\/C B\/C CDS (157-022)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/valve-solinoid-12-volt\"\u003eValve Solenoid 12 Volt (169-120)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhich way round does it go?\u003c\/h3\u003e\n\u003cp\u003eThe same way as the one you removed. Photograph it before you take it out. If it is already gone, do not guess — send us a photo of the circuit and we will help.\u003c\/p\u003e\n\u003ch3\u003eCan I use a generic diode of the same rating?\u003c\/h3\u003e\n\u003cp\u003eElectrically an equivalent part will work. HydraMaster specify this one, and on a machine under warranty that matters.\u003c\/p\u003e\n\u003ch3\u003eHow do I test it?\u003c\/h3\u003e\n\u003cp\u003eWith a multimeter on diode range: it should conduct one way and not the other. A diode that conducts both ways or neither way is finished.\u003c\/p\u003e\n\u003ch3\u003eHow many are fitted?\u003c\/h3\u003e\n\u003cp\u003eTypically one, but it depends on the machine. Check the wiring diagram for your model.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eChasing an electrical fault? Tell us the machine and the symptom — a cheap diode is very often the answer and we would rather you checked it before ordering a control board.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672688519,"sku":"135-051","price":5.25,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Regulator-3AMP-1000-PIV-DIODE.jpg?v=1780550292"},{"product_id":"oil-seal-for-hydra-ii-pump","title":"Oil Seal for Hydra II Pump (3 per Pump)","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eOil seal for the HydraMaster Hydra Pump II. HydraMaster part number 000-147-009, listed as \u003cem\u003eSeal, oil seal for HydraPump 2\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree are required per pump.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eHydraMaster's suggested spares schedule lists it against:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eBoxxer 421\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 3.2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAny machine running a Hydra Pump II uses this seal. If you know your pump is a Hydra Pump II, this is the seal — check the pump, not the machine.\u003c\/p\u003e\n\n\u003ch2\u003eWhere it sits in a pump rebuild\u003c\/h2\u003e\n\u003cp\u003eThe oil seals separate the crankcase from the water end. When they fail you get oil where water should be, water where oil should be, or both — and a pump that is milking its oil is on a clock.\u003c\/p\u003e\n\u003cp\u003eHydraMaster list three service kits for the Hydra Pump II, and they cover different things:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e147-009\u003c\/strong\u003e — oil seals (this part), 3 per pump\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/kit-hydra-pump-ii-hot-seals\"\u003e\u003cstrong\u003e078-158\u003c\/strong\u003e — Hydra Pump II high-temperature seal kit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/kit-hydra-pump-ii-valves\"\u003e\u003cstrong\u003e078-159\u003c\/strong\u003e — Hydra Pump II valve kit\u003c\/a\u003e (also covers the Hydra Pump 5)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA full pump service normally wants more than one of these. Ask us before you order a single item.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eReplace all three together. They have done the same hours in the same conditions.\u003c\/p\u003e\n\u003cp\u003eInspect the plungers or shafts the seals run on while you have the pump apart. A scored plunger will destroy new seals quickly, and fitting new seals to a scored surface is money spent twice.\u003c\/p\u003e\n\u003cp\u003eFit seals the right way round — the lip faces the pressure it is sealing against. It is an easy thing to get wrong on a bench at the end of a long day and an expensive one to discover afterwards.\u003c\/p\u003e\n\u003cp\u003eChange the crankcase oil when you rebuild. Milky oil means water has been through the crankcase, and the old oil is carrying whatever wore the seals out.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow many do I need?\u003c\/h3\u003e\n\u003cp\u003eThree per pump.\u003c\/p\u003e\n\u003ch3\u003eIs this the same as the hot seal kit?\u003c\/h3\u003e\n\u003cp\u003eNo. 078-158 is the high-temperature seal kit for the water end. These are the crankcase oil seals. Different parts, different job.\u003c\/p\u003e\n\u003ch3\u003eMy pump oil has gone milky. Is this the fix?\u003c\/h3\u003e\n\u003cp\u003eIt is usually part of it. Milky oil means water is getting past the seals — but check the plungers for scoring at the same time, or you will be doing it again.\u003c\/p\u003e\n\u003ch3\u003eDoes it suit the Hydra Pump 5?\u003c\/h3\u003e\n\u003cp\u003eNot confirmed in the documentation we hold. The valve kit 078-159 covers both the Hydra Pump 2 and 5, but the oil seal is listed for the Hydra Pump 2. Ask us with your pump details.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eRebuilding a Hydra Pump II? Tell us what you have found and we will put the right combination of seals, valve kit and oil seals together so the pump only comes apart once.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672692423,"sku":"147-009","price":36.98,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Oil-Seal-for-Hydra-II-Pump-3-per-Pump.jpg?v=1780550292"},{"product_id":"sender-s-w-temp-1-4-threads","title":"HydraMaster Temperature Sensor Gauge 1\/4\"","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eTemperature sender with 1\/4 inch threads, listed by HydraMaster as \u003cem\u003eSender, s\/w Temp\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt feeds the dash temperature gauge. A failed sender reads cold or pegs high while the machine is in fact running normally — worth confirming before chasing a heat fault that does not exist.\u003c\/p\u003e\n\u003ch2\u003eWhere it is fitted\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInstrument panel assembly — \u003cstrong\u003e1 per machine\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDrives the water temperature gauge 000-074-001\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIdentifying the right part\u003c\/h2\u003e\n\u003cp\u003eCCW part codes are the HydraMaster part number with the \u003ccode\u003e000-\u003c\/code\u003e prefix removed — this item is HydraMaster P\/N \u003cstrong\u003e000-149-002\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eHydraMaster truckmounts share components across models and production years. If you are ordering for an existing machine, send us the model and serial number from the data plate and we will check it against the parts list for your machine.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster \u003cstrong\u003eCDS 4.2 \/ 4.7\u003c\/strong\u003e machine assemblies and parts lists. Fitment to other HydraMaster models has not been verified from a parts list — ask us if you are ordering for a different machine.\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003e¼\" MPT Hydramaster SW Temperature Sensor Gauge. \u003c\/p\u003e\n\n\u003ch2\u003eRelated sensors\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/sensor-285-deg-nason\"\u003eNason 285 Degree Sensor Kill Switch (149-027)\u003c\/a\u003e — high temperature shutdown, not a gauge sender\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sensor-235deg-nason-snap-disc\"\u003eNason Snap Disc Sensor 235F (149-0181)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eThe gauge reads cold but the machine is hot. Sender or gauge?\u003c\/h3\u003e\n\u003cp\u003eStart with the sender. It is the cheaper part and the more common failure, and a sender that has gone open circuit reads cold regardless of actual temperature.\u003c\/p\u003e\n\u003ch3\u003eIs this the same as the high temperature shutdown sensor?\u003c\/h3\u003e\n\u003cp\u003eNo. This sender feeds the dash gauge. The shutdown sensor is a separate switch with a fixed set point — different job, different part.\u003c\/p\u003e\n\u003ch3\u003eCan I test it before replacing it?\u003c\/h3\u003e\n\u003cp\u003eYes, with a multimeter across the sender while the machine warms. Resistance should change smoothly with temperature. No change, or an open circuit, confirms it.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672693063,"sku":"149-002","price":123.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/HydraMaster-Temperature-Sensor-Gauge-14.jpg?v=1780550293"},{"product_id":"sensor-185-deg-phase","title":"Sensor 185 Deg - Phase","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eTemperature switch, 185 °F (approximately 85 °C). HydraMaster part number 000-149-0111, cross-referenced by Bridgepoint as \u003cstrong\u003ePHY149-0111\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is a snap-disc thermal switch: a sealed device that changes state at a fixed temperature. There is nothing to adjust and nothing to calibrate — the set point is the part number.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eVerified from the Bridgepoint parts catalogue temperature control cross-reference:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 4.0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCrossfire 4.2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOld-style machines only\u003c\/strong\u003e — the cross-reference is explicit that this switch belongs to the versions \u003cem\u003ewithout adjustable thermostat control\u003c\/em\u003e. If your machine has an adjustable thermostat, this is not your part.\u003c\/p\u003e\n\n\u003ch2\u003eImportant — the set point is the part\u003c\/h2\u003e\n\u003cp\u003eHydraMaster use several fixed-temperature switches that look identical and are not interchangeable. Fitting the wrong one either cuts the machine out early or fails to protect it at all:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-0111\u003c\/strong\u003e — 185 °F (85 °C) — SpitFire 4.0, Crossfire 4.2, old style\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-021\u003c\/strong\u003e — 218 °F (103 °C) — CDS 4.2, 4.7, 4.6 and 4.8\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sensor-235deg-nason-snap-disc\"\u003e\u003cstrong\u003e149-0181\u003c\/strong\u003e — 235 °F (113 °C) — Crossfire 4.4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-505\u003c\/strong\u003e — 240 °F (116 °C) — MAXX 450D and 470D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-013\u003c\/strong\u003e — 245 °F (118 °C) — Crossfire 3.7 and 4.2\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sensor-285-deg-nason\"\u003e\u003cstrong\u003e149-027\u003c\/strong\u003e — 285 °F (141 °C) — SpitFire 4.0, Boxxer 421, Crossfire 4.4, MAXX 550\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote that the Crossfire 4.2 appears against both 185 °F and 245 °F — the two switches do different jobs in the same machine. \u003cstrong\u003eRead the temperature marked on the switch you are replacing before you order.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eRead the old switch before you remove it. The set point is normally stamped or printed on the body, and it is the only reliable way to identify what you actually need.\u003c\/p\u003e\n\u003cp\u003eNote the orientation and the terminal positions, and photograph the wiring. Some thermal switches are normally open and some normally closed; getting that wrong will either leave the circuit permanently made or permanently broken.\u003c\/p\u003e\n\u003cp\u003eFit it in the same location, with the same thread sealant arrangement. A thermal switch that is not in proper contact with what it is sensing reads late, which defeats the point of it.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if mine is the old style?\u003c\/h3\u003e\n\u003cp\u003eIf your machine has an adjustable thermostat control, this is not your switch. If it does not, and the switch you are replacing is marked 185 °F, it is.\u003c\/p\u003e\n\u003ch3\u003eCan I fit a higher-rated switch?\u003c\/h3\u003e\n\u003cp\u003eNo. The set point is what protects the machine. A higher switch will let the machine run past the temperature it was designed to cut out at.\u003c\/p\u003e\n\u003ch3\u003eIs it adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. It is a fixed-set-point device.\u003c\/p\u003e\n\u003ch3\u003eIs it the same as the Bridgepoint part?\u003c\/h3\u003e\n\u003cp\u003eYes — Bridgepoint cross-reference it as PHY149-0111.\u003c\/p\u003e\n\u003ch3\u003eMy machine is cutting out early. Is the switch faulty?\u003c\/h3\u003e\n\u003cp\u003ePossibly, but check first that the machine is not genuinely overheating. A thermal switch doing its job is not a fault.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eSend us the temperature marked on your existing switch and your machine model, and we will confirm the correct part before you order.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672695239,"sku":"149-0111","price":499.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Sensor-185-Deg-Phase.jpg?v=1780550293"},{"product_id":"sensor-235deg-nason-snap-disc","title":"Sensor - 235 Deg Nason Snap Disc","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eTemperature switch, 235 °F (approximately 113 °C), Nason snap disc. HydraMaster part number 000-149-0181, cross-referenced by Bridgepoint as \u003cstrong\u003ePHY149-018\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is a sealed snap-disc thermal switch. There is nothing to adjust and nothing to calibrate — the set point is the part number.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eVerified from the Bridgepoint parts catalogue temperature control cross-reference:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCrossfire 4.4\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThat is the only machine we can name from a published cross-reference. Do not assume it carries to other Crossfire variants — the 3.7 and 4.2 are listed against different switches.\u003c\/p\u003e\n\n\u003ch2\u003eImportant — the set point is the part\u003c\/h2\u003e\n\u003cp\u003eHydraMaster use several fixed-temperature switches that look identical and are not interchangeable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sensor-185-deg-phase\"\u003e\u003cstrong\u003e149-0111\u003c\/strong\u003e — 185 °F (85 °C) — SpitFire 4.0, Crossfire 4.2, old style\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-021\u003c\/strong\u003e — 218 °F (103 °C) — CDS 4.2, 4.7, 4.6 and 4.8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-0181\u003c\/strong\u003e — 235 °F (113 °C) — Crossfire 4.4 (this switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-505\u003c\/strong\u003e — 240 °F (116 °C) — MAXX 450D and 470D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-013\u003c\/strong\u003e — 245 °F (118 °C) — Crossfire 3.7 and 4.2\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sensor-285-deg-nason\"\u003e\u003cstrong\u003e149-027\u003c\/strong\u003e — 285 °F (141 °C) — SpitFire 4.0, Boxxer 421, Crossfire 4.4, MAXX 550\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote that the Crossfire 4.4 appears against both 235 °F and 285 °F — the two switches do different jobs in the same machine. \u003cstrong\u003eRead the temperature marked on the switch you are replacing before you order.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eRead the old switch before you remove it. The set point is normally marked on the body and it is the only reliable identification.\u003c\/p\u003e\n\u003cp\u003ePhotograph the wiring and note the terminal positions. Some thermal switches are normally open and some normally closed, and getting that wrong leaves the circuit permanently made or permanently broken.\u003c\/p\u003e\n\u003cp\u003eRefit it in the same location with the same sealing arrangement. A switch that is not in proper thermal contact reads late, which defeats the purpose of fitting it.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWill it fit a Crossfire 3.7 or 4.2?\u003c\/h3\u003e\n\u003cp\u003eNot according to the cross-reference — those machines are listed against 245 °F switch 149-013 and, on old-style 4.2 machines, the 185 °F switch. Check the marking on your existing switch.\u003c\/p\u003e\n\u003ch3\u003eCan I fit a higher-rated switch?\u003c\/h3\u003e\n\u003cp\u003eNo. The set point is what protects the machine.\u003c\/p\u003e\n\u003ch3\u003eIs it adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. Fixed set point.\u003c\/p\u003e\n\u003ch3\u003eIs Nason the manufacturer?\u003c\/h3\u003e\n\u003cp\u003eYes — Nason is the switch manufacturer. Bridgepoint cross-reference the same part as PHY149-018.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eSend us the temperature marked on your existing switch and your machine model and we will confirm the correct part before you order.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672697095,"sku":"149-0181","price":402.78,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Sensor-235-Deg-Nason-Snap-Disc.jpg?v=1780550295"},{"product_id":"sensor-285-deg-nason","title":"Hydramaster Nason 285 Degree Sensor Kill Switch","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eTemperature switch, 285 °F (approximately 141 °C), Nason, 3\/8 inch NPT. HydraMaster part number 000-149-027, listed in the parts lists as \u003cem\u003eSensor, 285 °F Nason – 3\/8\" NPT\u003c\/em\u003e and cross-referenced by Bridgepoint as \u003cstrong\u003ePHY149-017\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis is the high-limit switch — the one that cuts the machine out when solution temperature reaches a point it should never reach in normal use. It is a protection device, not a control.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eNamed directly in the machine parts lists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eBoxxer 421\u003c\/strong\u003e — by-pass valve assembly, item 15\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eBoxxer 318HP\u003c\/strong\u003e — item 14\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eBoxxer 323HP\u003c\/strong\u003e — Hi-PSI manifold assembly, item 11\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eTitan 325\u003c\/strong\u003e — item 17\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso listed in the Bridgepoint temperature control cross-reference for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 4.0\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eCrossfire 4.4\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eMAXX 550\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThat is seven machines from published documentation — one of the most widely used temperature switches in the range.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSet point: 285 °F (approximately 141 °C)\u003c\/li\u003e\n\u003cli\u003eThread: 3\/8 inch NPT\u003c\/li\u003e\n\u003cli\u003eManufacturer: Nason\u003c\/li\u003e\n\u003cli\u003eBridgepoint cross-reference: PHY149-017\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eImportant — the set point is the part\u003c\/h2\u003e\n\u003cp\u003eSeveral HydraMaster temperature switches look identical and are not interchangeable:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sensor-185-deg-phase\"\u003e\u003cstrong\u003e149-0111\u003c\/strong\u003e — 185 °F — SpitFire 4.0, Crossfire 4.2, old style\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-021\u003c\/strong\u003e — 218 °F — CDS 4.2, 4.7, 4.6, 4.8\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/sensor-235deg-nason-snap-disc\"\u003e\u003cstrong\u003e149-0181\u003c\/strong\u003e — 235 °F — Crossfire 4.4\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-505\u003c\/strong\u003e — 240 °F — MAXX 450D and 470D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-013\u003c\/strong\u003e — 245 °F — Crossfire 3.7 and 4.2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e149-027\u003c\/strong\u003e — 285 °F — this switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFitting a higher-rated switch to gain running temperature is not a modification, it is the removal of a safety device.\u003c\/strong\u003e Read the temperature marked on the switch you are replacing.\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts in the same assembly\u003c\/h2\u003e\n\u003cp\u003eOn most machines this switch sits alongside temperature sender \u003cstrong\u003e149-039\u003c\/strong\u003e and RTD sensor \u003cstrong\u003e149-540\u003c\/strong\u003e, which is mounted with \u003ca href=\"\/products\/compression-3-16-x-1-4-npt-rtd\"\u003ecompression fitting 052-587\u003c\/a\u003e. The three do different jobs: the sender drives the gauge, the RTD drives the control, and this switch is the backstop.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eUse the correct sealant on the 3\/8 inch NPT thread and check the assembly drawing for your machine — HydraMaster specify sealant on these manifold drawings explicitly.\u003c\/p\u003e\n\u003cp\u003eDo not over-tighten it into a brass manifold.\u003c\/p\u003e\n\u003cp\u003ePhotograph the wiring before you disconnect it.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eMy machine keeps cutting out. Should I fit a higher switch?\u003c\/h3\u003e\n\u003cp\u003eNo. Find out why it is reaching 285 °F. A high-limit switch tripping is the machine telling you something — commonly a restriction in the solution circuit, a failed by-pass, or a diverter fault.\u003c\/p\u003e\n\u003ch3\u003eIs it adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. Fixed set point.\u003c\/p\u003e\n\u003ch3\u003eIs it the same as the temperature sender?\u003c\/h3\u003e\n\u003cp\u003eNo. The sender (149-039) drives the gauge. This is a switch that opens or closes a circuit at a fixed temperature.\u003c\/p\u003e\n\u003ch3\u003eIs it the same as the Bridgepoint part?\u003c\/h3\u003e\n\u003cp\u003eYes — PHY149-017.\u003c\/p\u003e\n\u003ch3\u003eMy machine is not on the list. Will it fit?\u003c\/h3\u003e\n\u003cp\u003eAsk us. The thread is 3\/8 inch NPT and the switch is widely used, but we are not going to claim fitment we have not verified.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eIf your high-limit switch is tripping, tell us the machine and the circumstances — we would rather help you find the cause than sell you a switch that is doing its job correctly.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672697159,"sku":"149-027","price":243.74,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/Hydramaster-Nason-285-Degree-Sensor-Kill-Switch.jpg?v=1780550295"},{"product_id":"shaft-cds-electric-clutch","title":"HydraMaster CDS Electric Clutch Shaft","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eElectric clutch shaft for the HydraMaster CDS clutch drive system. HydraMaster part number 000-150-009, listed in the parts manual as \u003cem\u003eShaft, Electric Clutch – CDS\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe shaft carries the electric clutch that drives the machine off the vehicle engine. It runs in two bearings and is keyed at both ends, so it is the part that wears when a clutch has been run with a worn bearing or a loose retaining screw.\u003c\/p\u003e\n\n\u003ch2\u003eWhere it sits in the machine\u003c\/h2\u003e\n\u003cp\u003eIt is \u003cstrong\u003eitem 7 of the CDS 4.6\/4.8 front end assembly\u003c\/strong\u003e, in the Clutch Drive System section of the CDS owner's manual (page 7-53). One per machine.\u003c\/p\u003e\n\u003cp\u003eThe parts around it, from the same assembly list:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e000-008-011\u003c\/strong\u003e — Bearing, CDS Clutch. \u003cstrong\u003eTwo\u003c\/strong\u003e per shaft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000-139-005\u003c\/strong\u003e — Ring, Snap, CDS Clutch Shaft. \u003cstrong\u003eTwo\u003c\/strong\u003e per shaft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000-077-008\u003c\/strong\u003e — Key, Woodruff, 5\/32\" × 3\/4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000-077-009\u003c\/strong\u003e — Key, Woodruff, 3\/16\" × 3\/4\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000-143-151\u003c\/strong\u003e — Screw, 5\/16\"-24UNF × 1.25\" hex head, one, retaining\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000-036-003\u003c\/strong\u003e — Clutch Assembly, 6\" poly groove\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000-109-095\u003c\/strong\u003e — Pulley, 76 mm CDS idler, Gates, with double row bearing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote the \u003cstrong\u003etwo Woodruff keys are different sizes\u003c\/strong\u003e — 5\/32 inch and 3\/16 inch. They are not interchangeable, and it is worth checking which one you have out before you order.\u003c\/p\u003e\n\n\u003ch2\u003eWorkshop advice\u003c\/h2\u003e\n\u003cp\u003eReplace the two bearings (000-008-011) and the two snap rings (000-139-005) at the same time as the shaft. A shaft rarely fails on its own — by the time the shaft is marked, the bearings that let it move have already gone, and refitting a new shaft into old bearings puts you back where you started.\u003c\/p\u003e\n\u003cp\u003eCheck both keyways while the shaft is out. A rounded keyway on the clutch end is the usual reason a clutch slips on the shaft rather than the belt slipping on the pulley, and it is easy to misdiagnose as a clutch fault.\u003c\/p\u003e\n\u003cp\u003eCheck the retaining screw torque on reassembly. A loose 5\/16\" retaining screw lets the clutch work on the shaft, and that is what chews the keyway in the first place.\u003c\/p\u003e\n\n\u003ch2\u003eWhich CDS does this fit?\u003c\/h2\u003e\n\u003cp\u003eVerified against the \u003cstrong\u003eHydraMaster CDS owner's manual\u003c\/strong\u003e, where it appears in the CDS 4.6\/4.8 front end assembly parts list.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWe have not verified it against the CDS 4.2 and 4.7.\u003c\/strong\u003e Those machines are covered by a separate, much older manual (1996–1998) which we hold as a scanned document that does not search reliably. Rather than assume the shaft carried across unchanged, we would rather you asked. Send us the model and the serial number from the machine plate and we will confirm before you order.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eDo I need the bearings as well?\u003c\/h3\u003e\n\u003cp\u003eAlmost always, yes. See the workshop advice above — fitting a new shaft into worn bearings is a short-lived repair.\u003c\/p\u003e\n\u003ch3\u003eAre the two keys the same?\u003c\/h3\u003e\n\u003cp\u003eNo. One is 5\/32 inch and the other 3\/16 inch. Check before ordering.\u003c\/p\u003e\n\u003ch3\u003eIs the clutch supplied with the shaft?\u003c\/h3\u003e\n\u003cp\u003eNo. The clutch assembly is a separate part number (000-036-003). This listing is the shaft alone.\u003c\/p\u003e\n\u003ch3\u003eThe clutch slips — is the shaft the problem?\u003c\/h3\u003e\n\u003cp\u003eIt can be. If the belt is in good order and correctly tensioned, a rounded keyway on the clutch end of the shaft will let the clutch turn on the shaft instead of driving it. Pull the clutch and look at the keyway before condemning the clutch.\u003c\/p\u003e\n\u003ch3\u003eCan you tell me what my machine takes?\u003c\/h3\u003e\n\u003cp\u003eSend us the model and serial number and we will check it against the parts list for that machine before anything is ordered.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot sure which CDS front end you have? Send us the serial number from the machine plate and we will confirm the correct shaft, bearings and keys before you order.\u003c\/p\u003e\n\n\u003cp\u003eCDS Clutch Housing Shaft.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eMore \u003ca href=\"\/collections\/hydramaster-1\"\u003eHydraMaster\u003c\/a\u003e parts and equipment, and the full range in \u003ca href=\"\/collections\/parts-maintenance\"\u003eParts \u0026amp; Maintenance\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/bearing-hiace-cds-idler\"\u003eHiace CDS 4.7 idler bearing (008-013)\u003c\/a\u003e — idler pulley bearing in the same CDS drive\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/filter-s-s-vac-pump-cds-4-7\"\u003eStainless Steel Recovery Tank Filter for Hydramaster C (049-013)\u003c\/a\u003e — CDS 4.7 recovery tank filter\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672697415,"sku":"150-009","price":483.76,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/cds_clutch_shaft.JPG?v=1780550296"},{"product_id":"sleeve-6-drive-coupler-spitfire-sidekick","title":"Sleeve #6 Drive Coupler Spitfire Sidekick","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eDrive coupler sleeve, #6. HydraMaster part number 000-152-008, listed as \u003cem\u003eSleeve, #6 Drive Coupler\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThe sleeve is the flexible element inside the jaw coupler that joins the engine shaft to the driven component. It takes the torsional shock and the small misalignment that exists in every real installation, so that the shafts and bearings do not have to.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire 3.2\u003c\/strong\u003e — engine assembly item 15\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn that assembly it works with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e039-017\u003c\/strong\u003e — Coupler, #6 × 1\" bore (item 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e020-012\u003c\/strong\u003e — Collar, SpitFire engine shaft, double screw type (item 13)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e077-006\u003c\/strong\u003e — Key, 0.25\" × 1.5\" long (item 18)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCCW's record also associates it with the SpitFire Sidekick.\u003c\/p\u003e\n\n\u003ch2\u003eImportant — HydraMaster list several coupler sleeves\u003c\/h2\u003e\n\u003cp\u003eThe sleeves are sized to the coupler, and a #6 sleeve will not serve a #7 coupler. Related parts include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e152-008\u003c\/strong\u003e — Sleeve, #6 Drive Coupler (this part)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/coupler-sleeve-7-drive-coupler\"\u003e\u003cstrong\u003e152-009\u003c\/strong\u003e — Coupler Sleeve, #7 Drive Coupler\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e152-010\u003c\/strong\u003e — Sleeve, rubber, Series 50, split — listed for the Boxxer 427\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e152-011\u003c\/strong\u003e — Coupler insert, BUCS 40 — listed for the CTS330\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCheck the coupler size stamped on the hub before you order.\u003c\/strong\u003e The sleeve number matches the coupler, not the machine.\u003c\/p\u003e\n\n\u003ch2\u003eFitting and service advice\u003c\/h2\u003e\n\u003cp\u003eInspect the sleeve whenever the coupler is exposed. A sleeve that has gone hard, cracked at the root of the legs, or shows powdered rubber in the coupler housing is finished, regardless of how it looks from the outside.\u003c\/p\u003e\n\u003cp\u003eCheck alignment while the coupler is apart. A sleeve that has worn on two legs and not the others is telling you the shafts are not in line, and a new sleeve will go the same way.\u003c\/p\u003e\n\u003cp\u003eA knock at start-up or shutdown, or a vibration that was not there before, is the usual symptom of a worn sleeve. Do not wait for it to fail completely — when a sleeve lets go, the shock goes into the bearings.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if mine is a #6?\u003c\/h3\u003e\n\u003cp\u003eThe coupler hubs are marked. If you cannot read the marking, measure the coupler and send us the figures — do not order on the assumption that a machine model implies a coupler size.\u003c\/p\u003e\n\u003ch3\u003eWill a #7 sleeve fit a #6 coupler?\u003c\/h3\u003e\n\u003cp\u003eNo.\u003c\/p\u003e\n\u003ch3\u003eDoes it come with the coupler hubs?\u003c\/h3\u003e\n\u003cp\u003eNo. The hubs are separate part numbers.\u003c\/p\u003e\n\u003ch3\u003eHow often should it be replaced?\u003c\/h3\u003e\n\u003cp\u003eOn condition. Inspect whenever the coupler is accessible, and replace at the first sign of hardening or cracking.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eNot sure which sleeve your coupler takes? Send us a photo of the coupler hub with the marking visible and we will identify it.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672702727,"sku":"152-008","price":165.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Sleeve-6-Drive-Coupler-Spitfire-Sidekick.jpg?v=1780550297"},{"product_id":"spring-hydramaster-solution-valve","title":"Spring HydraMaster Solution Valve","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eSolution valve spring for the HydraMaster stainless solution valve, listed as \u003cem\u003eSpring, HM Solution Valve\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eIt returns the valve to closed when the trigger is released. A tired spring shows up as a valve that is slow to shut off, or that weeps after the trigger is let go.\u003c\/p\u003e\n\u003ch2\u003eWhere it is fitted\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSolution valve assembly, with valve body 600-012-001 and valve stem 600-012-002\u003c\/li\u003e\n\u003cli\u003eFitted in the stainless HydraMaster solution valve 169-058\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eServicing the valve\u003c\/h2\u003e\n\u003cp\u003eIf the valve is weeping, the spring is one of three wear items. The others are the plunger o-rings — 097-010 (large, valve plunger) and 097-022 (small, flow meter) — inside the stem assembly. Replacing all three at once is the usual approach; going back in for a second o-ring costs more in downtime than the part is worth.\u003c\/p\u003e\n\u003ch2\u003eIdentifying the right part\u003c\/h2\u003e\n\u003cp\u003eCCW part codes are the HydraMaster part number with the \u003ccode\u003e000-\u003c\/code\u003e prefix removed — this item is HydraMaster P\/N \u003cstrong\u003e000-155-003\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eHydraMaster truckmounts share components across models and production years. If you are ordering for an existing machine, send us the model and serial number from the data plate and we will check it against the parts list for your machine.\u003c\/p\u003e\u003cp\u003eConfirmed against the HydraMaster \u003cstrong\u003eCDS 4.2 \/ 4.7\u003c\/strong\u003e machine assemblies and parts lists. Fitment to other HydraMaster models has not been verified from a parts list — ask us if you are ordering for a different machine.\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003eSPRING HYDRAMASTER SOLUTION VALVE\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/stem-assembly-hydramaster-solution-valve\"\u003eSolution Valve Stem Assembly (600-012-002)\u003c\/a\u003e — plunger, o-rings, keeper and snap ring\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/repair-o-ring-kit-hydramaster-solution-valve\"\u003eRepair O-Ring Kit, Solution Valve (078-019)\u003c\/a\u003e — seals only\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eSlow to shut off, or weeping — which is the spring?\u003c\/h3\u003e\n\u003cp\u003eThe spring returns the valve to closed, so a tired spring shows as slow or incomplete shut-off. Weeping while closed points at the plunger o-rings instead. If you have both symptoms, service all three wear items together.\u003c\/p\u003e\n\u003ch3\u003eCan I stretch a tired spring to get more life out of it?\u003c\/h3\u003e\n\u003cp\u003eNo. Stretching changes the rate and it will not return the valve reliably. It is a low-cost part on a valve that is opened thousands of times a day.\u003c\/p\u003e\n\u003ch3\u003eDo you stock the complete valve?\u003c\/h3\u003e\n\u003cp\u003eNot as a listed line. Send us your machine model and serial number and we will work out what you need.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672705863,"sku":"155-003","price":23.61,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/products\/Spring-HydraMaster-Solution-Valve.jpg?v=1780550297"},{"product_id":"switch-mini-liquid-level-reed","title":"Liquid Level Mini Switch","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eLiquid level mini switch. HydraMaster part number 000-157-004. It is a small reed-type level switch used where a full-size float assembly will not fit.\u003c\/p\u003e\n\n\u003ch2\u003eWhat you receive\u003c\/h2\u003e\n\u003cp\u003eThe switch as shown in the product photo: a small vertical float switch with a threaded body and attached lead wires. It is a single switch, not a float assembly with a housing or guard.\u003c\/p\u003e\n\n\u003ch2\u003eWhat it fits\u003c\/h2\u003e\n\u003cp\u003eHydraMaster Tech Support describes the application as the low water box float, \"cross fire\", on the HydraMaster \u003cstrong\u003eSpitFire\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCCW's own workshop records also list it for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eSpitFire\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eMAXX 450\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHydraMaster \u003cstrong\u003eMAXX 470\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe have not been able to locate this part number in the HydraMaster machine parts lists or the suggested spares schedule we hold, so the MAXX 450 and 470 entries rest on CCW's own workshop record rather than on a published parts list. We are recording that honestly rather than dressing it up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore you order, tell us the machine and where the switch sits\u003c\/strong\u003e and we will confirm.\u003c\/p\u003e\n\n\u003ch2\u003eDiagnosing a level switch\u003c\/h2\u003e\n\u003cp\u003eReed level switches fail in two distinct ways:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStuck closed\u003c\/strong\u003e — the machine believes the level is reached when it is not. Whatever the switch was protecting keeps running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStuck open\u003c\/strong\u003e — the machine reports a fault or refuses to run with the level perfectly normal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore condemning the switch, clean the float and the stem. Scale, fibre and detergent residue restrict float travel and produce exactly the same symptoms as a dead switch, at no cost to fix.\u003c\/p\u003e\n\u003cp\u003eThen check the connections. The switch is sealed; the terminations in a wet environment are the weak point.\u003c\/p\u003e\n\n\u003ch2\u003eFitting advice\u003c\/h2\u003e\n\u003cp\u003eNote the orientation before removal. A level switch fitted the wrong way up works backwards, and mini switches will thread in either way without complaint.\u003c\/p\u003e\n\u003cp\u003eSeal the mounting properly — a weeping level switch fitting becomes an electrical fault before it becomes a leak you notice.\u003c\/p\u003e\n\n\u003ch2\u003eRelated parts\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/switch-sidemount-inc-fittings\"\u003eSidemount Float Switch inc Fittings (157-031)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/switch-ss-float-recovery-tank\"\u003eHydraMaster Recovery Tank Float Switch (157-0801)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is in the pack?\u003c\/h3\u003e\n\u003cp\u003eThe single switch with its lead wires, as shown in the photo.\u003c\/p\u003e\n\u003ch3\u003eWill it fit my machine?\u003c\/h3\u003e\n\u003cp\u003eHydraMaster Tech Support lists it as the low water box float on the SpitFire. Our record also lists the MAXX 450\/470, but we have not been able to confirm those against a published parts list. Send us your model and we will check.\u003c\/p\u003e\n\u003ch3\u003eWhat are the electrical ratings?\u003c\/h3\u003e\n\u003cp\u003eNot stated in the documentation we hold. Ask us if you need the specification before ordering.\u003c\/p\u003e\n\u003ch3\u003eIs it normally open or normally closed?\u003c\/h3\u003e\n\u003cp\u003eNot stated. Photograph your existing wiring before you remove the old switch.\u003c\/p\u003e\n\u003ch3\u003eMy machine reports the wrong level. Is this the fix?\u003c\/h3\u003e\n\u003cp\u003eClean the float and check the connections first — both are more common causes than a failed switch.\u003c\/p\u003e\n\n\u003chr\u003e\n\u003cp\u003eSend us your machine model and a photo of the switch you are replacing and we will confirm it before you order.\u003c\/p\u003e","brand":"Hydramaster","offers":[{"title":"EACH","offer_id":50672706247,"sku":"157-004","price":291.56,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2179\/6391\/files\/157-004.png?v=1793149352"}],"url":"https:\/\/ccwonline.com.au\/collections\/pre-order-eligible.oembed?page=5","provider":"Carpet Cleaners Warehouse","version":"1.0","type":"link"}